ABAP Select data from SAP table /ISDFPS/151PM_BOM_ITEM into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/151PM_BOM_ITEM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/151PM_BOM_ITEM. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /ISDFPS/151PM_BOM_ITEM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/ISDFPS/151PM_BOM_ITEM TYPE STANDARD TABLE OF /ISDFPS/151PM_BOM_ITEM, WA_/ISDFPS/151PM_BOM_ITEM TYPE /ISDFPS/151PM_BOM_ITEM, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </ISDFPS/151PM_BOM_ITEM> TYPE /ISDFPS/151PM_BOM_ITEM. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/151PM_BOM_ITEM. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /ISDFPS/151PM_BOM_ITEM INTO TABLE IT_/ISDFPS/151PM_BOM_ITEM. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /ISDFPS/151PM_BOM_ITEM * INTO TABLE @DATA(IT_/ISDFPS/151PM_BOM_ITEM2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/ISDFPS/151PM_BOM_ITEM INDEX 1 INTO DATA(WA_/ISDFPS/151PM_BOM_ITEM2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/ISDFPS/151PM_BOM_ITEM ASSIGNING </ISDFPS/151PM_BOM_ITEM>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/151PM_BOM_ITEM>-MATNR = 1.
</ISDFPS/151PM_BOM_ITEM>-WERKS = 1.
</ISDFPS/151PM_BOM_ITEM>-STLAN = 1.
</ISDFPS/151PM_BOM_ITEM>-STLNR = 1.
</ISDFPS/151PM_BOM_ITEM>-STLAL = 1.
ENDLOOP. LOOP AT IT_/ISDFPS/151PM_BOM_ITEM INTO WA_/ISDFPS/151PM_BOM_ITEM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/ISDFPS/151PM_BOM_ITEM-ITEM_CATEG, sy-vline,
WA_/ISDFPS/151PM_BOM_ITEM-ITEM_NO, sy-vline,
WA_/ISDFPS/151PM_BOM_ITEM-COMPONENT, sy-vline,
WA_/ISDFPS/151PM_BOM_ITEM-COMP_QTY, sy-vline,
WA_/ISDFPS/151PM_BOM_ITEM-COMP_UNIT, sy-vline,
WA_/ISDFPS/151PM_BOM_ITEM-FIXED_QTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/151PM_BOM_ITEM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/151PM_BOM_ITEM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/151PM_BOM_ITEM INTO WA_/ISDFPS/151PM_BOM_ITEM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field ITEM_NO CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-ITEM_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-ITEM_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EHSMA, internal->external for field COMPONENT CALL FUNCTION 'CONVERSION_EXIT_EHSMA_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-COMPONENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-COMPONENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field COMP_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-COMP_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-COMP_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field BOM_ALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/151PM_BOM_ITEM-BOM_ALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/151PM_BOM_ITEM-BOM_ALT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/151PM_BOM_ITEM_STR,
MATNR TYPE STRING,
WERKS TYPE STRING,
STLAN TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
ITEM_CATEG TYPE STRING,
ITEM_NO TYPE STRING,
COMPONENT TYPE STRING,
COMP_QTY TYPE STRING,
COMP_UNIT TYPE STRING,
FIXED_QTY TYPE STRING,
ITEM_NODE TYPE STRING,
VALID_TO TYPE STRING,
BOM_ALT TYPE STRING,
FLDELETE TYPE STRING,
REC_ALLOWD TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/151PM_BOM_ITEM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-MATNR sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-WERKS sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-STLAN sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-STLNR sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-STLAL sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-ITEM_CATEG sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-ITEM_NO sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-COMPONENT sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-COMP_QTY sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-COMP_UNIT sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-FIXED_QTY sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-ITEM_NODE sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-VALID_TO sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-BOM_ALT sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-FLDELETE sy-vline
WA_/ISDFPS/151PM_BOM_ITEM_STR-REC_ALLOWD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.