ABAP Select data from SAP table /GRCPI/GRIA_S_MMIMCTR_07T2_1I into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /GRCPI/GRIA_S_MMIMCTR_07T2_1I table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /GRCPI/GRIA_S_MMIMCTR_07T2_1I. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /GRCPI/GRIA_S_MMIMCTR_07T2_1I table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I TYPE STANDARD TABLE OF /GRCPI/GRIA_S_MMIMCTR_07T2_1I,
      WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I TYPE /GRCPI/GRIA_S_MMIMCTR_07T2_1I,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </GRCPI/GRIA_S_MMIMCTR_07T2_1I> TYPE /GRCPI/GRIA_S_MMIMCTR_07T2_1I.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/GRCPI/GRIA_S_MMIMCTR_07T2_1I.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /GRCPI/GRIA_S_MMIMCTR_07T2_1I
  INTO TABLE IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /GRCPI/GRIA_S_MMIMCTR_07T2_1I
*  INTO TABLE @DATA(IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I INDEX 1 INTO DATA(WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I ASSIGNING </GRCPI/GRIA_S_MMIMCTR_07T2_1I>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</GRCPI/GRIA_S_MMIMCTR_07T2_1I>-BUKRS = 1.
</GRCPI/GRIA_S_MMIMCTR_07T2_1I>-BUTXT = 1.
</GRCPI/GRIA_S_MMIMCTR_07T2_1I>-IBLNR = 1.
</GRCPI/GRIA_S_MMIMCTR_07T2_1I>-ZEILI = 1.
</GRCPI/GRIA_S_MMIMCTR_07T2_1I>-GJAHR = 1.
ENDLOOP.

LOOP AT IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I INTO WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-WERKS, sy-vline,
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-NAME1, sy-vline,
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-BUDAT, sy-vline,
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-MATNR, sy-vline,
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-WRTBM, sy-vline,
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-DMBTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/GRCPI/GRIA_S_MMIMCTR_07T2_1I TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/GRCPI/GRIA_S_MMIMCTR_07T2_1I INTO WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field IBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-IBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-IBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
IBLNR TYPE STRING,
ZEILI TYPE STRING,
GJAHR TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
BUDAT TYPE STRING,
MATNR TYPE STRING,
WRTBM TYPE STRING,
DMBTR TYPE STRING,
WAERS TYPE STRING,
VARIANCE TYPE STRING,
INVPR TYPE STRING,
USNAD TYPE STRING,
BNAME TYPE STRING,
MAXEB TYPE STRING,
ISEG_DMBTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-BUKRS sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-BUTXT sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-IBLNR sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-ZEILI sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-GJAHR sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-WERKS sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-NAME1 sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-BUDAT sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-MATNR sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-WRTBM sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-DMBTR sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-WAERS sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-VARIANCE sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-INVPR sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-USNAD sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-BNAME sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-MAXEB sy-vline
WA_/GRCPI/GRIA_S_MMIMCTR_07T2_1I_STR-ISEG_DMBTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.