ABAP Select data from SAP table /CWM/HUSTOCKCOMP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /CWM/HUSTOCKCOMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /CWM/HUSTOCKCOMP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /CWM/HUSTOCKCOMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/CWM/HUSTOCKCOMP TYPE STANDARD TABLE OF /CWM/HUSTOCKCOMP, WA_/CWM/HUSTOCKCOMP TYPE /CWM/HUSTOCKCOMP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </CWM/HUSTOCKCOMP> TYPE /CWM/HUSTOCKCOMP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/CWM/HUSTOCKCOMP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /CWM/HUSTOCKCOMP INTO TABLE IT_/CWM/HUSTOCKCOMP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /CWM/HUSTOCKCOMP * INTO TABLE @DATA(IT_/CWM/HUSTOCKCOMP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/CWM/HUSTOCKCOMP INDEX 1 INTO DATA(WA_/CWM/HUSTOCKCOMP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/CWM/HUSTOCKCOMP ASSIGNING </CWM/HUSTOCKCOMP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</CWM/HUSTOCKCOMP>-HU_EXID = 1.
</CWM/HUSTOCKCOMP>-LE_EXISTS = 1.
</CWM/HUSTOCKCOMP>-HU_EXISTS = 1.
</CWM/HUSTOCKCOMP>-MATNR = 1.
</CWM/HUSTOCKCOMP>-WERKS = 1.
ENDLOOP. LOOP AT IT_/CWM/HUSTOCKCOMP INTO WA_/CWM/HUSTOCKCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/CWM/HUSTOCKCOMP-LGORT, sy-vline,
WA_/CWM/HUSTOCKCOMP-CHARG, sy-vline,
WA_/CWM/HUSTOCKCOMP-BESTQ, sy-vline,
WA_/CWM/HUSTOCKCOMP-ANZSN, sy-vline,
WA_/CWM/HUSTOCKCOMP-SOBKZ, sy-vline,
WA_/CWM/HUSTOCKCOMP-SONUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/CWM/HUSTOCKCOMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/CWM/HUSTOCKCOMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/CWM/HUSTOCKCOMP INTO WA_/CWM/HUSTOCKCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field HU_EXID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/CWM/HUSTOCKCOMP-HU_EXID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/CWM/HUSTOCKCOMP-HU_EXID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/CWM/HUSTOCKCOMP-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/CWM/HUSTOCKCOMP-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SONUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/CWM/HUSTOCKCOMP-SONUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/CWM/HUSTOCKCOMP-SONUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field /CWM/VEMEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/CWM/HUSTOCKCOMP-/CWM/VEMEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/CWM/HUSTOCKCOMP-/CWM/VEMEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/CWM/HUSTOCKCOMP_STR,
HU_EXID TYPE STRING,
LE_EXISTS TYPE STRING,
HU_EXISTS TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
BESTQ TYPE STRING,
ANZSN TYPE STRING,
SOBKZ TYPE STRING,
SONUM TYPE STRING,
QUAN_HU TYPE STRING,
QUAN_IM TYPE STRING,
QUAN_DIFF TYPE STRING,
/CWM/VEMEH TYPE STRING,
LGNUM TYPE STRING,
LGTYP TYPE STRING,
LGPLA TYPE STRING,
EXPAND TYPE STRING,
SELKZ TYPE STRING,
AENDB_LE TYPE STRING,
MSGKZ TYPE STRING,
MSG_TABLE TYPE STRING,
ICON TYPE STRING,
READ_TABLES TYPE STRING,END OF T_EKKO_STR. DATA: WA_/CWM/HUSTOCKCOMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/CWM/HUSTOCKCOMP_STR-HU_EXID sy-vline
WA_/CWM/HUSTOCKCOMP_STR-LE_EXISTS sy-vline
WA_/CWM/HUSTOCKCOMP_STR-HU_EXISTS sy-vline
WA_/CWM/HUSTOCKCOMP_STR-MATNR sy-vline
WA_/CWM/HUSTOCKCOMP_STR-WERKS sy-vline
WA_/CWM/HUSTOCKCOMP_STR-LGORT sy-vline
WA_/CWM/HUSTOCKCOMP_STR-CHARG sy-vline
WA_/CWM/HUSTOCKCOMP_STR-BESTQ sy-vline
WA_/CWM/HUSTOCKCOMP_STR-ANZSN sy-vline
WA_/CWM/HUSTOCKCOMP_STR-SOBKZ sy-vline
WA_/CWM/HUSTOCKCOMP_STR-SONUM sy-vline
WA_/CWM/HUSTOCKCOMP_STR-QUAN_HU sy-vline
WA_/CWM/HUSTOCKCOMP_STR-QUAN_IM sy-vline
WA_/CWM/HUSTOCKCOMP_STR-QUAN_DIFF sy-vline
WA_/CWM/HUSTOCKCOMP_STR-/CWM/VEMEH sy-vline
WA_/CWM/HUSTOCKCOMP_STR-LGNUM sy-vline
WA_/CWM/HUSTOCKCOMP_STR-LGTYP sy-vline
WA_/CWM/HUSTOCKCOMP_STR-LGPLA sy-vline
WA_/CWM/HUSTOCKCOMP_STR-EXPAND sy-vline
WA_/CWM/HUSTOCKCOMP_STR-SELKZ sy-vline
WA_/CWM/HUSTOCKCOMP_STR-AENDB_LE sy-vline
WA_/CWM/HUSTOCKCOMP_STR-MSGKZ sy-vline
WA_/CWM/HUSTOCKCOMP_STR-MSG_TABLE sy-vline
WA_/CWM/HUSTOCKCOMP_STR-ICON sy-vline
WA_/CWM/HUSTOCKCOMP_STR-READ_TABLES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.