ABAP Select data from SAP table /MVA/AMDCBMOWNER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MVA/AMDCBMOWNER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MVA/AMDCBMOWNER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /MVA/AMDCBMOWNER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/MVA/AMDCBMOWNER TYPE STANDARD TABLE OF /MVA/AMDCBMOWNER,
      WA_/MVA/AMDCBMOWNER TYPE /MVA/AMDCBMOWNER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </MVA/AMDCBMOWNER> TYPE /MVA/AMDCBMOWNER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/MVA/AMDCBMOWNER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /MVA/AMDCBMOWNER
  INTO TABLE IT_/MVA/AMDCBMOWNER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /MVA/AMDCBMOWNER
*  INTO TABLE @DATA(IT_/MVA/AMDCBMOWNER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/MVA/AMDCBMOWNER INDEX 1 INTO DATA(WA_/MVA/AMDCBMOWNER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/MVA/AMDCBMOWNER ASSIGNING </MVA/AMDCBMOWNER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</MVA/AMDCBMOWNER>-CLIENT = 1.
</MVA/AMDCBMOWNER>-DCC_GUID = 1.
</MVA/AMDCBMOWNER>-DC_GUID = 1.
</MVA/AMDCBMOWNER>-BO_ID = 1.
</MVA/AMDCBMOWNER>-POLICY_ID = 1.
ENDLOOP.

LOOP AT IT_/MVA/AMDCBMOWNER INTO WA_/MVA/AMDCBMOWNER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/MVA/AMDCBMOWNER-PPDPAC_ID, sy-vline,
WA_/MVA/AMDCBMOWNER-POLICYPRODUCT_ID, sy-vline,
WA_/MVA/AMDCBMOWNER-COVPAC_ID, sy-vline,
WA_/MVA/AMDCBMOWNER-COVERAGE_ID, sy-vline,
WA_/MVA/AMDCBMOWNER-/MVA/BM_ID, sy-vline,
WA_/MVA/AMDCBMOWNER-/MVA/BMOWNER_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/MVA/AMDCBMOWNER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MVA/AMDCBMOWNER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MVA/AMDCBMOWNER INTO WA_/MVA/AMDCBMOWNER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit J7ADR, internal->external for field ADDRESSNUMBER_ID CALL FUNCTION 'CONVERSION_EXIT_J7ADR_OUTPUT' EXPORTING input = WA_/MVA/AMDCBMOWNER-ADDRESSNUMBER_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MVA/AMDCBMOWNER-ADDRESSNUMBER_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/MVA/AMDCBMOWNER-PARTNER_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/MVA/AMDCBMOWNER-PARTNER_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MVA/AMDCBMOWNER_STR,
CLIENT TYPE STRING,
DCC_GUID TYPE STRING,
DC_GUID TYPE STRING,
BO_ID TYPE STRING,
POLICY_ID TYPE STRING,
PPDPAC_ID TYPE STRING,
POLICYPRODUCT_ID TYPE STRING,
COVPAC_ID TYPE STRING,
COVERAGE_ID TYPE STRING,
/MVA/BM_ID TYPE STRING,
/MVA/BMOWNER_ID TYPE STRING,
UPD_CD TYPE STRING,
ADDRESSNUMBER_ID TYPE STRING,
PARTNER_ID TYPE STRING,
PM_ID TYPE STRING,
CUSTOMER_PM_CI TYPE STRING,
AMDABMOWNE_OID_X TYPE STRING,
CANCEL_FG_X TYPE STRING,
ADDRESSNUMB_ID_X TYPE STRING,
PARTNER_ID_X TYPE STRING,
PM_ID_X TYPE STRING,
CUSTOMER_PM_CI_X TYPE STRING,
PARTNERNAME_TT_X TYPE STRING,
CUSTOMER_TM_CI_X TYPE STRING,
POL_TMPL_ID TYPE STRING,
POLPRPAC_TMPL_ID TYPE STRING,
POLPR_TMPL_ID TYPE STRING,
COVPAC_TMPL_ID TYPE STRING,
COV_TMPL_ID TYPE STRING,
COVCPCO_TMPL_ID TYPE STRING,
SUBJCTPM_TMPL_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MVA/AMDCBMOWNER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MVA/AMDCBMOWNER_STR-CLIENT sy-vline
WA_/MVA/AMDCBMOWNER_STR-DCC_GUID sy-vline
WA_/MVA/AMDCBMOWNER_STR-DC_GUID sy-vline
WA_/MVA/AMDCBMOWNER_STR-BO_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-POLICY_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-PPDPAC_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-POLICYPRODUCT_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-COVPAC_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-COVERAGE_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-/MVA/BM_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-/MVA/BMOWNER_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-UPD_CD sy-vline
WA_/MVA/AMDCBMOWNER_STR-ADDRESSNUMBER_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-PARTNER_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-PM_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-CUSTOMER_PM_CI sy-vline
WA_/MVA/AMDCBMOWNER_STR-AMDABMOWNE_OID_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-CANCEL_FG_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-ADDRESSNUMB_ID_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-PARTNER_ID_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-PM_ID_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-CUSTOMER_PM_CI_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-PARTNERNAME_TT_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-CUSTOMER_TM_CI_X sy-vline
WA_/MVA/AMDCBMOWNER_STR-POL_TMPL_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-POLPRPAC_TMPL_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-POLPR_TMPL_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-COVPAC_TMPL_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-COV_TMPL_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-COVCPCO_TMPL_ID sy-vline
WA_/MVA/AMDCBMOWNER_STR-SUBJCTPM_TMPL_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.