ABAP Select data from SAP table /PRA/S_TA_RP21PD_NONKEY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /PRA/S_TA_RP21PD_NONKEY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /PRA/S_TA_RP21PD_NONKEY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /PRA/S_TA_RP21PD_NONKEY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/PRA/S_TA_RP21PD_NONKEY TYPE STANDARD TABLE OF /PRA/S_TA_RP21PD_NONKEY, WA_/PRA/S_TA_RP21PD_NONKEY TYPE /PRA/S_TA_RP21PD_NONKEY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </PRA/S_TA_RP21PD_NONKEY> TYPE /PRA/S_TA_RP21PD_NONKEY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/PRA/S_TA_RP21PD_NONKEY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /PRA/S_TA_RP21PD_NONKEY INTO TABLE IT_/PRA/S_TA_RP21PD_NONKEY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /PRA/S_TA_RP21PD_NONKEY * INTO TABLE @DATA(IT_/PRA/S_TA_RP21PD_NONKEY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/PRA/S_TA_RP21PD_NONKEY INDEX 1 INTO DATA(WA_/PRA/S_TA_RP21PD_NONKEY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/PRA/S_TA_RP21PD_NONKEY ASSIGNING </PRA/S_TA_RP21PD_NONKEY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</PRA/S_TA_RP21PD_NONKEY>-OWNERSHIP_PERC = 1.
</PRA/S_TA_RP21PD_NONKEY>-REV_PRCS_CD = 1.
</PRA/S_TA_RP21PD_NONKEY>-GROSS_BBLS_OIL = 1.
</PRA/S_TA_RP21PD_NONKEY>-EXEMPT_BBLS_OIL = 1.
</PRA/S_TA_RP21PD_NONKEY>-GROSS_MCF_GAS = 1.
ENDLOOP. LOOP AT IT_/PRA/S_TA_RP21PD_NONKEY INTO WA_/PRA/S_TA_RP21PD_NONKEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/PRA/S_TA_RP21PD_NONKEY-EXEMPT_MCF_GAS, sy-vline,
WA_/PRA/S_TA_RP21PD_NONKEY-TRANSPORTATION, sy-vline,
WA_/PRA/S_TA_RP21PD_NONKEY-PROC_MANU, sy-vline,
WA_/PRA/S_TA_RP21PD_NONKEY-AD_VALOREM_TAX, sy-vline,
WA_/PRA/S_TA_RP21PD_NONKEY-GROSS_INCOME, sy-vline,
WA_/PRA/S_TA_RP21PD_NONKEY-GROSS_INCOME_STR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/PRA/S_TA_RP21PD_NONKEY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/PRA/S_TA_RP21PD_NONKEY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/PRA/S_TA_RP21PD_NONKEY INTO WA_/PRA/S_TA_RP21PD_NONKEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/PRA/S_TA_RP21PD_NONKEY_STR,
OWNERSHIP_PERC TYPE STRING,
REV_PRCS_CD TYPE STRING,
GROSS_BBLS_OIL TYPE STRING,
EXEMPT_BBLS_OIL TYPE STRING,
GROSS_MCF_GAS TYPE STRING,
EXEMPT_MCF_GAS TYPE STRING,
TRANSPORTATION TYPE STRING,
PROC_MANU TYPE STRING,
AD_VALOREM_TAX TYPE STRING,
GROSS_INCOME TYPE STRING,
GROSS_INCOME_STR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/PRA/S_TA_RP21PD_NONKEY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-OWNERSHIP_PERC sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-REV_PRCS_CD sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-GROSS_BBLS_OIL sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-EXEMPT_BBLS_OIL sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-GROSS_MCF_GAS sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-EXEMPT_MCF_GAS sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-TRANSPORTATION sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-PROC_MANU sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-AD_VALOREM_TAX sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-GROSS_INCOME sy-vline
WA_/PRA/S_TA_RP21PD_NONKEY_STR-GROSS_INCOME_STR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.