ABAP Select data from SAP table /PLMB/S_RTG_PRT_INS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMB/S_RTG_PRT_INS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMB/S_RTG_PRT_INS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PLMB/S_RTG_PRT_INS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PLMB/S_RTG_PRT_INS TYPE STANDARD TABLE OF /PLMB/S_RTG_PRT_INS,
      WA_/PLMB/S_RTG_PRT_INS TYPE /PLMB/S_RTG_PRT_INS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PLMB/S_RTG_PRT_INS> TYPE /PLMB/S_RTG_PRT_INS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PLMB/S_RTG_PRT_INS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PLMB/S_RTG_PRT_INS
  INTO TABLE IT_/PLMB/S_RTG_PRT_INS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PLMB/S_RTG_PRT_INS
*  INTO TABLE @DATA(IT_/PLMB/S_RTG_PRT_INS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PLMB/S_RTG_PRT_INS INDEX 1 INTO DATA(WA_/PLMB/S_RTG_PRT_INS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PLMB/S_RTG_PRT_INS ASSIGNING </PLMB/S_RTG_PRT_INS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMB/S_RTG_PRT_INS>-PLNTY = 1.
</PLMB/S_RTG_PRT_INS>-PLNNR = 1.
</PLMB/S_RTG_PRT_INS>-PLNAL = 1.
</PLMB/S_RTG_PRT_INS>-PLNFL = 1.
</PLMB/S_RTG_PRT_INS>-PLNKN = 1.
ENDLOOP.

LOOP AT IT_/PLMB/S_RTG_PRT_INS INTO WA_/PLMB/S_RTG_PRT_INS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PLMB/S_RTG_PRT_INS-TECHV, sy-vline,
WA_/PLMB/S_RTG_PRT_INS-OBJTY, sy-vline,
WA_/PLMB/S_RTG_PRT_INS-OBJID, sy-vline,
WA_/PLMB/S_RTG_PRT_INS-OBJCT, sy-vline,
WA_/PLMB/S_RTG_PRT_INS-PSNFH, sy-vline,
WA_/PLMB/S_RTG_PRT_INS-STEUF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMB/S_RTG_PRT_INS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMB/S_RTG_PRT_INS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMB/S_RTG_PRT_INS INTO WA_/PLMB/S_RTG_PRT_INS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-EHOFFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-EHOFFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-EHOFFE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-EHOFFE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MGEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-MGEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-MGEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EWEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-EWEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-EWEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VPLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-VPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-VPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VPLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-VPLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-VPLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FHMAR, internal->external for field FHMAR CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-FHMAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-FHMAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SFHNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-SFHNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-SFHNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-DOKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQWPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-EQWPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-EQWPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQPNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-EQPNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-EQPNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-MSEHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-BASEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-BASEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR_AUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-AENNR_AUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-AENNR_AUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMB/S_RTG_PRT_INS-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMB/S_RTG_PRT_INS-VORNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMB/S_RTG_PRT_INS_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PLNFL TYPE STRING,
PLNKN TYPE STRING,
TECHV TYPE STRING,
OBJTY TYPE STRING,
OBJID TYPE STRING,
OBJCT TYPE STRING,
PSNFH TYPE STRING,
STEUF TYPE STRING,
KZKBL TYPE STRING,
BZOFFB TYPE STRING,
OFFSTB TYPE STRING,
EHOFFB TYPE STRING,
BZOFFE TYPE STRING,
OFFSTE TYPE STRING,
EHOFFE TYPE STRING,
MGEINH TYPE STRING,
MGVGW TYPE STRING,
MGFORM TYPE STRING,
EWEINH TYPE STRING,
EWVGW TYPE STRING,
EWFORM TYPE STRING,
TXTSP TYPE STRING,
KTSCH TYPE STRING,
TXTZ1 TYPE STRING,
KNOBJ TYPE STRING,
GP_KRIT1 TYPE STRING,
VPLTY TYPE STRING,
VPLNR TYPE STRING,
VPLAL TYPE STRING,
IDENT TYPE STRING,
IDENT_REF TYPE STRING,
HERKUNFT TYPE STRING,
MGSOL TYPE STRING,
MGIST TYPE STRING,
MGRST TYPE STRING,
MGAUS TYPE STRING,
EWSOL TYPE STRING,
EWIST TYPE STRING,
EWRST TYPE STRING,
FHMAR TYPE STRING,
FHMNR TYPE STRING,
FHWRK TYPE STRING,
MATNR TYPE STRING,
SFHNR TYPE STRING,
DOKAR TYPE STRING,
DOKNR TYPE STRING,
DOKTL TYPE STRING,
DOKVR TYPE STRING,
EQUNR TYPE STRING,
EQWPL TYPE STRING,
EQWTX TYPE STRING,
EQPNT TYPE STRING,
EQPTX TYPE STRING,
ATNAM TYPE STRING,
ATVOR TYPE STRING,
MSEHI TYPE STRING,
ATDIM TYPE STRING,
ANZDZ TYPE STRING,
FHKTX TYPE STRING,
BASEH TYPE STRING,
MEINS TYPE STRING,
FGRU1 TYPE STRING,
FGRU2 TYPE STRING,
STOWK TYPE STRING,
STORT TYPE STRING,
STEUF_REF TYPE STRING,
KTSCH_REF TYPE STRING,
BZOFFB_REF TYPE STRING,
OFFSTB_REF TYPE STRING,
BZOFFE_REF TYPE STRING,
OFFSTE_REF TYPE STRING,
MGFORM_REF TYPE STRING,
EWFORM_REF TYPE STRING,
DATUB TYPE STRING,
AENNR_AUS TYPE STRING,
TXTKZ TYPE STRING,
CF_KZSVS TYPE STRING,
CF_KZSVE TYPE STRING,
CF_KZEVS TYPE STRING,
CF_KZEVE TYPE STRING,
VORNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMB/S_RTG_PRT_INS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-PLNTY sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-PLNNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-PLNAL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-PLNFL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-PLNKN sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-TECHV sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OBJTY sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OBJID sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OBJCT sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-PSNFH sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-STEUF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-KZKBL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-BZOFFB sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OFFSTB sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EHOFFB sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-BZOFFE sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OFFSTE sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EHOFFE sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGEINH sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGVGW sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGFORM sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWEINH sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWVGW sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWFORM sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-TXTSP sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-KTSCH sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-TXTZ1 sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-KNOBJ sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-GP_KRIT1 sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-VPLTY sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-VPLNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-VPLAL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-IDENT sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-IDENT_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-HERKUNFT sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGSOL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGIST sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGRST sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGAUS sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWSOL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWIST sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWRST sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-FHMAR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-FHMNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-FHWRK sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MATNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-SFHNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-DOKAR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-DOKNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-DOKTL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-DOKVR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EQUNR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EQWPL sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EQWTX sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EQPNT sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EQPTX sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-ATNAM sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-ATVOR sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MSEHI sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-ATDIM sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-ANZDZ sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-FHKTX sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-BASEH sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MEINS sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-FGRU1 sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-FGRU2 sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-STOWK sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-STORT sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-STEUF_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-KTSCH_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-BZOFFB_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OFFSTB_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-BZOFFE_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-OFFSTE_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-MGFORM_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-EWFORM_REF sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-DATUB sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-AENNR_AUS sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-TXTKZ sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-CF_KZSVS sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-CF_KZSVE sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-CF_KZEVS sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-CF_KZEVE sy-vline
WA_/PLMB/S_RTG_PRT_INS_STR-VORNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.