ABAP Select data from SAP table /CFG/S_COMP_FLD_ATTRIBUTES into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /CFG/S_COMP_FLD_ATTRIBUTES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /CFG/S_COMP_FLD_ATTRIBUTES. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /CFG/S_COMP_FLD_ATTRIBUTES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/CFG/S_COMP_FLD_ATTRIBUTES TYPE STANDARD TABLE OF /CFG/S_COMP_FLD_ATTRIBUTES, WA_/CFG/S_COMP_FLD_ATTRIBUTES TYPE /CFG/S_COMP_FLD_ATTRIBUTES, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </CFG/S_COMP_FLD_ATTRIBUTES> TYPE /CFG/S_COMP_FLD_ATTRIBUTES. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/CFG/S_COMP_FLD_ATTRIBUTES. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /CFG/S_COMP_FLD_ATTRIBUTES INTO TABLE IT_/CFG/S_COMP_FLD_ATTRIBUTES. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /CFG/S_COMP_FLD_ATTRIBUTES * INTO TABLE @DATA(IT_/CFG/S_COMP_FLD_ATTRIBUTES2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/CFG/S_COMP_FLD_ATTRIBUTES INDEX 1 INTO DATA(WA_/CFG/S_COMP_FLD_ATTRIBUTES2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/CFG/S_COMP_FLD_ATTRIBUTES ASSIGNING </CFG/S_COMP_FLD_ATTRIBUTES>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</CFG/S_COMP_FLD_ATTRIBUTES>-FLD_TYPE = 1.
</CFG/S_COMP_FLD_ATTRIBUTES>-ALIAS_FLD = 1.
</CFG/S_COMP_FLD_ATTRIBUTES>-ALIAS_NAME = 1.
</CFG/S_COMP_FLD_ATTRIBUTES>-SEMANTICS = 1.
</CFG/S_COMP_FLD_ATTRIBUTES>-VISIBILITY = 1.
ENDLOOP. LOOP AT IT_/CFG/S_COMP_FLD_ATTRIBUTES INTO WA_/CFG/S_COMP_FLD_ATTRIBUTES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/CFG/S_COMP_FLD_ATTRIBUTES-EXCLUDE_FROM_CORE, sy-vline,
WA_/CFG/S_COMP_FLD_ATTRIBUTES-DISPLAY_ORDER, sy-vline,
WA_/CFG/S_COMP_FLD_ATTRIBUTES-RELEVANCE, sy-vline,
WA_/CFG/S_COMP_FLD_ATTRIBUTES-GENERATOR, sy-vline,
WA_/CFG/S_COMP_FLD_ATTRIBUTES-CONSTRAINT_FLD, sy-vline,
WA_/CFG/S_COMP_FLD_ATTRIBUTES-CONT_CLASS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/CFG/S_COMP_FLD_ATTRIBUTES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/CFG/S_COMP_FLD_ATTRIBUTES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/CFG/S_COMP_FLD_ATTRIBUTES INTO WA_/CFG/S_COMP_FLD_ATTRIBUTES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/CFG/S_COMP_FLD_ATTRIBUTES_STR,
FLD_TYPE TYPE STRING,
ALIAS_FLD TYPE STRING,
ALIAS_NAME TYPE STRING,
SEMANTICS TYPE STRING,
VISIBILITY TYPE STRING,
EXCLUDE_FROM_CORE TYPE STRING,
DISPLAY_ORDER TYPE STRING,
RELEVANCE TYPE STRING,
GENERATOR TYPE STRING,
CONSTRAINT_FLD TYPE STRING,
CONT_CLASS TYPE STRING,
CONT_USAGE TYPE STRING,
MAY_MODIFY TYPE STRING,
KEY_FIELD TYPE STRING,
LOC_EXPR TYPE STRING,
REVIEW_MODIFICATIONS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-FLD_TYPE sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-ALIAS_FLD sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-ALIAS_NAME sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-SEMANTICS sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-VISIBILITY sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-EXCLUDE_FROM_CORE sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-DISPLAY_ORDER sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-RELEVANCE sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-GENERATOR sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-CONSTRAINT_FLD sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-CONT_CLASS sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-CONT_USAGE sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-MAY_MODIFY sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-KEY_FIELD sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-LOC_EXPR sy-vline
WA_/CFG/S_COMP_FLD_ATTRIBUTES_STR-REVIEW_MODIFICATIONS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.