ABAP Select data from SAP table /PLMI/S_PPE_EXPL_VARIANT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMI/S_PPE_EXPL_VARIANT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMI/S_PPE_EXPL_VARIANT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PLMI/S_PPE_EXPL_VARIANT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PLMI/S_PPE_EXPL_VARIANT TYPE STANDARD TABLE OF /PLMI/S_PPE_EXPL_VARIANT, WA_/PLMI/S_PPE_EXPL_VARIANT TYPE /PLMI/S_PPE_EXPL_VARIANT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PLMI/S_PPE_EXPL_VARIANT> TYPE /PLMI/S_PPE_EXPL_VARIANT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PLMI/S_PPE_EXPL_VARIANT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PLMI/S_PPE_EXPL_VARIANT INTO TABLE IT_/PLMI/S_PPE_EXPL_VARIANT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PLMI/S_PPE_EXPL_VARIANT * INTO TABLE @DATA(IT_/PLMI/S_PPE_EXPL_VARIANT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PLMI/S_PPE_EXPL_VARIANT INDEX 1 INTO DATA(WA_/PLMI/S_PPE_EXPL_VARIANT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PLMI/S_PPE_EXPL_VARIANT ASSIGNING </PLMI/S_PPE_EXPL_VARIANT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMI/S_PPE_EXPL_VARIANT>-OBJECT_TYPE = 1.
</PLMI/S_PPE_EXPL_VARIANT>-GUID = 1.
</PLMI/S_PPE_EXPL_VARIANT>-ECN_COUNTER = 1.
</PLMI/S_PPE_EXPL_VARIANT>-VARIANT_TYPE = 1.
</PLMI/S_PPE_EXPL_VARIANT>-APPLOBJ_TYPE = 1.
ENDLOOP. LOOP AT IT_/PLMI/S_PPE_EXPL_VARIANT INTO WA_/PLMI/S_PPE_EXPL_VARIANT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PLMI/S_PPE_EXPL_VARIANT-NODE_GUID, sy-vline,
WA_/PLMI/S_PPE_EXPL_VARIANT-NAMEID, sy-vline,
WA_/PLMI/S_PPE_EXPL_VARIANT-CHANGE_NO, sy-vline,
WA_/PLMI/S_PPE_EXPL_VARIANT-DELETION_FLAG, sy-vline,
WA_/PLMI/S_PPE_EXPL_VARIANT-CMPID, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/PLMI/S_PPE_EXPL_VARIANT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMI/S_PPE_EXPL_VARIANT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMI/S_PPE_EXPL_VARIANT INTO WA_/PLMI/S_PPE_EXPL_VARIANT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field CHANGE_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMI/S_PPE_EXPL_VARIANT-CHANGE_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/S_PPE_EXPL_VARIANT-CHANGE_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMI/S_PPE_EXPL_VARIANT_STR,
OBJECT_TYPE TYPE STRING,
GUID TYPE STRING,
ECN_COUNTER TYPE STRING,
VARIANT_TYPE TYPE STRING,
APPLOBJ_TYPE TYPE STRING,
NODE_GUID TYPE STRING,
NAMEID TYPE STRING,
CHANGE_NO TYPE STRING,
DELETION_FLAG TYPE STRING,
CMPID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMI/S_PPE_EXPL_VARIANT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-OBJECT_TYPE sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-GUID sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-ECN_COUNTER sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-VARIANT_TYPE sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-APPLOBJ_TYPE sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-NODE_GUID sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-NAMEID sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-CHANGE_NO sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-DELETION_FLAG sy-vline
WA_/PLMI/S_PPE_EXPL_VARIANT_STR-CMPID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.