ABAP Select data from SAP table /PRA/S_AK_PROC_TC_3306 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PRA/S_AK_PROC_TC_3306 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PRA/S_AK_PROC_TC_3306. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PRA/S_AK_PROC_TC_3306 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PRA/S_AK_PROC_TC_3306 TYPE STANDARD TABLE OF /PRA/S_AK_PROC_TC_3306, WA_/PRA/S_AK_PROC_TC_3306 TYPE /PRA/S_AK_PROC_TC_3306, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PRA/S_AK_PROC_TC_3306> TYPE /PRA/S_AK_PROC_TC_3306. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PRA/S_AK_PROC_TC_3306. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PRA/S_AK_PROC_TC_3306 INTO TABLE IT_/PRA/S_AK_PROC_TC_3306. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PRA/S_AK_PROC_TC_3306 * INTO TABLE @DATA(IT_/PRA/S_AK_PROC_TC_33062). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PRA/S_AK_PROC_TC_3306 INDEX 1 INTO DATA(WA_/PRA/S_AK_PROC_TC_33062). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PRA/S_AK_PROC_TC_3306 ASSIGNING </PRA/S_AK_PROC_TC_3306>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PRA/S_AK_PROC_TC_3306>-MANDT = 1.
</PRA/S_AK_PROC_TC_3306>-RUN_ID = 1.
</PRA/S_AK_PROC_TC_3306>-CHECK_NO = 1.
</PRA/S_AK_PROC_TC_3306>-OWN_NO = 1.
</PRA/S_AK_PROC_TC_3306>-VNAME = 1.
ENDLOOP. LOOP AT IT_/PRA/S_AK_PROC_TC_3306 INTO WA_/PRA/S_AK_PROC_TC_3306. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PRA/S_AK_PROC_TC_3306-DOI_NO, sy-vline,
WA_/PRA/S_AK_PROC_TC_3306-WL_NO, sy-vline,
WA_/PRA/S_AK_PROC_TC_3306-WC_NO, sy-vline,
WA_/PRA/S_AK_PROC_TC_3306-OWN_INT_TYPE_SEQ, sy-vline,
WA_/PRA/S_AK_PROC_TC_3306-SALE_DT, sy-vline,
WA_/PRA/S_AK_PROC_TC_3306-PD_CD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PRA/S_AK_PROC_TC_3306 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PRA/S_AK_PROC_TC_3306 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PRA/S_AK_PROC_TC_3306 INTO WA_/PRA/S_AK_PROC_TC_3306. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field OWN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-OWN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-OWN_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-VNAME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DOI_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-DOI_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-DOI_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-WL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-WL_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WC_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-WC_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-WC_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-SAKNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit OIUMY, internal->external for field ACCT_PERIOD CALL FUNCTION 'CONVERSION_EXIT_OIUMY_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-ACCT_PERIOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-ACCT_PERIOD.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DN_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-DN_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-DN_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field UNIT_VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-UNIT_VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-UNIT_VNAME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-VOL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-VOL_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ENERGY_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-ENERGY_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-ENERGY_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field HEAT_VAL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/PRA/S_AK_PROC_TC_3306-HEAT_VAL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/PRA/S_AK_PROC_TC_3306-HEAT_VAL_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PRA/S_AK_PROC_TC_3306_STR,
MANDT TYPE STRING,
RUN_ID TYPE STRING,
CHECK_NO TYPE STRING,
OWN_NO TYPE STRING,
VNAME TYPE STRING,
DOI_NO TYPE STRING,
WL_NO TYPE STRING,
WC_NO TYPE STRING,
OWN_INT_TYPE_SEQ TYPE STRING,
SALE_DT TYPE STRING,
PD_CD TYPE STRING,
DISB_DECIMAL TYPE STRING,
SAKNR TYPE STRING,
RECORD_TYPE TYPE STRING,
BUKRS TYPE STRING,
ACCT_PERIOD TYPE STRING,
NRI_DECIMAL TYPE STRING,
DN_NO TYPE STRING,
LAND1 TYPE STRING,
REGIO TYPE STRING,
COUNC TYPE STRING,
UNIT_VNAME TYPE STRING,
VOL_UOM TYPE STRING,
ENERGY_UOM TYPE STRING,
SUS_RSN_CD TYPE STRING,
PPA_RSN_CD TYPE STRING,
AES_CD TYPE STRING,
GROSS_VOL TYPE STRING,
GROSS_VAL TYPE STRING,
OWNER_GROSS_VAL TYPE STRING,
NET_VAL TYPE STRING,
NET_VOL TYPE STRING,
GROSS_ENERGY TYPE STRING,
OWNER_ENERGY TYPE STRING,
GROSS_TOT_MKT TYPE STRING,
GROSS_TOT_TAXES TYPE STRING,
OWNER_TOT_MKT TYPE STRING,
OWNER_TOT_TAXES TYPE STRING,
OWNER_TOT_OTHER TYPE STRING,
GRS_LESS_TAX_MKT TYPE STRING,
HEAT_VAL TYPE STRING,
HEAT_VAL_UOM TYPE STRING,
PRICE TYPE STRING,
CHECK_DT TYPE STRING,
OIU_CRUSER TYPE STRING,
OIU_TIMESTAMP TYPE STRING,
BAL_GUID TYPE STRING,
SEL TYPE STRING,
PB_SHOW_CHK_ADJ TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PRA/S_AK_PROC_TC_3306_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-MANDT sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-RUN_ID sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-CHECK_NO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWN_NO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-VNAME sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-DOI_NO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-WL_NO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-WC_NO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWN_INT_TYPE_SEQ sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-SALE_DT sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-PD_CD sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-DISB_DECIMAL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-SAKNR sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-RECORD_TYPE sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-BUKRS sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-ACCT_PERIOD sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-NRI_DECIMAL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-DN_NO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-LAND1 sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-REGIO sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-COUNC sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-UNIT_VNAME sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-VOL_UOM sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-ENERGY_UOM sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-SUS_RSN_CD sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-PPA_RSN_CD sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-AES_CD sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-GROSS_VOL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-GROSS_VAL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWNER_GROSS_VAL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-NET_VAL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-NET_VOL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-GROSS_ENERGY sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWNER_ENERGY sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-GROSS_TOT_MKT sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-GROSS_TOT_TAXES sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWNER_TOT_MKT sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWNER_TOT_TAXES sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OWNER_TOT_OTHER sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-GRS_LESS_TAX_MKT sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-HEAT_VAL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-HEAT_VAL_UOM sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-PRICE sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-CHECK_DT sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OIU_CRUSER sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-OIU_TIMESTAMP sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-BAL_GUID sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-SEL sy-vline
WA_/PRA/S_AK_PROC_TC_3306_STR-PB_SHOW_CHK_ADJ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.