ABAP Select data from SAP table /PLMB/S_MAT_BASIC_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMB/S_MAT_BASIC_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMB/S_MAT_BASIC_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMB/S_MAT_BASIC_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMB/S_MAT_BASIC_DATA TYPE STANDARD TABLE OF /PLMB/S_MAT_BASIC_DATA,
      WA_/PLMB/S_MAT_BASIC_DATA TYPE /PLMB/S_MAT_BASIC_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMB/S_MAT_BASIC_DATA> TYPE /PLMB/S_MAT_BASIC_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMB/S_MAT_BASIC_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMB/S_MAT_BASIC_DATA
  INTO TABLE IT_/PLMB/S_MAT_BASIC_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMB/S_MAT_BASIC_DATA
*  INTO TABLE @DATA(IT_/PLMB/S_MAT_BASIC_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMB/S_MAT_BASIC_DATA INDEX 1 INTO DATA(WA_/PLMB/S_MAT_BASIC_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMB/S_MAT_BASIC_DATA ASSIGNING </PLMB/S_MAT_BASIC_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMB/S_MAT_BASIC_DATA>-MBRSH = 1.
</PLMB/S_MAT_BASIC_DATA>-MTART = 1.
</PLMB/S_MAT_BASIC_DATA>-AENNR = 1.
</PLMB/S_MAT_BASIC_DATA>-MEINS = 1.
</PLMB/S_MAT_BASIC_DATA>-CADKZ = 1.
ENDLOOP.

LOOP AT IT_/PLMB/S_MAT_BASIC_DATA INTO WA_/PLMB/S_MAT_BASIC_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMB/S_MAT_BASIC_DATA-MATKL, sy-vline,
WA_/PLMB/S_MAT_BASIC_DATA-EXTWG, sy-vline,
WA_/PLMB/S_MAT_BASIC_DATA-SPART, sy-vline,
WA_/PLMB/S_MAT_BASIC_DATA-LABOR, sy-vline,
WA_/PLMB/S_MAT_BASIC_DATA-PRODH_D, sy-vline,
WA_/PLMB/S_MAT_BASIC_DATA-NORMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMB/S_MAT_BASIC_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMB/S_MAT_BASIC_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMB/S_MAT_BASIC_DATA INTO WA_/PLMB/S_MAT_BASIC_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEABM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-MEABM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-MEABM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN3, internal->external for field STOFF CALL FUNCTION 'CONVERSION_EXIT_MATN3_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-STOFF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-STOFF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MFRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-MFRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-MFRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field COPY_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_MAT_BASIC_DATA-COPY_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_MAT_BASIC_DATA-COPY_MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMB/S_MAT_BASIC_DATA_STR,
MBRSH TYPE STRING,
MTART TYPE STRING,
AENNR TYPE STRING,
MEINS TYPE STRING,
CADKZ TYPE STRING,
MATKL TYPE STRING,
EXTWG TYPE STRING,
SPART TYPE STRING,
LABOR TYPE STRING,
PRODH_D TYPE STRING,
NORMT TYPE STRING,
BISMT TYPE STRING,
WRKST TYPE STRING,
EAN11 TYPE STRING,
NUMTP TYPE STRING,
MSTAE TYPE STRING,
MSTDE TYPE STRING,
MSTAV TYPE STRING,
MSTDV TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
NTGEW TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
LAENG TYPE STRING,
MEABM TYPE STRING,
BREIT TYPE STRING,
HOEHE TYPE STRING,
GROES TYPE STRING,
STOFF TYPE STRING,
KZUMW TYPE STRING,
KZKFG TYPE STRING,
MFRPN TYPE STRING,
MFRNR TYPE STRING,
MPROF TYPE STRING,
ERSDA TYPE STRING,
ERNAM TYPE STRING,
LAEDA TYPE STRING,
AENAM TYPE STRING,
COPY_MATERIAL TYPE STRING,
MODE_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMB/S_MAT_BASIC_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MBRSH sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MTART sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-AENNR sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MEINS sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-CADKZ sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MATKL sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-EXTWG sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-SPART sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-LABOR sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-PRODH_D sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-NORMT sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-BISMT sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-WRKST sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-EAN11 sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-NUMTP sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MSTAE sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MSTDE sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MSTAV sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MSTDV sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-BRGEW sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-GEWEI sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-NTGEW sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-VOLUM sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-VOLEH sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-LAENG sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MEABM sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-BREIT sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-HOEHE sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-GROES sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-STOFF sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-KZUMW sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-KZKFG sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MFRPN sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MFRNR sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MPROF sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-ERSDA sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-ERNAM sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-LAEDA sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-AENAM sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-COPY_MATERIAL sy-vline
WA_/PLMB/S_MAT_BASIC_DATA_STR-MODE_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.