ABAP Select data from SAP table /BCV/S_FND_UNIT_TEST_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BCV/S_FND_UNIT_TEST_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BCV/S_FND_UNIT_TEST_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /BCV/S_FND_UNIT_TEST_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/BCV/S_FND_UNIT_TEST_DATA TYPE STANDARD TABLE OF /BCV/S_FND_UNIT_TEST_DATA, WA_/BCV/S_FND_UNIT_TEST_DATA TYPE /BCV/S_FND_UNIT_TEST_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </BCV/S_FND_UNIT_TEST_DATA> TYPE /BCV/S_FND_UNIT_TEST_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/BCV/S_FND_UNIT_TEST_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /BCV/S_FND_UNIT_TEST_DATA INTO TABLE IT_/BCV/S_FND_UNIT_TEST_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /BCV/S_FND_UNIT_TEST_DATA * INTO TABLE @DATA(IT_/BCV/S_FND_UNIT_TEST_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/BCV/S_FND_UNIT_TEST_DATA INDEX 1 INTO DATA(WA_/BCV/S_FND_UNIT_TEST_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/BCV/S_FND_UNIT_TEST_DATA ASSIGNING </BCV/S_FND_UNIT_TEST_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</BCV/S_FND_UNIT_TEST_DATA>-INT4_1 = 1.
</BCV/S_FND_UNIT_TEST_DATA>-INT4_2 = 1.
</BCV/S_FND_UNIT_TEST_DATA>-INT4_3 = 1.
</BCV/S_FND_UNIT_TEST_DATA>-FLTP_1 = 1.
</BCV/S_FND_UNIT_TEST_DATA>-FLTP_2 = 1.
ENDLOOP. LOOP AT IT_/BCV/S_FND_UNIT_TEST_DATA INTO WA_/BCV/S_FND_UNIT_TEST_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/BCV/S_FND_UNIT_TEST_DATA-FLTP_3, sy-vline,
WA_/BCV/S_FND_UNIT_TEST_DATA-QUAN_1, sy-vline,
WA_/BCV/S_FND_UNIT_TEST_DATA-QUAN_2, sy-vline,
WA_/BCV/S_FND_UNIT_TEST_DATA-QUAN_3, sy-vline,
WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_1, sy-vline,
WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BCV/S_FND_UNIT_TEST_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BCV/S_FND_UNIT_TEST_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BCV/S_FND_UNIT_TEST_DATA INTO WA_/BCV/S_FND_UNIT_TEST_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field UNIT_1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_1.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_2.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-UNIT_3.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BCVTM, internal->external for field TIMS_1 CALL FUNCTION 'CONVERSION_EXIT_BCVTM_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-TIMS_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-TIMS_1.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BCVWK, internal->external for field WEEK_1 CALL FUNCTION 'CONVERSION_EXIT_BCVWK_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-WEEK_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-WEEK_1.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BCVMN, internal->external for field MON_1 CALL FUNCTION 'CONVERSION_EXIT_BCVMN_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-MON_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-MON_1.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BCVQT, internal->external for field QRT_1 CALL FUNCTION 'CONVERSION_EXIT_BCVQT_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-QRT_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-QRT_1.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BCVFP, internal->external for field FPER_1 CALL FUNCTION 'CONVERSION_EXIT_BCVFP_OUTPUT' EXPORTING input = WA_/BCV/S_FND_UNIT_TEST_DATA-FPER_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BCV/S_FND_UNIT_TEST_DATA-FPER_1.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BCV/S_FND_UNIT_TEST_DATA_STR,
INT4_1 TYPE STRING,
INT4_2 TYPE STRING,
INT4_3 TYPE STRING,
FLTP_1 TYPE STRING,
FLTP_2 TYPE STRING,
FLTP_3 TYPE STRING,
QUAN_1 TYPE STRING,
QUAN_2 TYPE STRING,
QUAN_3 TYPE STRING,
UNIT_1 TYPE STRING,
UNIT_2 TYPE STRING,
UNIT_3 TYPE STRING,
CURR_1 TYPE STRING,
CURR_2 TYPE STRING,
CURR_3 TYPE STRING,
CUKY_1 TYPE STRING,
CUKY_2 TYPE STRING,
CUKY_3 TYPE STRING,
CHAR_1 TYPE STRING,
CHAR_2 TYPE STRING,
CHAR_3 TYPE STRING,
NUMC_1 TYPE STRING,
NUMC_2 TYPE STRING,
NUMC_3 TYPE STRING,
DATS_1 TYPE STRING,
DATS_2 TYPE STRING,
DATS_3 TYPE STRING,
TIMS_1 TYPE STRING,
WEEK_1 TYPE STRING,
MON_1 TYPE STRING,
QRT_1 TYPE STRING,
FPER_1 TYPE STRING,
YEAR_1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BCV/S_FND_UNIT_TEST_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-INT4_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-INT4_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-INT4_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-FLTP_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-FLTP_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-FLTP_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-QUAN_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-QUAN_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-QUAN_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-UNIT_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-UNIT_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-UNIT_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CURR_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CURR_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CURR_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CUKY_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CUKY_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CUKY_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CHAR_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CHAR_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-CHAR_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-NUMC_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-NUMC_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-NUMC_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-DATS_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-DATS_2 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-DATS_3 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-TIMS_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-WEEK_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-MON_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-QRT_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-FPER_1 sy-vline
WA_/BCV/S_FND_UNIT_TEST_DATA_STR-YEAR_1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.