ABAP Select data from SAP table /ISDFPS/S_BRF_FOX_PM_NOTIF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ISDFPS/S_BRF_FOX_PM_NOTIF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ISDFPS/S_BRF_FOX_PM_NOTIF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /ISDFPS/S_BRF_FOX_PM_NOTIF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/ISDFPS/S_BRF_FOX_PM_NOTIF TYPE STANDARD TABLE OF /ISDFPS/S_BRF_FOX_PM_NOTIF, WA_/ISDFPS/S_BRF_FOX_PM_NOTIF TYPE /ISDFPS/S_BRF_FOX_PM_NOTIF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </ISDFPS/S_BRF_FOX_PM_NOTIF> TYPE /ISDFPS/S_BRF_FOX_PM_NOTIF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/ISDFPS/S_BRF_FOX_PM_NOTIF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /ISDFPS/S_BRF_FOX_PM_NOTIF INTO TABLE IT_/ISDFPS/S_BRF_FOX_PM_NOTIF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /ISDFPS/S_BRF_FOX_PM_NOTIF * INTO TABLE @DATA(IT_/ISDFPS/S_BRF_FOX_PM_NOTIF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/ISDFPS/S_BRF_FOX_PM_NOTIF INDEX 1 INTO DATA(WA_/ISDFPS/S_BRF_FOX_PM_NOTIF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/ISDFPS/S_BRF_FOX_PM_NOTIF ASSIGNING </ISDFPS/S_BRF_FOX_PM_NOTIF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</ISDFPS/S_BRF_FOX_PM_NOTIF>-QMNUM = 1.
</ISDFPS/S_BRF_FOX_PM_NOTIF>-QMART = 1.
</ISDFPS/S_BRF_FOX_PM_NOTIF>-QMDAT = 1.
</ISDFPS/S_BRF_FOX_PM_NOTIF>-AUSVN = 1.
</ISDFPS/S_BRF_FOX_PM_NOTIF>-SWERK = 1.
ENDLOOP. LOOP AT IT_/ISDFPS/S_BRF_FOX_PM_NOTIF INTO WA_/ISDFPS/S_BRF_FOX_PM_NOTIF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-IWERK, sy-vline,
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-GEWRK, sy-vline,
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-INGRP, sy-vline,
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-REVNR, sy-vline,
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-SYS_STATUS_TAB, sy-vline,
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-USR_STATUS_SCHEMA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ISDFPS/S_BRF_FOX_PM_NOTIF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ISDFPS/S_BRF_FOX_PM_NOTIF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ISDFPS/S_BRF_FOX_PM_NOTIF INTO WA_/ISDFPS/S_BRF_FOX_PM_NOTIF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-QMNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-TPLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ISDFPS/S_BRF_FOX_PM_NOTIF-EQUNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR,
QMNUM TYPE STRING,
QMART TYPE STRING,
QMDAT TYPE STRING,
AUSVN TYPE STRING,
SWERK TYPE STRING,
IWERK TYPE STRING,
GEWRK TYPE STRING,
INGRP TYPE STRING,
REVNR TYPE STRING,
SYS_STATUS_TAB TYPE STRING,
USR_STATUS_SCHEMA TYPE STRING,
USR_STATUS_TAB TYPE STRING,
TPLNR TYPE STRING,
TPL_DEL_FLG TYPE STRING,
EQUNR TYPE STRING,
EQU_DEL_FLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-QMNUM sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-QMART sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-QMDAT sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-AUSVN sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-SWERK sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-IWERK sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-GEWRK sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-INGRP sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-REVNR sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-SYS_STATUS_TAB sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-USR_STATUS_SCHEMA sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-USR_STATUS_TAB sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-TPLNR sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-TPL_DEL_FLG sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-EQUNR sy-vline
WA_/ISDFPS/S_BRF_FOX_PM_NOTIF_STR-EQU_DEL_FLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.