ABAP Select data from SAP table /MDG/_S_0G_PDF_FSIKK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MDG/_S_0G_PDF_FSIKK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MDG/_S_0G_PDF_FSIKK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /MDG/_S_0G_PDF_FSIKK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/MDG/_S_0G_PDF_FSIKK TYPE STANDARD TABLE OF /MDG/_S_0G_PDF_FSIKK,
      WA_/MDG/_S_0G_PDF_FSIKK TYPE /MDG/_S_0G_PDF_FSIKK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </MDG/_S_0G_PDF_FSIKK> TYPE /MDG/_S_0G_PDF_FSIKK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/MDG/_S_0G_PDF_FSIKK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /MDG/_S_0G_PDF_FSIKK
  INTO TABLE IT_/MDG/_S_0G_PDF_FSIKK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /MDG/_S_0G_PDF_FSIKK
*  INTO TABLE @DATA(IT_/MDG/_S_0G_PDF_FSIKK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/MDG/_S_0G_PDF_FSIKK INDEX 1 INTO DATA(WA_/MDG/_S_0G_PDF_FSIKK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/MDG/_S_0G_PDF_FSIKK ASSIGNING </MDG/_S_0G_PDF_FSIKK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</MDG/_S_0G_PDF_FSIKK>-USMD_EDITION = 1.
</MDG/_S_0G_PDF_FSIKK>-COA = 1.
</MDG/_S_0G_PDF_FSIKK>-FSI = 1.
</MDG/_S_0G_PDF_FSIKK>-ACCGRPFSI = 1.
</MDG/_S_0G_PDF_FSIKK>-BDCFSI = 1.
ENDLOOP.

LOOP AT IT_/MDG/_S_0G_PDF_FSIKK INTO WA_/MDG/_S_0G_PDF_FSIKK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/MDG/_S_0G_PDF_FSIKK-CATEGFSI, sy-vline,
WA_/MDG/_S_0G_PDF_FSIKK-CNTXTFSI, sy-vline,
WA_/MDG/_S_0G_PDF_FSIKK-CURTYPFSI, sy-vline,
WA_/MDG/_S_0G_PDF_FSIKK-DIMFSI, sy-vline,
WA_/MDG/_S_0G_PDF_FSIKK-FSIBSIGN, sy-vline,
WA_/MDG/_S_0G_PDF_FSIKK-FSICNVID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/MDG/_S_0G_PDF_FSIKK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MDG/_S_0G_PDF_FSIKK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MDG/_S_0G_PDF_FSIKK INTO WA_/MDG/_S_0G_PDF_FSIKK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field USMD_EDITION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-USMD_EDITION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-USMD_EDITION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-FSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-FSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FSIELCFSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-FSIELCFSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-FSIELCFSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FSINEWFSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-FSINEWFSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-FSINEWFSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUBMPFSI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-SUBMPFSI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-SUBMPFSI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field USMD_ENT_CHNG_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-USMD_ENT_CHNG_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-USMD_ENT_CHNG_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field USMD_ENT_CRTD_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/MDG/_S_0G_PDF_FSIKK-USMD_ENT_CRTD_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_S_0G_PDF_FSIKK-USMD_ENT_CRTD_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MDG/_S_0G_PDF_FSIKK_STR,
USMD_EDITION TYPE STRING,
COA TYPE STRING,
FSI TYPE STRING,
ACCGRPFSI TYPE STRING,
BDCFSI TYPE STRING,
CATEGFSI TYPE STRING,
CNTXTFSI TYPE STRING,
CURTYPFSI TYPE STRING,
DIMFSI TYPE STRING,
FSIBSIGN TYPE STRING,
FSICNVID TYPE STRING,
FSICSCAL TYPE STRING,
FSIDECIM TYPE STRING,
FSIDESCR TYPE STRING,
FSIELCFSI TYPE STRING,
FSIFBLCRE TYPE STRING,
FSIFBLPLA TYPE STRING,
FSIFBLPOS TYPE STRING,
FSIFDEL TYPE STRING,
FSIFTYP TYPE STRING,
FSINEWFSI TYPE STRING,
FSIRESPP TYPE STRING,
FSIRESPU TYPE STRING,
FSISTAT TYPE STRING,
FSIUSAGE TYPE STRING,
MVMTFSI TYPE STRING,
SUBCFSI TYPE STRING,
SUBMPFSI TYPE STRING,
USMD_ENT_CHNG_AT TYPE STRING,
USMD_ENT_CHNG_BY TYPE STRING,
USMD_ENT_CRTD_AT TYPE STRING,
USMD_ENT_CRTD_BY TYPE STRING,
TXTLG TYPE STRING,
TXTMI TYPE STRING,
TXTSH TYPE STRING,
USMD_DESCRIPTION TYPE STRING,
USMD_EDITION TYPE STRING,
COA TYPE STRING,
FSI TYPE STRING,
BDCFSI TYPE STRING,
CATEGFSI TYPE STRING,
CNTXTFSI TYPE STRING,
CURTYPFSI TYPE STRING,
DIMFSI TYPE STRING,
FSIBSIGN TYPE STRING,
FSICNVID TYPE STRING,
FSICSCAL TYPE STRING,
FSIELCFSI TYPE STRING,
FSIFBLCRE TYPE STRING,
FSIFBLPLA TYPE STRING,
FSIFBLPOS TYPE STRING,
FSIFDEL TYPE STRING,
FSIFTYP TYPE STRING,
FSINEWFSI TYPE STRING,
FSIRESPU TYPE STRING,
FSISTAT TYPE STRING,
FSIUSAGE TYPE STRING,
MVMTFSI TYPE STRING,
SUBCFSI TYPE STRING,
SUBMPFSI TYPE STRING,
USMD_ENT_CHNG_BY TYPE STRING,
USMD_ENT_CRTD_BY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MDG/_S_0G_PDF_FSIKK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_EDITION sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-COA sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-ACCGRPFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-BDCFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-CATEGFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-CNTXTFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-CURTYPFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-DIMFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIBSIGN sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSICNVID sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSICSCAL sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIDECIM sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIDESCR sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIELCFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFBLCRE sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFBLPLA sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFBLPOS sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFDEL sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFTYP sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSINEWFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIRESPP sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIRESPU sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSISTAT sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIUSAGE sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-MVMTFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-SUBCFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-SUBMPFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_ENT_CHNG_AT sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_ENT_CHNG_BY sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_ENT_CRTD_AT sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_ENT_CRTD_BY sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-TXTLG sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-TXTMI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-TXTSH sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_DESCRIPTION sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_EDITION sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-COA sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-BDCFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-CATEGFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-CNTXTFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-CURTYPFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-DIMFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIBSIGN sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSICNVID sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSICSCAL sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIELCFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFBLCRE sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFBLPLA sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFBLPOS sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFDEL sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIFTYP sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSINEWFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIRESPU sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSISTAT sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-FSIUSAGE sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-MVMTFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-SUBCFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-SUBMPFSI sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_ENT_CHNG_BY sy-vline
WA_/MDG/_S_0G_PDF_FSIKK_STR-USMD_ENT_CRTD_BY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.