ABAP Select data from SAP table /BIC/CS80RSTT_O01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CS80RSTT_O01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CS80RSTT_O01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CS80RSTT_O01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CS80RSTT_O01 TYPE STANDARD TABLE OF /BIC/CS80RSTT_O01,
      WA_/BIC/CS80RSTT_O01 TYPE /BIC/CS80RSTT_O01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CS80RSTT_O01> TYPE /BIC/CS80RSTT_O01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CS80RSTT_O01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CS80RSTT_O01
  INTO TABLE IT_/BIC/CS80RSTT_O01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CS80RSTT_O01
*  INTO TABLE @DATA(IT_/BIC/CS80RSTT_O012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CS80RSTT_O01 INDEX 1 INTO DATA(WA_/BIC/CS80RSTT_O012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CS80RSTT_O01 ASSIGNING </BIC/CS80RSTT_O01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CS80RSTT_O01>-CALDAY = 1.
</BIC/CS80RSTT_O01>-RECORDMODE = 1.
</BIC/CS80RSTT_O01>-RSTT_JGUID = 1.
</BIC/CS80RSTT_O01>-RSTT_LGUID = 1.
</BIC/CS80RSTT_O01>-RSTT_LOGNR = 1.
ENDLOOP.

LOOP AT IT_/BIC/CS80RSTT_O01 INTO WA_/BIC/CS80RSTT_O01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CS80RSTT_O01-RSTT_PGUID, sy-vline,
WA_/BIC/CS80RSTT_O01-RSTT_RTIML, sy-vline,
WA_/BIC/CS80RSTT_O01-RSTT_TAREA, sy-vline,
WA_/BIC/CS80RSTT_O01-RSTT_TTYPE, sy-vline,
WA_/BIC/CS80RSTT_O01-RSTT_USER, sy-vline,
WA_/BIC/CS80RSTT_O01-TIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CS80RSTT_O01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CS80RSTT_O01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CS80RSTT_O01 INTO WA_/BIC/CS80RSTT_O01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RSTT_JGUID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_JGUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_JGUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSTT_LGUID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_LGUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_LGUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSTT_LOGNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_LOGNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_LOGNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSTT_PGUID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_PGUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_PGUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSTT_TAREA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_TAREA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_TAREA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSTT_TTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_TTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_TTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSTT_USER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BIC/CS80RSTT_O01-RSTT_USER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BIC/CS80RSTT_O01-RSTT_USER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CS80RSTT_O01_STR,
CALDAY TYPE STRING,
RECORDMODE TYPE STRING,
RSTT_JGUID TYPE STRING,
RSTT_LGUID TYPE STRING,
RSTT_LOGNR TYPE STRING,
RSTT_PGUID TYPE STRING,
RSTT_RTIML TYPE STRING,
RSTT_TAREA TYPE STRING,
RSTT_TTYPE TYPE STRING,
RSTT_USER TYPE STRING,
TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CS80RSTT_O01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CS80RSTT_O01_STR-CALDAY sy-vline
WA_/BIC/CS80RSTT_O01_STR-RECORDMODE sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_JGUID sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_LGUID sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_LOGNR sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_PGUID sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_RTIML sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_TAREA sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_TTYPE sy-vline
WA_/BIC/CS80RSTT_O01_STR-RSTT_USER sy-vline
WA_/BIC/CS80RSTT_O01_STR-TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.