ABAP Select data from SAP table /BIC/CCTA0REBUILDING_ATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0REBUILDING_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0REBUILDING_ATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0REBUILDING_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0REBUILDING_ATTR TYPE STANDARD TABLE OF /BIC/CCTA0REBUILDING_ATTR,
      WA_/BIC/CCTA0REBUILDING_ATTR TYPE /BIC/CCTA0REBUILDING_ATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0REBUILDING_ATTR> TYPE /BIC/CCTA0REBUILDING_ATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0REBUILDING_ATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0REBUILDING_ATTR
  INTO TABLE IT_/BIC/CCTA0REBUILDING_ATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0REBUILDING_ATTR
*  INTO TABLE @DATA(IT_/BIC/CCTA0REBUILDING_ATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0REBUILDING_ATTR INDEX 1 INTO DATA(WA_/BIC/CCTA0REBUILDING_ATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0REBUILDING_ATTR ASSIGNING </BIC/CCTA0REBUILDING_ATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0REBUILDING_ATTR>-OBJNR = 1.
</BIC/CCTA0REBUILDING_ATTR>-BUKRS = 1.
</BIC/CCTA0REBUILDING_ATTR>-SWENR = 1.
</BIC/CCTA0REBUILDING_ATTR>-SGENR = 1.
</BIC/CCTA0REBUILDING_ATTR>-KEYDATE = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0REBUILDING_ATTR INTO WA_/BIC/CCTA0REBUILDING_ATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0REBUILDING_ATTR-RGEBART, sy-vline,
WA_/BIC/CCTA0REBUILDING_ATTR-JERBBAU, sy-vline,
WA_/BIC/CCTA0REBUILDING_ATTR-RGEBZUST, sy-vline,
WA_/BIC/CCTA0REBUILDING_ATTR-YBAUJAHR, sy-vline,
WA_/BIC/CCTA0REBUILDING_ATTR-YMODERN, sy-vline,
WA_/BIC/CCTA0REBUILDING_ATTR-BBAUWAKT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0REBUILDING_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0REBUILDING_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0REBUILDING_ATTR INTO WA_/BIC/CCTA0REBUILDING_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0REBUILDING_ATTR_STR,
OBJNR TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SGENR TYPE STRING,
KEYDATE TYPE STRING,
RGEBART TYPE STRING,
JERBBAU TYPE STRING,
RGEBZUST TYPE STRING,
YBAUJAHR TYPE STRING,
YMODERN TYPE STRING,
BBAUWAKT TYPE STRING,
JDENKMAL TYPE STRING,
BEINHEITW TYPE STRING,
NEINHEITW TYPE STRING,
BVERSWRT TYPE STRING,
SUNUTZA TYPE STRING,
SSTDORT TYPE STRING,
WAERS TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
PRCTR TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
POST_CODE1 TYPE STRING,
CITY1 TYPE STRING,
CITY2 TYPE STRING,
POSTALAREA TYPE STRING,
STREET TYPE STRING,
HOUSE_NUM1 TYPE STRING,
HOUSE_NUM2 TYPE STRING,
POST_CODE2 TYPE STRING,
PO_BOX TYPE STRING,
ADRZUS TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
DATEFROM TYPE STRING,
DATETO TYPE STRING,
AVAIL TYPE STRING,
OCCUP TYPE STRING,
BWSTRES1 TYPE STRING,
BWSTRES2 TYPE STRING,
BWSTREU1 TYPE STRING,
BWSTREU2 TYPE STRING,
BWSTREU3 TYPE STRING,
BWSTREU4 TYPE STRING,
BWSTREU5 TYPE STRING,
RESPONSIBLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0REBUILDING_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-OBJNR sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BUKRS sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-SWENR sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-SGENR sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-KEYDATE sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-RGEBART sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-JERBBAU sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-RGEBZUST sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-YBAUJAHR sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-YMODERN sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BBAUWAKT sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-JDENKMAL sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BEINHEITW sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-NEINHEITW sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BVERSWRT sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-SUNUTZA sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-SSTDORT sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-WAERS sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-GSBER sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-KOKRS sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-PRCTR sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-COUNTRY sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-REGION sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-POST_CODE1 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-CITY1 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-CITY2 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-POSTALAREA sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-STREET sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-HOUSE_NUM1 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-HOUSE_NUM2 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-POST_CODE2 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-PO_BOX sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-ADRZUS sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-VALIDFROM sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-VALIDTO sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-DATEFROM sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-DATETO sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-AVAIL sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-OCCUP sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTRES1 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTRES2 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTREU1 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTREU2 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTREU3 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTREU4 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-BWSTREU5 sy-vline
WA_/BIC/CCTA0REBUILDING_ATTR_STR-RESPONSIBLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.