ABAP Select data from SAP table /PLMI/S_NAV_MAT_ID_ATTR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMI/S_NAV_MAT_ID_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMI/S_NAV_MAT_ID_ATTR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PLMI/S_NAV_MAT_ID_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PLMI/S_NAV_MAT_ID_ATTR TYPE STANDARD TABLE OF /PLMI/S_NAV_MAT_ID_ATTR, WA_/PLMI/S_NAV_MAT_ID_ATTR TYPE /PLMI/S_NAV_MAT_ID_ATTR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PLMI/S_NAV_MAT_ID_ATTR> TYPE /PLMI/S_NAV_MAT_ID_ATTR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PLMI/S_NAV_MAT_ID_ATTR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PLMI/S_NAV_MAT_ID_ATTR INTO TABLE IT_/PLMI/S_NAV_MAT_ID_ATTR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PLMI/S_NAV_MAT_ID_ATTR * INTO TABLE @DATA(IT_/PLMI/S_NAV_MAT_ID_ATTR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PLMI/S_NAV_MAT_ID_ATTR INDEX 1 INTO DATA(WA_/PLMI/S_NAV_MAT_ID_ATTR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PLMI/S_NAV_MAT_ID_ATTR ASSIGNING </PLMI/S_NAV_MAT_ID_ATTR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMI/S_NAV_MAT_ID_ATTR>-INTID = 1.
</PLMI/S_NAV_MAT_ID_ATTR>-NAV_LOGSYS = 1.
</PLMI/S_NAV_MAT_ID_ATTR>-DISPLAY_KEY = 1.
</PLMI/S_NAV_MAT_ID_ATTR>-DESCRIPTION = 1.
</PLMI/S_NAV_MAT_ID_ATTR>-DEL_IND = 1.
ENDLOOP. LOOP AT IT_/PLMI/S_NAV_MAT_ID_ATTR INTO WA_/PLMI/S_NAV_MAT_ID_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PLMI/S_NAV_MAT_ID_ATTR-MTART, sy-vline,
WA_/PLMI/S_NAV_MAT_ID_ATTR-MTBEZ, sy-vline,
WA_/PLMI/S_NAV_MAT_ID_ATTR-MATKL, sy-vline,
WA_/PLMI/S_NAV_MAT_ID_ATTR-MEINS, sy-vline,
WA_/PLMI/S_NAV_MAT_ID_ATTR-LABOR, sy-vline,
WA_/PLMI/S_NAV_MAT_ID_ATTR-VCHNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMI/S_NAV_MAT_ID_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMI/S_NAV_MAT_ID_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMI/S_NAV_MAT_ID_ATTR INTO WA_/PLMI/S_NAV_MAT_ID_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field NAV_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMI/S_NAV_MAT_ID_ATTR-NAV_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_NAV_MAT_ID_ATTR-NAV_LOGSYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PLMI/S_NAV_MAT_ID_ATTR-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_NAV_MAT_ID_ATTR-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VCHNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMI/S_NAV_MAT_ID_ATTR-VCHNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_NAV_MAT_ID_ATTR-VCHNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field REVLEVEL CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_/PLMI/S_NAV_MAT_ID_ATTR-REVLEVEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_NAV_MAT_ID_ATTR-REVLEVEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMI/S_NAV_MAT_ID_ATTR_STR,
INTID TYPE STRING,
NAV_LOGSYS TYPE STRING,
DISPLAY_KEY TYPE STRING,
DESCRIPTION TYPE STRING,
DEL_IND TYPE STRING,
MTART TYPE STRING,
MTBEZ TYPE STRING,
MATKL TYPE STRING,
MEINS TYPE STRING,
LABOR TYPE STRING,
VCHNR TYPE STRING,
VALID_FROM_NAV TYPE STRING,
VALID_FROM_AENNR TYPE STRING,
PARAM_EFF TYPE STRING,
STATUS TYPE STRING,
STATUS_DESC TYPE STRING,
SCHEMA_ID TYPE STRING,
STATUS_ICON TYPE STRING,
CAD_IND TYPE STRING,
SPART_TEXT TYPE STRING,
REVLEVEL TYPE STRING,
ACC_ID_EXT TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
CHANGED_BY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMI/S_NAV_MAT_ID_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-INTID sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-NAV_LOGSYS sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-DISPLAY_KEY sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-DESCRIPTION sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-DEL_IND sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-MTART sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-MTBEZ sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-MATKL sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-MEINS sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-LABOR sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-VCHNR sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-VALID_FROM_NAV sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-VALID_FROM_AENNR sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-PARAM_EFF sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-STATUS sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-STATUS_DESC sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-SCHEMA_ID sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-STATUS_ICON sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-CAD_IND sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-SPART_TEXT sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-REVLEVEL sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-ACC_ID_EXT sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-CREATED_ON sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-CREATED_BY sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-CHANGED_ON sy-vline
WA_/PLMI/S_NAV_MAT_ID_ATTR_STR-CHANGED_BY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.