ABAP Select data from SAP table /PM0/ABT_SVC_SCVCOV_CRT_P into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PM0/ABT_SVC_SCVCOV_CRT_P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PM0/ABT_SVC_SCVCOV_CRT_P. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /PM0/ABT_SVC_SCVCOV_CRT_P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/PM0/ABT_SVC_SCVCOV_CRT_P TYPE STANDARD TABLE OF /PM0/ABT_SVC_SCVCOV_CRT_P,
      WA_/PM0/ABT_SVC_SCVCOV_CRT_P TYPE /PM0/ABT_SVC_SCVCOV_CRT_P,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </PM0/ABT_SVC_SCVCOV_CRT_P> TYPE /PM0/ABT_SVC_SCVCOV_CRT_P.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/PM0/ABT_SVC_SCVCOV_CRT_P.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /PM0/ABT_SVC_SCVCOV_CRT_P
  INTO TABLE IT_/PM0/ABT_SVC_SCVCOV_CRT_P.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /PM0/ABT_SVC_SCVCOV_CRT_P
*  INTO TABLE @DATA(IT_/PM0/ABT_SVC_SCVCOV_CRT_P2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/PM0/ABT_SVC_SCVCOV_CRT_P INDEX 1 INTO DATA(WA_/PM0/ABT_SVC_SCVCOV_CRT_P2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/PM0/ABT_SVC_SCVCOV_CRT_P ASSIGNING </PM0/ABT_SVC_SCVCOV_CRT_P>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</PM0/ABT_SVC_SCVCOV_CRT_P>-ANNUITYTP_CD = 1.
</PM0/ABT_SVC_SCVCOV_CRT_P>-BASEAMOUNCALC_FG = 1.
</PM0/ABT_SVC_SCVCOV_CRT_P>-BASEAMOUNT_AM = 1.
</PM0/ABT_SVC_SCVCOV_CRT_P>-COVVARIANT_CD = 1.
</PM0/ABT_SVC_SCVCOV_CRT_P>-FRACINSAMOUNT_CD = 1.
ENDLOOP.

LOOP AT IT_/PM0/ABT_SVC_SCVCOV_CRT_P INTO WA_/PM0/ABT_SVC_SCVCOV_CRT_P.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/PM0/ABT_SVC_SCVCOV_CRT_P-INSAMOUNT_AM, sy-vline,
WA_/PM0/ABT_SVC_SCVCOV_CRT_P-INSAMOUNT_VL, sy-vline,
WA_/PM0/ABT_SVC_SCVCOV_CRT_P-INSAMTP_CD, sy-vline,
WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PML_AM, sy-vline,
WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PML_VL, sy-vline,
WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PROBATNPRD_VL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PM0/ABT_SVC_SCVCOV_CRT_P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PM0/ABT_SVC_SCVCOV_CRT_P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PM0/ABT_SVC_SCVCOV_CRT_P INTO WA_/PM0/ABT_SVC_SCVCOV_CRT_P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit J7NUM, internal->external for field ANNUITYTP_CD CALL FUNCTION 'CONVERSION_EXIT_J7NUM_OUTPUT' EXPORTING input = WA_/PM0/ABT_SVC_SCVCOV_CRT_P-ANNUITYTP_CD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABT_SVC_SCVCOV_CRT_P-ANNUITYTP_CD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit J7NUM, internal->external for field PROBATNPRD_VL CALL FUNCTION 'CONVERSION_EXIT_J7NUM_OUTPUT' EXPORTING input = WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PROBATNPRD_VL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PROBATNPRD_VL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit J7NUM, internal->external for field PROGRESSTYPE_CD CALL FUNCTION 'CONVERSION_EXIT_J7NUM_OUTPUT' EXPORTING input = WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PROGRESSTYPE_CD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PM0/ABT_SVC_SCVCOV_CRT_P-PROGRESSTYPE_CD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PM0/ABT_SVC_SCVCOV_CRT_P_STR,
ANNUITYTP_CD TYPE STRING,
BASEAMOUNCALC_FG TYPE STRING,
BASEAMOUNT_AM TYPE STRING,
COVVARIANT_CD TYPE STRING,
FRACINSAMOUNT_CD TYPE STRING,
INSAMOUNT_AM TYPE STRING,
INSAMOUNT_VL TYPE STRING,
INSAMTP_CD TYPE STRING,
PML_AM TYPE STRING,
PML_VL TYPE STRING,
PROBATNPRD_VL TYPE STRING,
PROGRESSTYPE_CD TYPE STRING,
RICHECK_FG TYPE STRING,
SCHEDCOMP_CD TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-ANNUITYTP_CD sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-BASEAMOUNCALC_FG sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-BASEAMOUNT_AM sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-COVVARIANT_CD sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-FRACINSAMOUNT_CD sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-INSAMOUNT_AM sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-INSAMOUNT_VL sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-INSAMTP_CD sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-PML_AM sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-PML_VL sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-PROBATNPRD_VL sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-PROGRESSTYPE_CD sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-RICHECK_FG sy-vline
WA_/PM0/ABT_SVC_SCVCOV_CRT_P_STR-SCHEDCOMP_CD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.