ABAP Select data from SAP table /CUM/CU_CLASS_IO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /CUM/CU_CLASS_IO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /CUM/CU_CLASS_IO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /CUM/CU_CLASS_IO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/CUM/CU_CLASS_IO TYPE STANDARD TABLE OF /CUM/CU_CLASS_IO, WA_/CUM/CU_CLASS_IO TYPE /CUM/CU_CLASS_IO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </CUM/CU_CLASS_IO> TYPE /CUM/CU_CLASS_IO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/CUM/CU_CLASS_IO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /CUM/CU_CLASS_IO INTO TABLE IT_/CUM/CU_CLASS_IO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /CUM/CU_CLASS_IO * INTO TABLE @DATA(IT_/CUM/CU_CLASS_IO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/CUM/CU_CLASS_IO INDEX 1 INTO DATA(WA_/CUM/CU_CLASS_IO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/CUM/CU_CLASS_IO ASSIGNING </CUM/CU_CLASS_IO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</CUM/CU_CLASS_IO>-CU_FUNCT = 1.
</CUM/CU_CLASS_IO>-CU_CLASS = 1.
</CUM/CU_CLASS_IO>-CU_ACTION = 1.
</CUM/CU_CLASS_IO>-CU_SERVICE = 1.
</CUM/CU_CLASS_IO>-CU_TYPE = 1.
ENDLOOP. LOOP AT IT_/CUM/CU_CLASS_IO INTO WA_/CUM/CU_CLASS_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/CUM/CU_CLASS_IO-FUNCT_TXT, sy-vline,
WA_/CUM/CU_CLASS_IO-CLASS_TXT, sy-vline,
WA_/CUM/CU_CLASS_IO-ACTION_TXT, sy-vline,
WA_/CUM/CU_CLASS_IO-SRVCE_TXT, sy-vline,
WA_/CUM/CU_CLASS_IO-TYPE_TXT, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/CUM/CU_CLASS_IO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/CUM/CU_CLASS_IO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/CUM/CU_CLASS_IO INTO WA_/CUM/CU_CLASS_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/CUM/CU_CLASS_IO_STR,
CU_FUNCT TYPE STRING,
CU_CLASS TYPE STRING,
CU_ACTION TYPE STRING,
CU_SERVICE TYPE STRING,
CU_TYPE TYPE STRING,
FUNCT_TXT TYPE STRING,
CLASS_TXT TYPE STRING,
ACTION_TXT TYPE STRING,
SRVCE_TXT TYPE STRING,
TYPE_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/CUM/CU_CLASS_IO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/CUM/CU_CLASS_IO_STR-CU_FUNCT sy-vline
WA_/CUM/CU_CLASS_IO_STR-CU_CLASS sy-vline
WA_/CUM/CU_CLASS_IO_STR-CU_ACTION sy-vline
WA_/CUM/CU_CLASS_IO_STR-CU_SERVICE sy-vline
WA_/CUM/CU_CLASS_IO_STR-CU_TYPE sy-vline
WA_/CUM/CU_CLASS_IO_STR-FUNCT_TXT sy-vline
WA_/CUM/CU_CLASS_IO_STR-CLASS_TXT sy-vline
WA_/CUM/CU_CLASS_IO_STR-ACTION_TXT sy-vline
WA_/CUM/CU_CLASS_IO_STR-SRVCE_TXT sy-vline
WA_/CUM/CU_CLASS_IO_STR-TYPE_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.