ABAP Select data from SAP table /SAPAPO/CTM_MATINLOC_IO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPAPO/CTM_MATINLOC_IO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPAPO/CTM_MATINLOC_IO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SAPAPO/CTM_MATINLOC_IO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SAPAPO/CTM_MATINLOC_IO TYPE STANDARD TABLE OF /SAPAPO/CTM_MATINLOC_IO, WA_/SAPAPO/CTM_MATINLOC_IO TYPE /SAPAPO/CTM_MATINLOC_IO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SAPAPO/CTM_MATINLOC_IO> TYPE /SAPAPO/CTM_MATINLOC_IO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SAPAPO/CTM_MATINLOC_IO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SAPAPO/CTM_MATINLOC_IO INTO TABLE IT_/SAPAPO/CTM_MATINLOC_IO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SAPAPO/CTM_MATINLOC_IO * INTO TABLE @DATA(IT_/SAPAPO/CTM_MATINLOC_IO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SAPAPO/CTM_MATINLOC_IO INDEX 1 INTO DATA(WA_/SAPAPO/CTM_MATINLOC_IO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SAPAPO/CTM_MATINLOC_IO ASSIGNING </SAPAPO/CTM_MATINLOC_IO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPAPO/CTM_MATINLOC_IO>-MATID = 1.
</SAPAPO/CTM_MATINLOC_IO>-LOCID = 1.
</SAPAPO/CTM_MATINLOC_IO>-MATNR = 1.
</SAPAPO/CTM_MATINLOC_IO>-LOCNO = 1.
</SAPAPO/CTM_MATINLOC_IO>-MEINS = 1.
ENDLOOP. LOOP AT IT_/SAPAPO/CTM_MATINLOC_IO INTO WA_/SAPAPO/CTM_MATINLOC_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SAPAPO/CTM_MATINLOC_IO-BSTMI, sy-vline,
WA_/SAPAPO/CTM_MATINLOC_IO-BSTMA, sy-vline,
WA_/SAPAPO/CTM_MATINLOC_IO-BSTFE, sy-vline,
WA_/SAPAPO/CTM_MATINLOC_IO-BSTRF, sy-vline,
WA_/SAPAPO/CTM_MATINLOC_IO-AUSS, sy-vline,
WA_/SAPAPO/CTM_MATINLOC_IO-BESKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPAPO/CTM_MATINLOC_IO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPAPO/CTM_MATINLOC_IO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPAPO/CTM_MATINLOC_IO INTO WA_/SAPAPO/CTM_MATINLOC_IO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SAPAPO/CTM_MATINLOC_IO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/CTM_MATINLOC_IO-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/CTM_MATINLOC_IO-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/CTM_MATINLOC_IO-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PMATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SAPAPO/CTM_MATINLOC_IO-PMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/CTM_MATINLOC_IO-PMATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPAPO/CTM_MATINLOC_IO_STR,
MATID TYPE STRING,
LOCID TYPE STRING,
MATNR TYPE STRING,
LOCNO TYPE STRING,
MEINS TYPE STRING,
BSTMI TYPE STRING,
BSTMA TYPE STRING,
BSTFE TYPE STRING,
BSTRF TYPE STRING,
AUSS TYPE STRING,
BESKZ TYPE STRING,
RRP_TYPE TYPE STRING,
PLIFZHORZ TYPE STRING,
GRPRT TYPE STRING,
GIPRT TYPE STRING,
SBDKZ TYPE STRING,
PRODHORZ TYPE STRING,
SHIPHORZ TYPE STRING,
CONHAP TYPE STRING,
CONHAP_OUT TYPE STRING,
KZKFG TYPE STRING,
CRITICAL_COMP TYPE STRING,
SHELF_LIFE_FLAG TYPE STRING,
SHELF_LIFE_DUR TYPE STRING,
MATURITY_DUR TYPE STRING,
SHLF_LFE_REQ_MIN TYPE STRING,
SHLF_LFE_REQ_MAX TYPE STRING,
MHDLP TYPE STRING,
PLIFZHORZ_DATE TYPE STRING,
PLIFZHORZ_TIME TYPE STRING,
PRODHORZ_DATE TYPE STRING,
PRODHORZ_TIME TYPE STRING,
SHIPHORZ_DATE TYPE STRING,
SHIPHORZ_TIME TYPE STRING,
MATLOCID TYPE STRING,
PLIFZ TYPE STRING,
PRODH TYPE STRING,
SHIPH TYPE STRING,
WHATBOM TYPE STRING,
HIER_LVL TYPE STRING,
PMATID TYPE STRING,
PLOCID TYPE STRING,
PMATNR TYPE STRING,
PLOCNO TYPE STRING,
MSGKEY TYPE STRING,
MSGTY TYPE STRING,
AGGOBJ TYPE STRING,
OBJID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPAPO/CTM_MATINLOC_IO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MATID sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-LOCID sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MATNR sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-LOCNO sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MEINS sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-BSTMI sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-BSTMA sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-BSTFE sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-BSTRF sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-AUSS sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-BESKZ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-RRP_TYPE sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PLIFZHORZ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-GRPRT sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-GIPRT sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SBDKZ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PRODHORZ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHIPHORZ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-CONHAP sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-CONHAP_OUT sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-KZKFG sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-CRITICAL_COMP sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHELF_LIFE_FLAG sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHELF_LIFE_DUR sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MATURITY_DUR sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHLF_LFE_REQ_MIN sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHLF_LFE_REQ_MAX sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MHDLP sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PLIFZHORZ_DATE sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PLIFZHORZ_TIME sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PRODHORZ_DATE sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PRODHORZ_TIME sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHIPHORZ_DATE sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHIPHORZ_TIME sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MATLOCID sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PLIFZ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PRODH sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-SHIPH sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-WHATBOM sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-HIER_LVL sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PMATID sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PLOCID sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PMATNR sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-PLOCNO sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MSGKEY sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-MSGTY sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-AGGOBJ sy-vline
WA_/SAPAPO/CTM_MATINLOC_IO_STR-OBJID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.