ABAP Select data from SAP table /B364/EAVR_MP02 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /B364/EAVR_MP02 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /B364/EAVR_MP02. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /B364/EAVR_MP02 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/B364/EAVR_MP02 TYPE STANDARD TABLE OF /B364/EAVR_MP02,
      WA_/B364/EAVR_MP02 TYPE /B364/EAVR_MP02,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </B364/EAVR_MP02> TYPE /B364/EAVR_MP02.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/B364/EAVR_MP02.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /B364/EAVR_MP02
  INTO TABLE IT_/B364/EAVR_MP02.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /B364/EAVR_MP02
*  INTO TABLE @DATA(IT_/B364/EAVR_MP022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/B364/EAVR_MP02 INDEX 1 INTO DATA(WA_/B364/EAVR_MP022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/B364/EAVR_MP02 ASSIGNING </B364/EAVR_MP02>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</B364/EAVR_MP02>-KEY_AVR_MP02P = 1.
</B364/EAVR_MP02>-KEY_AVR_MP02T = 1.
</B364/EAVR_MP02>-KEY_AVR_MP02U = 1.
</B364/EAVR_MP02>-KEY_AVR_MP021 = 1.
</B364/EAVR_MP02>-KEY_AVR_MP022 = 1.
ENDLOOP.

LOOP AT IT_/B364/EAVR_MP02 INTO WA_/B364/EAVR_MP02.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/B364/EAVR_MP02-KEY_AVR_MP023, sy-vline,
WA_/B364/EAVR_MP02-KEY_AVR_MP024, sy-vline,
WA_/B364/EAVR_MP02-KEY_AVR_MP025, sy-vline,
WA_/B364/EAVR_MP02-/B364/S_ACT, sy-vline,
WA_/B364/EAVR_MP02-/B364/S_FPCA, sy-vline,
WA_/B364/EAVR_MP02-/B364/S_FASR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/B364/EAVR_MP02 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/B364/EAVR_MP02 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/B364/EAVR_MP02 INTO WA_/B364/EAVR_MP02. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/B364/EAVR_MP02_STR,
KEY_AVR_MP02P TYPE STRING,
KEY_AVR_MP02T TYPE STRING,
KEY_AVR_MP02U TYPE STRING,
KEY_AVR_MP021 TYPE STRING,
KEY_AVR_MP022 TYPE STRING,
KEY_AVR_MP023 TYPE STRING,
KEY_AVR_MP024 TYPE STRING,
KEY_AVR_MP025 TYPE STRING,
/B364/S_ACT TYPE STRING,
/B364/S_FPCA TYPE STRING,
/B364/S_FASR TYPE STRING,
/B364/S_FEACA TYPE STRING,
/B364/S_CMTS TYPE STRING,
/B364/S_FEAQTY TYPE STRING,
/B364/S_FEASR TYPE STRING,
/B364/S_FETCA TYPE STRING,
/B364/S_FETQTY TYPE STRING,
/B364/S_FETSR TYPE STRING,
/B364/S_FPSR TYPE STRING,
/B364/S_FPOC TYPE STRING,
/B364/S_ACST TYPE STRING,
/B364/S_ACTCACUR TYPE STRING,
/B364/S_ACTOBCUR TYPE STRING,
/B364/S_ACTTCUR TYPE STRING,
/B364/S_AREV TYPE STRING,
/B364/S_AREVCA TYPE STRING,
/B364/S_AREVOC TYPE STRING,
/B364/S_AREVTC TYPE STRING,
/B364/S_TCMNTCO TYPE STRING,
/B364/S_TCMNTOB TYPE STRING,
/B364/S_TCMNTS TYPE STRING,
/B364/S_TCMNTTC TYPE STRING,
/B364/S_CMACT TYPE STRING,
/B364/S_ACSTFPC TYPE STRING,
/B364/S_AREVFPC TYPE STRING,
/B364/S_TCMNTFPC TYPE STRING,
/B364/S_ATQNTY TYPE STRING,
/B364/S_FQTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/B364/EAVR_MP02_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP02P sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP02T sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP02U sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP021 sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP022 sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP023 sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP024 sy-vline
WA_/B364/EAVR_MP02_STR-KEY_AVR_MP025 sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ACT sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FPCA sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FASR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FEACA sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_CMTS sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FEAQTY sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FEASR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FETCA sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FETQTY sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FETSR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FPSR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FPOC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ACST sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ACTCACUR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ACTOBCUR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ACTTCUR sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_AREV sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_AREVCA sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_AREVOC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_AREVTC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_TCMNTCO sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_TCMNTOB sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_TCMNTS sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_TCMNTTC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_CMACT sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ACSTFPC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_AREVFPC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_TCMNTFPC sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_ATQNTY sy-vline
WA_/B364/EAVR_MP02_STR-/B364/S_FQTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.