ABAP Select data from SAP table /PM0/ABGASBTHCON2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABGASBTHCON2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABGASBTHCON2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/ABGASBTHCON2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/ABGASBTHCON2 TYPE STANDARD TABLE OF /PM0/ABGASBTHCON2,
      WA_/PM0/ABGASBTHCON2 TYPE /PM0/ABGASBTHCON2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/ABGASBTHCON2> TYPE /PM0/ABGASBTHCON2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/ABGASBTHCON2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/ABGASBTHCON2
  INTO TABLE IT_/PM0/ABGASBTHCON2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/ABGASBTHCON2
*  INTO TABLE @DATA(IT_/PM0/ABGASBTHCON22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/ABGASBTHCON2 INDEX 1 INTO DATA(WA_/PM0/ABGASBTHCON22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/ABGASBTHCON2 ASSIGNING </PM0/ABGASBTHCON2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABGASBTHCON2>-/PM0/ABEASBTHCON2_OID = 1.
</PM0/ABGASBTHCON2>-/PM0/ABDASBCHCON2_OID = 1.
</PM0/ABGASBTHCON2>-LONGITUDE2_CD = 1.
</PM0/ABGASBTHCON2>-LONGITUDEM2_CD = 1.
</PM0/ABGASBTHCON2>-LONGITUDES2_CD = 1.
ENDLOOP.

LOOP AT IT_/PM0/ABGASBTHCON2 INTO WA_/PM0/ABGASBTHCON2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/ABGASBTHCON2-LATITUDE2_CD, sy-vline,
WA_/PM0/ABGASBTHCON2-LATITUDEM2_CD, sy-vline,
WA_/PM0/ABGASBTHCON2-LATITUDES2_CD, sy-vline,
WA_/PM0/ABGASBTHCON2-POST_CODE12, sy-vline,
WA_/PM0/ABGASBTHCON2-STREET2, sy-vline,
WA_/PM0/ABGASBTHCON2-COUNTRY2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABGASBTHCON2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABGASBTHCON2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABGASBTHCON2 INTO WA_/PM0/ABGASBTHCON2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABGASBTHCON2_STR,
/PM0/ABEASBTHCON2_OID TYPE STRING,
/PM0/ABDASBCHCON2_OID TYPE STRING,
LONGITUDE2_CD TYPE STRING,
LONGITUDEM2_CD TYPE STRING,
LONGITUDES2_CD TYPE STRING,
LATITUDE2_CD TYPE STRING,
LATITUDEM2_CD TYPE STRING,
LATITUDES2_CD TYPE STRING,
POST_CODE12 TYPE STRING,
STREET2 TYPE STRING,
COUNTRY2 TYPE STRING,
BUILTYPECLASS2_CD TYPE STRING,
CITY12 TYPE STRING,
HOUSE_NUM12 TYPE STRING,
GLAZEDAREABU2_VL TYPE STRING,
INTCOVCONF2_FG TYPE STRING,
INTERIORGLAZ2_VL TYPE STRING,
LOCBUILTAREA2_FG TYPE STRING,
OUTERWALL2_CD TYPE STRING,
PREFABRIHOUS2_FG TYPE STRING,
RESIDENTSPAC2_VL TYPE STRING,
ROOFING2_CD TYPE STRING,
GLAZEDAREABU2_UT TYPE STRING,
RESIDENTSPAC2_UT TYPE STRING,
INTERIORGLAZ2_UT TYPE STRING,
PARTN2_ID TYPE STRING,
PARTNERACT2_ID TYPE STRING,
REGION_CD TYPE STRING,
TIMEZONE_TT TYPE STRING,
CUSTOMER_HCON2_CI TYPE STRING,
BUILTYPECLAS2_TT TYPE STRING,
OUTERWALL2_TT TYPE STRING,
PARTNERNAME_TT TYPE STRING,
ROOFING2_TT TYPE STRING,
/PM0/ABDASBTHCON2_OID TYPE STRING,
HAZARDCLAS2_CD TYPE STRING,
TARIFFZONE2_CD TYPE STRING,
ALARMSYSTE2_FG TYPE STRING,
BLDKIND2_ID TYPE STRING,
CUSTOMER_CON2_CI TYPE STRING,
BLDKIND2_TT TYPE STRING,
HAZARDCLAS2_TT TYPE STRING,
/PM0/ABDASUBJCT_OID TYPE STRING,
PARTNER_ID TYPE STRING,
ROLECD_CD TYPE STRING,
EFFECTIVITY_DT TYPE STRING,
OBJCAT_CD TYPE STRING,
OBJTYP_CD TYPE STRING,
INSOBJNR_TT TYPE STRING,
ACCUMULATNR_TT TYPE STRING,
AWARDREASON_CD TYPE STRING,
UPDATEREQUIRE_FG TYPE STRING,
TYPCHANSTRUK_TT TYPE STRING,
CATCHANSTRUK_TT TYPE STRING,
SUPCHANSTRUK_TT TYPE STRING,
JOURVBO_CD TYPE STRING,
PM_ID TYPE STRING,
CURRENCY_ID TYPE STRING,
INSDECNR_TT TYPE STRING,
OBJPOSNR_TT TYPE STRING,
RI_OBJ_GD TYPE STRING,
NOPREMRAISE_FG TYPE STRING,
LOCCHANGE_FG TYPE STRING,
RISKGROUPNR_TT TYPE STRING,
CUSTOMER_PB_CI TYPE STRING,
/PM0/ABDASUBJCT_CID TYPE STRING,
ADRESSE_TT TYPE STRING,
AWARDREASON_TT TYPE STRING,
COMMENTCOV_TT TYPE STRING,
COMMENTPOLPR_TT TYPE STRING,
COMMENT_TT TYPE STRING,
EXTOBJNR_TT TYPE STRING,
INFLRIDPM2_ID TYPE STRING,
INFLRIDPM2_TT TYPE STRING,
INFLRIDPM_ID TYPE STRING,
INFLRIDPM_TT TYPE STRING,
INSDEC_TT TYPE STRING,
INSOBJ_TT TYPE STRING,
NAME_TT TYPE STRING,
OBJCAT_TT TYPE STRING,
OBJTYP_TT TYPE STRING,
PBSTYP_TT TYPE STRING,
PM_TT TYPE STRING,
SUBJECT_TD TYPE STRING,
SYNCHRONOUS_FG TYPE STRING,
CUSTOMER_TB_CI TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABGASBTHCON2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABGASBTHCON2_STR-/PM0/ABEASBTHCON2_OID sy-vline
WA_/PM0/ABGASBTHCON2_STR-/PM0/ABDASBCHCON2_OID sy-vline
WA_/PM0/ABGASBTHCON2_STR-LONGITUDE2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-LONGITUDEM2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-LONGITUDES2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-LATITUDE2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-LATITUDEM2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-LATITUDES2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-POST_CODE12 sy-vline
