ABAP Select data from SAP table /MVA/E1BP_AMQRSAAPPEND into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /MVA/E1BP_AMQRSAAPPEND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /MVA/E1BP_AMQRSAAPPEND. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /MVA/E1BP_AMQRSAAPPEND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/MVA/E1BP_AMQRSAAPPEND TYPE STANDARD TABLE OF /MVA/E1BP_AMQRSAAPPEND, WA_/MVA/E1BP_AMQRSAAPPEND TYPE /MVA/E1BP_AMQRSAAPPEND, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </MVA/E1BP_AMQRSAAPPEND> TYPE /MVA/E1BP_AMQRSAAPPEND. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/MVA/E1BP_AMQRSAAPPEND. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /MVA/E1BP_AMQRSAAPPEND INTO TABLE IT_/MVA/E1BP_AMQRSAAPPEND. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /MVA/E1BP_AMQRSAAPPEND * INTO TABLE @DATA(IT_/MVA/E1BP_AMQRSAAPPEND2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/MVA/E1BP_AMQRSAAPPEND INDEX 1 INTO DATA(WA_/MVA/E1BP_AMQRSAAPPEND2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/MVA/E1BP_AMQRSAAPPEND ASSIGNING </MVA/E1BP_AMQRSAAPPEND>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</MVA/E1BP_AMQRSAAPPEND>-MIG_MSG_ID = 1.
</MVA/E1BP_AMQRSAAPPEND>-/MVA/SEQUNR_ID = 1.
</MVA/E1BP_AMQRSAAPPEND>-/MVA/SEGMENT_CD = 1.
</MVA/E1BP_AMQRSAAPPEND>-/MVA/USEDEST1_CD = 1.
</MVA/E1BP_AMQRSAAPPEND>-/MVA/USEDEST2_CD = 1.
ENDLOOP. LOOP AT IT_/MVA/E1BP_AMQRSAAPPEND INTO WA_/MVA/E1BP_AMQRSAAPPEND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/MVA/E1BP_AMQRSAAPPEND-/MVA/APPL_INS_CD, sy-vline,
WA_/MVA/E1BP_AMQRSAAPPEND-/MVA/NEW_USED_CD, sy-vline,
WA_/MVA/E1BP_AMQRSAAPPEND-/MVA/IMP_LIC_CD, sy-vline,
WA_/MVA/E1BP_AMQRSAAPPEND-/MVA/NONCOMPU_FG, sy-vline,
WA_/MVA/E1BP_AMQRSAAPPEND-/MVA/LICBASIC_CD, sy-vline,
WA_/MVA/E1BP_AMQRSAAPPEND-/MVA/ASSENTNR_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/MVA/E1BP_AMQRSAAPPEND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/MVA/E1BP_AMQRSAAPPEND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/MVA/E1BP_AMQRSAAPPEND INTO WA_/MVA/E1BP_AMQRSAAPPEND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/MVA/E1BP_AMQRSAAPPEND_STR,
MIG_MSG_ID TYPE STRING,
/MVA/SEQUNR_ID TYPE STRING,
/MVA/SEGMENT_CD TYPE STRING,
/MVA/USEDEST1_CD TYPE STRING,
/MVA/USEDEST2_CD TYPE STRING,
/MVA/APPL_INS_CD TYPE STRING,
/MVA/NEW_USED_CD TYPE STRING,
/MVA/IMP_LIC_CD TYPE STRING,
/MVA/NONCOMPU_FG TYPE STRING,
/MVA/LICBASIC_CD TYPE STRING,
/MVA/ASSENTNR_CD TYPE STRING,
/MVA/TESTNR_CD TYPE STRING,
/MVA/ASSENT_DT TYPE STRING,
/MVA/NAT_CD TYPE STRING,
/MVA/CONST_TT TYPE STRING,
/MVA/VEHDRIVE_CD TYPE STRING,
/MVA/SEATS_CD TYPE STRING,
/MVA/TARE_CD TYPE STRING,
/MVA/PAYLOAD_CD TYPE STRING,
/MVA/DISP_CD TYPE STRING,
/MVA/POWER_CD TYPE STRING,
/MVA/SPEED_CD TYPE STRING,
/MVA/NOISELEV_CD TYPE STRING,
/MVA/BL_RAGE_CD TYPE STRING,
/MVA/TL_NONBR_CD TYPE STRING,
/MVA/TL_BR_CD TYPE STRING,
/MVA/VERTCOUP_CD TYPE STRING,
/MVA/NUM_FOOT_CD TYPE STRING,
/MVA/HIGHWHEL_CD TYPE STRING,
/MVA/HUBLOAD1_CD TYPE STRING,
/MVA/HUBLOAD2_CD TYPE STRING,
/MVA/HUBLOAD3_CD TYPE STRING,
/MVA/HUBLOAD4_CD TYPE STRING,
/MVA/CROSSCOU_CD TYPE STRING,
/MVA/SPECEQU1_CD TYPE STRING,
/MVA/SPECEQU2_CD TYPE STRING,
/MVA/FUELCONO_CD TYPE STRING,
/MVA/FUELCON_CD TYPE STRING,
/MVA/CO2_CD TYPE STRING,
/MVA/CONST_CD TYPE STRING,
/MVA/EXHEMISC_CD TYPE STRING,
/MVA/CONSUM_UT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/MVA/E1BP_AMQRSAAPPEND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-MIG_MSG_ID sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/SEQUNR_ID sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/SEGMENT_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/USEDEST1_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/USEDEST2_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/APPL_INS_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/NEW_USED_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/IMP_LIC_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/NONCOMPU_FG sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/LICBASIC_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/ASSENTNR_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/TESTNR_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/ASSENT_DT sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/NAT_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/CONST_TT sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/VEHDRIVE_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/SEATS_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/TARE_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/PAYLOAD_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/DISP_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/POWER_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/SPEED_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/NOISELEV_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/BL_RAGE_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/TL_NONBR_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/TL_BR_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/VERTCOUP_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/NUM_FOOT_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/HIGHWHEL_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/HUBLOAD1_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/HUBLOAD2_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/HUBLOAD3_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/HUBLOAD4_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/CROSSCOU_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/SPECEQU1_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/SPECEQU2_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/FUELCONO_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/FUELCON_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/CO2_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/CONST_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/EXHEMISC_CD sy-vline
WA_/MVA/E1BP_AMQRSAAPPEND_STR-/MVA/CONSUM_UT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.