ABAP Select data from SAP table /PM0/ABOIGENHEADER into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABOIGENHEADER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABOIGENHEADER. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PM0/ABOIGENHEADER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PM0/ABOIGENHEADER TYPE STANDARD TABLE OF /PM0/ABOIGENHEADER, WA_/PM0/ABOIGENHEADER TYPE /PM0/ABOIGENHEADER, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PM0/ABOIGENHEADER> TYPE /PM0/ABOIGENHEADER. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PM0/ABOIGENHEADER. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PM0/ABOIGENHEADER INTO TABLE IT_/PM0/ABOIGENHEADER. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PM0/ABOIGENHEADER * INTO TABLE @DATA(IT_/PM0/ABOIGENHEADER2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PM0/ABOIGENHEADER INDEX 1 INTO DATA(WA_/PM0/ABOIGENHEADER2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PM0/ABOIGENHEADER ASSIGNING </PM0/ABOIGENHEADER>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABOIGENHEADER>-WZTYPE = 1.
</PM0/ABOIGENHEADER>-OBJAP = 1.
</PM0/ABOIGENHEADER>-WIZ_USE_SYSTEMTYPE = 1.
</PM0/ABOIGENHEADER>-LANGUAGE = 1.
</PM0/ABOIGENHEADER>-INSOBJCAT = 1.
ENDLOOP. LOOP AT IT_/PM0/ABOIGENHEADER INTO WA_/PM0/ABOIGENHEADER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PM0/ABOIGENHEADER-INSOBJCAT_DESCR, sy-vline,
WA_/PM0/ABOIGENHEADER-SUFFIX, sy-vline,
WA_/PM0/ABOIGENHEADER-ADDRESS_RELEVANT, sy-vline,
WA_/PM0/ABOIGENHEADER-INSOBJRELEV_FG, sy-vline,
WA_/PM0/ABOIGENHEADER-INSOBJTYPE, sy-vline,
WA_/PM0/ABOIGENHEADER-INSOBJTYPE_DESCR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABOIGENHEADER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABOIGENHEADER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABOIGENHEADER INTO WA_/PM0/ABOIGENHEADER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/PM0/ABOIGENHEADER-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABOIGENHEADER-LANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABOIGENHEADER_STR,
WZTYPE TYPE STRING,
OBJAP TYPE STRING,
WIZ_USE_SYSTEMTYPE TYPE STRING,
LANGUAGE TYPE STRING,
INSOBJCAT TYPE STRING,
INSOBJCAT_DESCR TYPE STRING,
SUFFIX TYPE STRING,
ADDRESS_RELEVANT TYPE STRING,
INSOBJRELEV_FG TYPE STRING,
INSOBJTYPE TYPE STRING,
INSOBJTYPE_DESCR TYPE STRING,
INSOBJCAT_CHANNEL_STRUCTURE TYPE STRING,
INSOBJCAT_CHANNELMODEL TYPE STRING,
INSOBJCAT_FLD_MOD_STRUCT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABOIGENHEADER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABOIGENHEADER_STR-WZTYPE sy-vline
WA_/PM0/ABOIGENHEADER_STR-OBJAP sy-vline
WA_/PM0/ABOIGENHEADER_STR-WIZ_USE_SYSTEMTYPE sy-vline
WA_/PM0/ABOIGENHEADER_STR-LANGUAGE sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJCAT sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJCAT_DESCR sy-vline
WA_/PM0/ABOIGENHEADER_STR-SUFFIX sy-vline
WA_/PM0/ABOIGENHEADER_STR-ADDRESS_RELEVANT sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJRELEV_FG sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJTYPE sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJTYPE_DESCR sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJCAT_CHANNEL_STRUCTURE sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJCAT_CHANNELMODEL sy-vline
WA_/PM0/ABOIGENHEADER_STR-INSOBJCAT_FLD_MOD_STRUCT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.