ABAP Select data from SAP table /BI0/APERS_BOD40 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BI0/APERS_BOD40 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BI0/APERS_BOD40. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BI0/APERS_BOD40 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BI0/APERS_BOD40 TYPE STANDARD TABLE OF /BI0/APERS_BOD40,
      WA_/BI0/APERS_BOD40 TYPE /BI0/APERS_BOD40,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BI0/APERS_BOD40> TYPE /BI0/APERS_BOD40.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BI0/APERS_BOD40.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BI0/APERS_BOD40
  INTO TABLE IT_/BI0/APERS_BOD40.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BI0/APERS_BOD40
*  INTO TABLE @DATA(IT_/BI0/APERS_BOD402).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BI0/APERS_BOD40 INDEX 1 INTO DATA(WA_/BI0/APERS_BOD402).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BI0/APERS_BOD40 ASSIGNING </BI0/APERS_BOD40>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BI0/APERS_BOD40>-SID = 1.
</BI0/APERS_BOD40>-SID = 1.
</BI0/APERS_BOD40>-DATAPAKID = 1.
</BI0/APERS_BOD40>-DATAPAKID = 1.
</BI0/APERS_BOD40>-RECORD = 1.
ENDLOOP.

LOOP AT IT_/BI0/APERS_BOD40 INTO WA_/BI0/APERS_BOD40.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BI0/APERS_BOD40-RECORD, sy-vline,
WA_/BI0/APERS_BOD40-TCTUSERNM, sy-vline,
WA_/BI0/APERS_BOD40-TCTUSERNM, sy-vline,
WA_/BI0/APERS_BOD40-TCTOBJVERS, sy-vline,
WA_/BI0/APERS_BOD40-TCTOBJVERS, sy-vline,
WA_/BI0/APERS_BOD40-TCTSYSID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BI0/APERS_BOD40 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BI0/APERS_BOD40 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BI0/APERS_BOD40 INTO WA_/BI0/APERS_BOD40. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TIMES, internal->external for field TCTTIMSTMP CALL FUNCTION 'CONVERSION_EXIT_TIMES_OUTPUT' EXPORTING input = WA_/BI0/APERS_BOD40-TCTTIMSTMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BI0/APERS_BOD40-TCTTIMSTMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TIMES, internal->external for field TCTTIMSTMP CALL FUNCTION 'CONVERSION_EXIT_TIMES_OUTPUT' EXPORTING input = WA_/BI0/APERS_BOD40-TCTTIMSTMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BI0/APERS_BOD40-TCTTIMSTMP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BI0/APERS_BOD40_STR,
SID TYPE STRING,
SID TYPE STRING,
DATAPAKID TYPE STRING,
DATAPAKID TYPE STRING,
RECORD TYPE STRING,
RECORD TYPE STRING,
TCTUSERNM TYPE STRING,
TCTUSERNM TYPE STRING,
TCTOBJVERS TYPE STRING,
TCTOBJVERS TYPE STRING,
TCTSYSID TYPE STRING,
TCTSYSID TYPE STRING,
TCTQUACT TYPE STRING,
TCTQUACT TYPE STRING,
TCTOBJNM TYPE STRING,
TCTOBJNM TYPE STRING,
TCTTLOGO TYPE STRING,
TCTTLOGO TYPE STRING,
RECORDMODE TYPE STRING,
RECORDMODE TYPE STRING,
TCTTIMSTMP TYPE STRING,
TCTTIMSTMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BI0/APERS_BOD40_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BI0/APERS_BOD40_STR-SID sy-vline
WA_/BI0/APERS_BOD40_STR-SID sy-vline
WA_/BI0/APERS_BOD40_STR-DATAPAKID sy-vline
WA_/BI0/APERS_BOD40_STR-DATAPAKID sy-vline
WA_/BI0/APERS_BOD40_STR-RECORD sy-vline
WA_/BI0/APERS_BOD40_STR-RECORD sy-vline
WA_/BI0/APERS_BOD40_STR-TCTUSERNM sy-vline
WA_/BI0/APERS_BOD40_STR-TCTUSERNM sy-vline
WA_/BI0/APERS_BOD40_STR-TCTOBJVERS sy-vline
WA_/BI0/APERS_BOD40_STR-TCTOBJVERS sy-vline
WA_/BI0/APERS_BOD40_STR-TCTSYSID sy-vline
WA_/BI0/APERS_BOD40_STR-TCTSYSID sy-vline
WA_/BI0/APERS_BOD40_STR-TCTQUACT sy-vline
WA_/BI0/APERS_BOD40_STR-TCTQUACT sy-vline
WA_/BI0/APERS_BOD40_STR-TCTOBJNM sy-vline
WA_/BI0/APERS_BOD40_STR-TCTOBJNM sy-vline
WA_/BI0/APERS_BOD40_STR-TCTTLOGO sy-vline
WA_/BI0/APERS_BOD40_STR-TCTTLOGO sy-vline
WA_/BI0/APERS_BOD40_STR-RECORDMODE sy-vline
WA_/BI0/APERS_BOD40_STR-RECORDMODE sy-vline
WA_/BI0/APERS_BOD40_STR-TCTTIMSTMP sy-vline
WA_/BI0/APERS_BOD40_STR-TCTTIMSTMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.