ABAP Select data from SAP table /MDG/_SX_0G_PDF_CONSUNIT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MDG/_SX_0G_PDF_CONSUNIT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MDG/_SX_0G_PDF_CONSUNIT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /MDG/_SX_0G_PDF_CONSUNIT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/MDG/_SX_0G_PDF_CONSUNIT TYPE STANDARD TABLE OF /MDG/_SX_0G_PDF_CONSUNIT,
      WA_/MDG/_SX_0G_PDF_CONSUNIT TYPE /MDG/_SX_0G_PDF_CONSUNIT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </MDG/_SX_0G_PDF_CONSUNIT> TYPE /MDG/_SX_0G_PDF_CONSUNIT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/MDG/_SX_0G_PDF_CONSUNIT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /MDG/_SX_0G_PDF_CONSUNIT
  INTO TABLE IT_/MDG/_SX_0G_PDF_CONSUNIT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /MDG/_SX_0G_PDF_CONSUNIT
*  INTO TABLE @DATA(IT_/MDG/_SX_0G_PDF_CONSUNIT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/MDG/_SX_0G_PDF_CONSUNIT INDEX 1 INTO DATA(WA_/MDG/_SX_0G_PDF_CONSUNIT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/MDG/_SX_0G_PDF_CONSUNIT ASSIGNING </MDG/_SX_0G_PDF_CONSUNIT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</MDG/_SX_0G_PDF_CONSUNIT>-USMD_EDITION = 1.
</MDG/_SX_0G_PDF_CONSUNIT>-USMD_VDATE_FROM = 1.
</MDG/_SX_0G_PDF_CONSUNIT>-USMD_VDATE_TO = 1.
</MDG/_SX_0G_PDF_CONSUNIT>-USMD_VPER_FROM = 1.
</MDG/_SX_0G_PDF_CONSUNIT>-USMD_VPER_TO = 1.
ENDLOOP.

LOOP AT IT_/MDG/_SX_0G_PDF_CONSUNIT INTO WA_/MDG/_SX_0G_PDF_CONSUNIT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_EDITION_TO, sy-vline,
WA_/MDG/_SX_0G_PDF_CONSUNIT-CONSCHAR, sy-vline,
WA_/MDG/_SX_0G_PDF_CONSUNIT-CONSUNIT, sy-vline,
WA_/MDG/_SX_0G_PDF_CONSUNIT-CACU, sy-vline,
WA_/MDG/_SX_0G_PDF_CONSUNIT-CCCU, sy-vline,
WA_/MDG/_SX_0G_PDF_CONSUNIT-COMPCU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/MDG/_SX_0G_PDF_CONSUNIT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MDG/_SX_0G_PDF_CONSUNIT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MDG/_SX_0G_PDF_CONSUNIT INTO WA_/MDG/_SX_0G_PDF_CONSUNIT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field USMD_EDITION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_EDITION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_EDITION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field USMD_VPER_FROM CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_VPER_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_VPER_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field USMD_VPER_TO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_VPER_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_VPER_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field USMD_EDITION_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_EDITION_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_EDITION_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONSUNIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-CONSUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-CONSUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COMPCU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-COMPCU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-COMPCU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CU1STDEY CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-CU1STDEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-CU1STDEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PCTRCU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-PCTRCU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-PCTRCU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field USMD_ENT_CHNG_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_ENT_CHNG_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_ENT_CHNG_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field USMD_ENT_CRTD_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_ENT_CRTD_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MDG/_SX_0G_PDF_CONSUNIT-USMD_ENT_CRTD_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MDG/_SX_0G_PDF_CONSUNIT_STR,
USMD_EDITION TYPE STRING,
USMD_VDATE_FROM TYPE STRING,
USMD_VDATE_TO TYPE STRING,
USMD_VPER_FROM TYPE STRING,
USMD_VPER_TO TYPE STRING,
USMD_EDITION_TO TYPE STRING,
CONSCHAR TYPE STRING,
CONSUNIT TYPE STRING,
CACU TYPE STRING,
CCCU TYPE STRING,
COMPCU TYPE STRING,
CU1STDEP TYPE STRING,
CU1STDEY TYPE STRING,
CUDESC1 TYPE STRING,
CUDESC2 TYPE STRING,
CUFISCYV TYPE STRING,
CURRCU TYPE STRING,
CUTAXRATE TYPE STRING,
CUTCU TYPE STRING,
DIVCU TYPE STRING,
ICCONU TYPE STRING,
ICCONUFLG TYPE STRING,
MUCU TYPE STRING,
PCTRCU TYPE STRING,
SCALFACTR TYPE STRING,
TXTLG TYPE STRING,
TXTMI TYPE STRING,
TXTSH TYPE STRING,
USMD_ENT_CHNG_AT TYPE STRING,
USMD_ENT_CHNG_BY TYPE STRING,
USMD_ENT_CRTD_AT TYPE STRING,
USMD_ENT_CRTD_BY TYPE STRING,
USMD_DESCRIPTION TYPE STRING,
USMD_EDITION TYPE STRING,
CONSCHAR TYPE STRING,
CONSUNIT TYPE STRING,
CACU TYPE STRING,
CCCU TYPE STRING,
COMPCU TYPE STRING,
CUFISCYV TYPE STRING,
CURRCU TYPE STRING,
CUTCU TYPE STRING,
DIVCU TYPE STRING,
ICCONUFLG TYPE STRING,
MUCU TYPE STRING,
PCTRCU TYPE STRING,
USMD_ENT_CHNG_BY TYPE STRING,
USMD_ENT_CRTD_BY TYPE STRING,
USMD_EDITION_TO TYPE STRING,
CONSSCOPE TYPE STRING,
HRY_ACCOUNTING TYPE STRING,
HRY_ASSIGNMENT TYPE STRING,
USMD_T_CUVERS TYPE STRING,
USMD_T_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MDG/_SX_0G_PDF_CONSUNIT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_EDITION sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_VDATE_FROM sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_VDATE_TO sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_VPER_FROM sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_VPER_TO sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_EDITION_TO sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CONSCHAR sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CONSUNIT sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CACU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CCCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-COMPCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CU1STDEP sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CU1STDEY sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUDESC1 sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUDESC2 sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUFISCYV sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CURRCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUTAXRATE sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUTCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-DIVCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-ICCONU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-ICCONUFLG sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-MUCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-PCTRCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-SCALFACTR sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-TXTLG sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-TXTMI sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-TXTSH sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_ENT_CHNG_AT sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_ENT_CHNG_BY sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_ENT_CRTD_AT sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_ENT_CRTD_BY sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_DESCRIPTION sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_EDITION sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CONSCHAR sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CONSUNIT sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CACU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CCCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-COMPCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUFISCYV sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CURRCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CUTCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-DIVCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-ICCONUFLG sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-MUCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-PCTRCU sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_ENT_CHNG_BY sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_ENT_CRTD_BY sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_EDITION_TO sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-CONSSCOPE sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-HRY_ACCOUNTING sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-HRY_ASSIGNMENT sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_T_CUVERS sy-vline
WA_/MDG/_SX_0G_PDF_CONSUNIT_STR-USMD_T_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.