ABAP Select data from SAP table /PM0/ABEOIOTRESBUS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABEOIOTRESBUS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABEOIOTRESBUS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PM0/ABEOIOTRESBUS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PM0/ABEOIOTRESBUS TYPE STANDARD TABLE OF /PM0/ABEOIOTRESBUS, WA_/PM0/ABEOIOTRESBUS TYPE /PM0/ABEOIOTRESBUS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PM0/ABEOIOTRESBUS> TYPE /PM0/ABEOIOTRESBUS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PM0/ABEOIOTRESBUS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PM0/ABEOIOTRESBUS INTO TABLE IT_/PM0/ABEOIOTRESBUS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PM0/ABEOIOTRESBUS * INTO TABLE @DATA(IT_/PM0/ABEOIOTRESBUS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PM0/ABEOIOTRESBUS INDEX 1 INTO DATA(WA_/PM0/ABEOIOTRESBUS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PM0/ABEOIOTRESBUS ASSIGNING </PM0/ABEOIOTRESBUS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABEOIOTRESBUS>-/PM0/ABDOINSOBJ_OID = 1.
</PM0/ABEOIOTRESBUS>-EFFECTIVITY_DT = 1.
</PM0/ABEOIOTRESBUS>-INSOBJ_TT = 1.
</PM0/ABEOIOTRESBUS>-OBJCAT_CD = 1.
</PM0/ABEOIOTRESBUS>-OBJTYP_CD = 1.
ENDLOOP. LOOP AT IT_/PM0/ABEOIOTRESBUS INTO WA_/PM0/ABEOIOTRESBUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PM0/ABEOIOTRESBUS-INSOBJNR_TT, sy-vline,
WA_/PM0/ABEOIOTRESBUS-OBJTYPTO_ID, sy-vline,
WA_/PM0/ABEOIOTRESBUS-INSOBJECT_TT, sy-vline,
WA_/PM0/ABEOIOTRESBUS-PART_ID, sy-vline,
WA_/PM0/ABEOIOTRESBUS-CURRENCY_ID, sy-vline,
WA_/PM0/ABEOIOTRESBUS-INSDECNR_TT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABEOIOTRESBUS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABEOIOTRESBUS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABEOIOTRESBUS INTO WA_/PM0/ABEOIOTRESBUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field INSOBJNR_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-INSOBJNR_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-INSOBJNR_TT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PART_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-PART_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-PART_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INSDECNR_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-INSDECNR_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-INSDECNR_TT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EXTOBJNR_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-EXTOBJNR_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-EXTOBJNR_TT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field POSGRP_TT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-POSGRP_TT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-POSGRP_TT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PARTN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-PARTN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-PARTN_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field GLAZEDAREABUI_UT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-GLAZEDAREABUI_UT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-GLAZEDAREABUI_UT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field PROPERTYAREA_UT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-PROPERTYAREA_UT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-PROPERTYAREA_UT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field CUBICVOLUME_UT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PM0/ABEOIOTRESBUS-CUBICVOLUME_UT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABEOIOTRESBUS-CUBICVOLUME_UT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABEOIOTRESBUS_STR,
/PM0/ABDOINSOBJ_OID TYPE STRING,
EFFECTIVITY_DT TYPE STRING,
INSOBJ_TT TYPE STRING,
OBJCAT_CD TYPE STRING,
OBJTYP_CD TYPE STRING,
INSOBJNR_TT TYPE STRING,
OBJTYPTO_ID TYPE STRING,
INSOBJECT_TT TYPE STRING,
PART_ID TYPE STRING,
CURRENCY_ID TYPE STRING,
INSDECNR_TT TYPE STRING,
OBJPOSNR_TT TYPE STRING,
EXTOBJNR_TT TYPE STRING,
STATUS_ID TYPE STRING,
CANCEL_TT TYPE STRING,
CANCEL_DT TYPE STRING,
/PM0/ABDOINSOBJ_CID TYPE STRING,
CHANGEREASON_ID TYPE STRING,
CHANGEREASON_TT TYPE STRING,
CHAREATXT_TT TYPE STRING,
OBJCAT_TT TYPE STRING,
OBJGRP_TT TYPE STRING,
OBJTYP_TT TYPE STRING,
POSGRP_TT TYPE STRING,
CUSTOMER_TB_CI TYPE STRING,
YEARCONSTRUCT_DT TYPE STRING,
OUTERWALL_CD TYPE STRING,
GLAZEDAREABUI_VL TYPE STRING,
LOCBUILTAREA_FG TYPE STRING,
ROOFING_CD TYPE STRING,
PREFABRIHOUSE_FG TYPE STRING,
PROPERTYAREA_VL TYPE STRING,
CUBICVOLUME_VL TYPE STRING,
PARTN_ID TYPE STRING,
INTCOVCONF_FG TYPE STRING,
PARTNERACT_ID TYPE STRING,
GLAZEDAREABUI_UT TYPE STRING,
PROPERTYAREA_UT TYPE STRING,
CUBICVOLUME_UT TYPE STRING,
CUSTOMER_PB_CI TYPE STRING,
OUTERWALL_TT TYPE STRING,
PARTNERACT_TT TYPE STRING,
PARTNERNAME_TT TYPE STRING,
ROOFING_TT TYPE STRING,
NUMBERFLOORS_AM TYPE STRING,
NRRESIDUNITS_AM TYPE STRING,
BUILDINGTYPE_CD TYPE STRING,
BUILDINHABIT_FG TYPE STRING,
BLDKIND_ID TYPE STRING,
CUSTOMER_RESBUS_CI TYPE STRING,
BLDKIND_TT TYPE STRING,
BUILDINGTYPE_TT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABEOIOTRESBUS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-/PM0/ABDOINSOBJ_OID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-EFFECTIVITY_DT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-INSOBJ_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJCAT_CD sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJTYP_CD sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-INSOBJNR_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJTYPTO_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-INSOBJECT_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PART_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CURRENCY_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-INSDECNR_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJPOSNR_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-EXTOBJNR_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-STATUS_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CANCEL_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CANCEL_DT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-/PM0/ABDOINSOBJ_CID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CHANGEREASON_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CHANGEREASON_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CHAREATXT_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJCAT_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJGRP_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OBJTYP_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-POSGRP_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CUSTOMER_TB_CI sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-YEARCONSTRUCT_DT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OUTERWALL_CD sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-GLAZEDAREABUI_VL sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-LOCBUILTAREA_FG sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-ROOFING_CD sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PREFABRIHOUSE_FG sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PROPERTYAREA_VL sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CUBICVOLUME_VL sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PARTN_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-INTCOVCONF_FG sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PARTNERACT_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-GLAZEDAREABUI_UT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PROPERTYAREA_UT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CUBICVOLUME_UT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CUSTOMER_PB_CI sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-OUTERWALL_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PARTNERACT_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-PARTNERNAME_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-ROOFING_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-NUMBERFLOORS_AM sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-NRRESIDUNITS_AM sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-BUILDINGTYPE_CD sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-BUILDINHABIT_FG sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-BLDKIND_ID sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-CUSTOMER_RESBUS_CI sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-BLDKIND_TT sy-vline
WA_/PM0/ABEOIOTRESBUS_STR-BUILDINGTYPE_TT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.