ABAP Select data from SAP table /SAPAPO/PUIA_PD_PARTINFO_STR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPAPO/PUIA_PD_PARTINFO_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPAPO/PUIA_PD_PARTINFO_STR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPAPO/PUIA_PD_PARTINFO_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPAPO/PUIA_PD_PARTINFO_STR TYPE STANDARD TABLE OF /SAPAPO/PUIA_PD_PARTINFO_STR,
      WA_/SAPAPO/PUIA_PD_PARTINFO_STR TYPE /SAPAPO/PUIA_PD_PARTINFO_STR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPAPO/PUIA_PD_PARTINFO_STR> TYPE /SAPAPO/PUIA_PD_PARTINFO_STR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPAPO/PUIA_PD_PARTINFO_STR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPAPO/PUIA_PD_PARTINFO_STR
  INTO TABLE IT_/SAPAPO/PUIA_PD_PARTINFO_STR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPAPO/PUIA_PD_PARTINFO_STR
*  INTO TABLE @DATA(IT_/SAPAPO/PUIA_PD_PARTINFO_STR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPAPO/PUIA_PD_PARTINFO_STR INDEX 1 INTO DATA(WA_/SAPAPO/PUIA_PD_PARTINFO_STR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPAPO/PUIA_PD_PARTINFO_STR ASSIGNING </SAPAPO/PUIA_PD_PARTINFO_STR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPAPO/PUIA_PD_PARTINFO_STR>-BODID_CURR = 1.
</SAPAPO/PUIA_PD_PARTINFO_STR>-VALFRDATE_CURRENT = 1.
</SAPAPO/PUIA_PD_PARTINFO_STR>-BODID_FUTURE = 1.
</SAPAPO/PUIA_PD_PARTINFO_STR>-VALFRDATE_FUTURE = 1.
</SAPAPO/PUIA_PD_PARTINFO_STR>-PRD_STARTDT = 1.
ENDLOOP.

LOOP AT IT_/SAPAPO/PUIA_PD_PARTINFO_STR INTO WA_/SAPAPO/PUIA_PD_PARTINFO_STR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPAPO/PUIA_PD_PARTINFO_STR-PRD_ENDDT, sy-vline,
WA_/SAPAPO/PUIA_PD_PARTINFO_STR-NEWPROD_INDI, sy-vline,
WA_/SAPAPO/PUIA_PD_PARTINFO_STR-NEWMODEL_INDI, sy-vline,
WA_/SAPAPO/PUIA_PD_PARTINFO_STR-RECALL_STARTDT, sy-vline,
WA_/SAPAPO/PUIA_PD_PARTINFO_STR-RECALL_ENDDT, sy-vline,
WA_/SAPAPO/PUIA_PD_PARTINFO_STR-WTY_STARTDT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPAPO/PUIA_PD_PARTINFO_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPAPO/PUIA_PD_PARTINFO_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPAPO/PUIA_PD_PARTINFO_STR INTO WA_/SAPAPO/PUIA_PD_PARTINFO_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/PUIA_PD_PARTINFO_STR-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/PUIA_PD_PARTINFO_STR-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEABM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/PUIA_PD_PARTINFO_STR-MEABM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/PUIA_PD_PARTINFO_STR-MEABM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/PUIA_PD_PARTINFO_STR-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/PUIA_PD_PARTINFO_STR-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SAPAPO/PUIA_PD_PARTINFO_STR-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPAPO/PUIA_PD_PARTINFO_STR-MEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPAPO/PUIA_PD_PARTINFO_STR_STR,
BODID_CURR TYPE STRING,
VALFRDATE_CURRENT TYPE STRING,
BODID_FUTURE TYPE STRING,
VALFRDATE_FUTURE TYPE STRING,
PRD_STARTDT TYPE STRING,
PRD_ENDDT TYPE STRING,
NEWPROD_INDI TYPE STRING,
NEWMODEL_INDI TYPE STRING,
RECALL_STARTDT TYPE STRING,
RECALL_ENDDT TYPE STRING,
WTY_STARTDT TYPE STRING,
WTY_ENDDT TYPE STRING,
FLDFIX_STARTDT TYPE STRING,
FLDFIX_ENDDT TYPE STRING,
PROD_PAOOPT TYPE STRING,
ANALYST_REMARK TYPE STRING,
HAZMAT TYPE STRING,
PILFERABLE TYPE STRING,
LASTPO TYPE STRING,
OBSLTIND TYPE STRING,
NTGEW TYPE STRING,
GEWEI TYPE STRING,
LAENG TYPE STRING,
BREITE TYPE STRING,
HOEHE TYPE STRING,
MEABM TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
PRSTR TYPE STRING,
EOQTY TYPE STRING,
EOQDURA TYPE STRING,
EOQPODFIX TYPE STRING,
EOQRESCODE TYPE STRING,
COMMFRZINDI TYPE STRING,
SALESPRICE TYPE STRING,
MEINH TYPE STRING,
TPOP TYPE STRING,
LOCFR TYPE STRING,
LOCFROMTXT TYPE STRING,
SUPPLLDT TYPE STRING,
TGRPRT TYPE STRING,
THRUPUTTIME TYPE STRING,
GRPRT TYPE STRING,
PROM_STARTDT TYPE STRING,
PROM_ENDDT TYPE STRING,
AVGPRODPERBIN TYPE STRING,
RDYFROBSL TYPE STRING,
SRVBEN TYPE STRING,
DRPPLANMODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-BODID_CURR sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-VALFRDATE_CURRENT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-BODID_FUTURE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-VALFRDATE_FUTURE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PRD_STARTDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PRD_ENDDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-NEWPROD_INDI sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-NEWMODEL_INDI sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-RECALL_STARTDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-RECALL_ENDDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-WTY_STARTDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-WTY_ENDDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-FLDFIX_STARTDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-FLDFIX_ENDDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PROD_PAOOPT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-ANALYST_REMARK sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-HAZMAT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PILFERABLE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-LASTPO sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-OBSLTIND sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-NTGEW sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-GEWEI sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-LAENG sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-BREITE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-HOEHE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-MEABM sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-VOLUM sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-VOLEH sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PRSTR sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-EOQTY sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-EOQDURA sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-EOQPODFIX sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-EOQRESCODE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-COMMFRZINDI sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-SALESPRICE sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-MEINH sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-TPOP sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-LOCFR sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-LOCFROMTXT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-SUPPLLDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-TGRPRT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-THRUPUTTIME sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-GRPRT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PROM_STARTDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-PROM_ENDDT sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-AVGPRODPERBIN sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-RDYFROBSL sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-SRVBEN sy-vline
WA_/SAPAPO/PUIA_PD_PARTINFO_STR_STR-DRPPLANMODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.