ABAP Select data from SAP table /PLMI/V_SPC_SICN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PLMI/V_SPC_SICN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PLMI/V_SPC_SICN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PLMI/V_SPC_SICN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PLMI/V_SPC_SICN TYPE STANDARD TABLE OF /PLMI/V_SPC_SICN, WA_/PLMI/V_SPC_SICN TYPE /PLMI/V_SPC_SICN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PLMI/V_SPC_SICN> TYPE /PLMI/V_SPC_SICN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PLMI/V_SPC_SICN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PLMI/V_SPC_SICN INTO TABLE IT_/PLMI/V_SPC_SICN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PLMI/V_SPC_SICN * INTO TABLE @DATA(IT_/PLMI/V_SPC_SICN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PLMI/V_SPC_SICN INDEX 1 INTO DATA(WA_/PLMI/V_SPC_SICN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PLMI/V_SPC_SICN ASSIGNING </PLMI/V_SPC_SICN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PLMI/V_SPC_SICN>-MANDT = 1.
</PLMI/V_SPC_SICN>-AETYP = 1.
</PLMI/V_SPC_SICN>-SUBID = 1.
</PLMI/V_SPC_SICN>-AENNR = 1.
</PLMI/V_SPC_SICN>-AENST = 1.
ENDLOOP. LOOP AT IT_/PLMI/V_SPC_SICN INTO WA_/PLMI/V_SPC_SICN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PLMI/V_SPC_SICN-AENBE, sy-vline,
WA_/PLMI/V_SPC_SICN-DATUV, sy-vline,
WA_/PLMI/V_SPC_SICN-TECHV, sy-vline,
WA_/PLMI/V_SPC_SICN-ANDAT, sy-vline,
WA_/PLMI/V_SPC_SICN-ANNAM, sy-vline,
WA_/PLMI/V_SPC_SICN-AEDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PLMI/V_SPC_SICN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PLMI/V_SPC_SICN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PLMI/V_SPC_SICN INTO WA_/PLMI/V_SPC_SICN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_/PLMI/V_SPC_SICN-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/V_SPC_SICN-SUBID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PLMI/V_SPC_SICN-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/V_SPC_SICN-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field LTXSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/PLMI/V_SPC_SICN-LTXSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PLMI/V_SPC_SICN-LTXSP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PLMI/V_SPC_SICN_STR,
MANDT TYPE STRING,
AETYP TYPE STRING,
SUBID TYPE STRING,
AENNR TYPE STRING,
AENST TYPE STRING,
AENBE TYPE STRING,
DATUV TYPE STRING,
TECHV TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
AETXT TYPE STRING,
LTXSP TYPE STRING,
AEGRU TYPE STRING,
CCART TYPE STRING,
CCSTM TYPE STRING,
DYDAT TYPE STRING,
CONT1 TYPE STRING,
AEFUN TYPE STRING,
UESTR TYPE STRING,
RLKEY TYPE STRING,
LVORM TYPE STRING,
CLINT TYPE STRING,
AERNG TYPE STRING,
RLDAT TYPE STRING,
RLTIM TYPE STRING,
TEREL TYPE STRING,
NACHT TYPE STRING,
INDAT TYPE STRING,
AUDAT TYPE STRING,
FLUSE TYPE STRING,
AEDIF TYPE STRING,
ERLED TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PLMI/V_SPC_SICN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PLMI/V_SPC_SICN_STR-MANDT sy-vline
WA_/PLMI/V_SPC_SICN_STR-AETYP sy-vline
WA_/PLMI/V_SPC_SICN_STR-SUBID sy-vline
WA_/PLMI/V_SPC_SICN_STR-AENNR sy-vline
WA_/PLMI/V_SPC_SICN_STR-AENST sy-vline
WA_/PLMI/V_SPC_SICN_STR-AENBE sy-vline
WA_/PLMI/V_SPC_SICN_STR-DATUV sy-vline
WA_/PLMI/V_SPC_SICN_STR-TECHV sy-vline
WA_/PLMI/V_SPC_SICN_STR-ANDAT sy-vline
WA_/PLMI/V_SPC_SICN_STR-ANNAM sy-vline
WA_/PLMI/V_SPC_SICN_STR-AEDAT sy-vline
WA_/PLMI/V_SPC_SICN_STR-AENAM sy-vline
WA_/PLMI/V_SPC_SICN_STR-AETXT sy-vline
WA_/PLMI/V_SPC_SICN_STR-LTXSP sy-vline
WA_/PLMI/V_SPC_SICN_STR-AEGRU sy-vline
WA_/PLMI/V_SPC_SICN_STR-CCART sy-vline
WA_/PLMI/V_SPC_SICN_STR-CCSTM sy-vline
WA_/PLMI/V_SPC_SICN_STR-DYDAT sy-vline
WA_/PLMI/V_SPC_SICN_STR-CONT1 sy-vline
WA_/PLMI/V_SPC_SICN_STR-AEFUN sy-vline
WA_/PLMI/V_SPC_SICN_STR-UESTR sy-vline
WA_/PLMI/V_SPC_SICN_STR-RLKEY sy-vline
WA_/PLMI/V_SPC_SICN_STR-LVORM sy-vline
WA_/PLMI/V_SPC_SICN_STR-CLINT sy-vline
WA_/PLMI/V_SPC_SICN_STR-AERNG sy-vline
WA_/PLMI/V_SPC_SICN_STR-RLDAT sy-vline
WA_/PLMI/V_SPC_SICN_STR-RLTIM sy-vline
WA_/PLMI/V_SPC_SICN_STR-TEREL sy-vline
WA_/PLMI/V_SPC_SICN_STR-NACHT sy-vline
WA_/PLMI/V_SPC_SICN_STR-INDAT sy-vline
WA_/PLMI/V_SPC_SICN_STR-AUDAT sy-vline
WA_/PLMI/V_SPC_SICN_STR-FLUSE sy-vline
WA_/PLMI/V_SPC_SICN_STR-AEDIF sy-vline
WA_/PLMI/V_SPC_SICN_STR-ERLED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.