ABAP Select data from SAP table /ISDFPS/OM_REF_ALV6 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/OM_REF_ALV6 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/OM_REF_ALV6. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /ISDFPS/OM_REF_ALV6 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/ISDFPS/OM_REF_ALV6 TYPE STANDARD TABLE OF /ISDFPS/OM_REF_ALV6, WA_/ISDFPS/OM_REF_ALV6 TYPE /ISDFPS/OM_REF_ALV6, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </ISDFPS/OM_REF_ALV6> TYPE /ISDFPS/OM_REF_ALV6. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/OM_REF_ALV6. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /ISDFPS/OM_REF_ALV6 INTO TABLE IT_/ISDFPS/OM_REF_ALV6. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /ISDFPS/OM_REF_ALV6 * INTO TABLE @DATA(IT_/ISDFPS/OM_REF_ALV62). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/ISDFPS/OM_REF_ALV6 INDEX 1 INTO DATA(WA_/ISDFPS/OM_REF_ALV62). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/ISDFPS/OM_REF_ALV6 ASSIGNING </ISDFPS/OM_REF_ALV6>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/OM_REF_ALV6>-ICON_O_ORIGIN = 1.
</ISDFPS/OM_REF_ALV6>-OBJID_OA = 1.
</ISDFPS/OM_REF_ALV6>-OTYPE_OA = 1.
</ISDFPS/OM_REF_ALV6>-ISTAT_OA = 1.
</ISDFPS/OM_REF_ALV6>-STEXT_ISTAT_OA = 1.
ENDLOOP. LOOP AT IT_/ISDFPS/OM_REF_ALV6 INTO WA_/ISDFPS/OM_REF_ALV6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/ISDFPS/OM_REF_ALV6-BEGDA_OA, sy-vline,
WA_/ISDFPS/OM_REF_ALV6-ENDDA_OA, sy-vline,
WA_/ISDFPS/OM_REF_ALV6-SHORT_OA, sy-vline,
WA_/ISDFPS/OM_REF_ALV6-STEXT_OA, sy-vline,
WA_/ISDFPS/OM_REF_ALV6-ICON_O_ORIGIN_KOSTL, sy-vline,
WA_/ISDFPS/OM_REF_ALV6-KOSTL_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/OM_REF_ALV6 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/OM_REF_ALV6 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/OM_REF_ALV6 INTO WA_/ISDFPS/OM_REF_ALV6. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field KOSTL_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/OM_REF_ALV6-KOSTL_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/OM_REF_ALV6-KOSTL_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PRCTR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/OM_REF_ALV6-PRCTR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/OM_REF_ALV6-PRCTR_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSN, internal->external for field WBS_ID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_/ISDFPS/OM_REF_ALV6-WBS_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/OM_REF_ALV6-WBS_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/OM_REF_ALV6_STR,
ICON_O_ORIGIN TYPE STRING,
OBJID_OA TYPE STRING,
OTYPE_OA TYPE STRING,
ISTAT_OA TYPE STRING,
STEXT_ISTAT_OA TYPE STRING,
BEGDA_OA TYPE STRING,
ENDDA_OA TYPE STRING,
SHORT_OA TYPE STRING,
STEXT_OA TYPE STRING,
ICON_O_ORIGIN_KOSTL TYPE STRING,
KOSTL_ID TYPE STRING,
KOSTL_TEXT TYPE STRING,
ICON_O_ORIGIN_FISTL TYPE STRING,
FISTL_ID TYPE STRING,
FISTL_TEXT TYPE STRING,
ICON_O_ORIGIN_PRCTR TYPE STRING,
PRCTR_ID TYPE STRING,
PRCTR_TEXT TYPE STRING,
ICON_O_ORIGIN_WBS TYPE STRING,
WBS_ID TYPE STRING,
WBS_TEXT TYPE STRING,
OBJID_RT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/OM_REF_ALV6_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ICON_O_ORIGIN sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-OBJID_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-OTYPE_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ISTAT_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-STEXT_ISTAT_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-BEGDA_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ENDDA_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-SHORT_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-STEXT_OA sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ICON_O_ORIGIN_KOSTL sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-KOSTL_ID sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-KOSTL_TEXT sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ICON_O_ORIGIN_FISTL sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-FISTL_ID sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-FISTL_TEXT sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ICON_O_ORIGIN_PRCTR sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-PRCTR_ID sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-PRCTR_TEXT sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-ICON_O_ORIGIN_WBS sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-WBS_ID sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-WBS_TEXT sy-vline
WA_/ISDFPS/OM_REF_ALV6_STR-OBJID_RT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.