ABAP Select data from SAP table /EACC/T_DCCHECK into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /EACC/T_DCCHECK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /EACC/T_DCCHECK. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /EACC/T_DCCHECK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/EACC/T_DCCHECK TYPE STANDARD TABLE OF /EACC/T_DCCHECK, WA_/EACC/T_DCCHECK TYPE /EACC/T_DCCHECK, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </EACC/T_DCCHECK> TYPE /EACC/T_DCCHECK. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/EACC/T_DCCHECK. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /EACC/T_DCCHECK INTO TABLE IT_/EACC/T_DCCHECK. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /EACC/T_DCCHECK * INTO TABLE @DATA(IT_/EACC/T_DCCHECK2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/EACC/T_DCCHECK INDEX 1 INTO DATA(WA_/EACC/T_DCCHECK2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/EACC/T_DCCHECK ASSIGNING </EACC/T_DCCHECK>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</EACC/T_DCCHECK>-CLIENT = 1.
</EACC/T_DCCHECK>-ACC_SYSTEM = 1.
</EACC/T_DCCHECK>-ACC_BUS_TR_CAT = 1.
</EACC/T_DCCHECK>-FIELDNAME = 1.
</EACC/T_DCCHECK>-CHECK_ORDER = 1.
ENDLOOP. LOOP AT IT_/EACC/T_DCCHECK INTO WA_/EACC/T_DCCHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/EACC/T_DCCHECK-X_HEAD, sy-vline,
WA_/EACC/T_DCCHECK-X_OBLIGATORY, sy-vline,
WA_/EACC/T_DCCHECK-X_MD_CHECKS, sy-vline,
WA_/EACC/T_DCCHECK-X_MD_INIT, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/EACC/T_DCCHECK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/EACC/T_DCCHECK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/EACC/T_DCCHECK INTO WA_/EACC/T_DCCHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field ACC_BUS_TR_CAT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/EACC/T_DCCHECK-ACC_BUS_TR_CAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/EACC/T_DCCHECK-ACC_BUS_TR_CAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/EACC/T_DCCHECK_STR,
CLIENT TYPE STRING,
ACC_SYSTEM TYPE STRING,
ACC_BUS_TR_CAT TYPE STRING,
FIELDNAME TYPE STRING,
CHECK_ORDER TYPE STRING,
X_HEAD TYPE STRING,
X_OBLIGATORY TYPE STRING,
X_MD_CHECKS TYPE STRING,
X_MD_INIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/EACC/T_DCCHECK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/EACC/T_DCCHECK_STR-CLIENT sy-vline
WA_/EACC/T_DCCHECK_STR-ACC_SYSTEM sy-vline
WA_/EACC/T_DCCHECK_STR-ACC_BUS_TR_CAT sy-vline
WA_/EACC/T_DCCHECK_STR-FIELDNAME sy-vline
WA_/EACC/T_DCCHECK_STR-CHECK_ORDER sy-vline
WA_/EACC/T_DCCHECK_STR-X_HEAD sy-vline
WA_/EACC/T_DCCHECK_STR-X_OBLIGATORY sy-vline
WA_/EACC/T_DCCHECK_STR-X_MD_CHECKS sy-vline
WA_/EACC/T_DCCHECK_STR-X_MD_INIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.