WA_/PM0/ABGASBTHCON2_STR-STREET2 sy-vline
WA_/PM0/ABGASBTHCON2_STR-COUNTRY2 sy-vline
WA_/PM0/ABGASBTHCON2_STR-BUILTYPECLASS2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-CITY12 sy-vline
WA_/PM0/ABGASBTHCON2_STR-HOUSE_NUM12 sy-vline
WA_/PM0/ABGASBTHCON2_STR-GLAZEDAREABU2_VL sy-vline
WA_/PM0/ABGASBTHCON2_STR-INTCOVCONF2_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-INTERIORGLAZ2_VL sy-vline
WA_/PM0/ABGASBTHCON2_STR-LOCBUILTAREA2_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-OUTERWALL2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-PREFABRIHOUS2_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-RESIDENTSPAC2_VL sy-vline
WA_/PM0/ABGASBTHCON2_STR-ROOFING2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-GLAZEDAREABU2_UT sy-vline
WA_/PM0/ABGASBTHCON2_STR-RESIDENTSPAC2_UT sy-vline
WA_/PM0/ABGASBTHCON2_STR-INTERIORGLAZ2_UT sy-vline
WA_/PM0/ABGASBTHCON2_STR-PARTN2_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-PARTNERACT2_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-REGION_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-TIMEZONE_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-CUSTOMER_HCON2_CI sy-vline
WA_/PM0/ABGASBTHCON2_STR-BUILTYPECLAS2_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-OUTERWALL2_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-PARTNERNAME_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-ROOFING2_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-/PM0/ABDASBTHCON2_OID sy-vline
WA_/PM0/ABGASBTHCON2_STR-HAZARDCLAS2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-TARIFFZONE2_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-ALARMSYSTE2_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-BLDKIND2_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-CUSTOMER_CON2_CI sy-vline
WA_/PM0/ABGASBTHCON2_STR-BLDKIND2_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-HAZARDCLAS2_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-/PM0/ABDASUBJCT_OID sy-vline
WA_/PM0/ABGASBTHCON2_STR-PARTNER_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-ROLECD_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-EFFECTIVITY_DT sy-vline
WA_/PM0/ABGASBTHCON2_STR-OBJCAT_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-OBJTYP_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-INSOBJNR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-ACCUMULATNR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-AWARDREASON_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-UPDATEREQUIRE_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-TYPCHANSTRUK_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-CATCHANSTRUK_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-SUPCHANSTRUK_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-JOURVBO_CD sy-vline
WA_/PM0/ABGASBTHCON2_STR-PM_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-CURRENCY_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-INSDECNR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-OBJPOSNR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-RI_OBJ_GD sy-vline
WA_/PM0/ABGASBTHCON2_STR-NOPREMRAISE_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-LOCCHANGE_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-RISKGROUPNR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-CUSTOMER_PB_CI sy-vline
WA_/PM0/ABGASBTHCON2_STR-/PM0/ABDASUBJCT_CID sy-vline
WA_/PM0/ABGASBTHCON2_STR-ADRESSE_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-AWARDREASON_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-COMMENTCOV_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-COMMENTPOLPR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-COMMENT_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-EXTOBJNR_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-INFLRIDPM2_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-INFLRIDPM2_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-INFLRIDPM_ID sy-vline
WA_/PM0/ABGASBTHCON2_STR-INFLRIDPM_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-INSDEC_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-INSOBJ_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-NAME_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-OBJCAT_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-OBJTYP_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-PBSTYP_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-PM_TT sy-vline
WA_/PM0/ABGASBTHCON2_STR-SUBJECT_TD sy-vline
WA_/PM0/ABGASBTHCON2_STR-SYNCHRONOUS_FG sy-vline
WA_/PM0/ABGASBTHCON2_STR-CUSTOMER_TB_CI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.