ABAP Select data from SAP table /SAPF15/ELKOHKR5 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPF15/ELKOHKR5 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPF15/ELKOHKR5. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SAPF15/ELKOHKR5 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SAPF15/ELKOHKR5 TYPE STANDARD TABLE OF /SAPF15/ELKOHKR5, WA_/SAPF15/ELKOHKR5 TYPE /SAPF15/ELKOHKR5, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SAPF15/ELKOHKR5> TYPE /SAPF15/ELKOHKR5. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SAPF15/ELKOHKR5. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SAPF15/ELKOHKR5 INTO TABLE IT_/SAPF15/ELKOHKR5. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SAPF15/ELKOHKR5 * INTO TABLE @DATA(IT_/SAPF15/ELKOHKR52). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SAPF15/ELKOHKR5 INDEX 1 INTO DATA(WA_/SAPF15/ELKOHKR52). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SAPF15/ELKOHKR5 ASSIGNING </SAPF15/ELKOHKR5>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPF15/ELKOHKR5>-MANDT = 1.
</SAPF15/ELKOHKR5>-BUKRS = 1.
</SAPF15/ELKOHKR5>-GJAHR = 1.
</SAPF15/ELKOHKR5>-F03_N_BEWIRT = 1.
</SAPF15/ELKOHKR5>-F05_N_HHST = 1.
ENDLOOP. LOOP AT IT_/SAPF15/ELKOHKR5 INTO WA_/SAPF15/ELKOHKR5. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SAPF15/ELKOHKR5-F07_N_OBJNR, sy-vline,
WA_/SAPF15/ELKOHKR5-F15_N, sy-vline,
WA_/SAPF15/ELKOHKR5-F09_N, sy-vline,
WA_/SAPF15/ELKOHKR5-F11_N, sy-vline,
WA_/SAPF15/ELKOHKR5-F13_X, sy-vline,
WA_/SAPF15/ELKOHKR5-F17_N_BETRAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPF15/ELKOHKR5 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPF15/ELKOHKR5 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPF15/ELKOHKR5 INTO WA_/SAPF15/ELKOHKR5. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/SAPF15/ELKOHKR5-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SAPF15/ELKOHKR5-GJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPF15/ELKOHKR5_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
GJAHR TYPE STRING,
F03_N_BEWIRT TYPE STRING,
F05_N_HHST TYPE STRING,
F07_N_OBJNR TYPE STRING,
F15_N TYPE STRING,
F09_N TYPE STRING,
F11_N TYPE STRING,
F13_X TYPE STRING,
F17_N_BETRAG TYPE STRING,
F19_N_BETRAG TYPE STRING,
F21_N_BETRAG TYPE STRING,
F23_N_BETRAG TYPE STRING,
F25_N_BETRAG TYPE STRING,
F27_N_BETRAG TYPE STRING,
F29_N_BETRAG TYPE STRING,
F31_X TYPE STRING,
F33_N TYPE STRING,
F35_X TYPE STRING,
F37_X_TEXT TYPE STRING,
F39_N TYPE STRING,
F41_N TYPE STRING,
F43_N TYPE STRING,
F45_X TYPE STRING,
F47_N_GJAHR TYPE STRING,
F49_N TYPE STRING,
F51_N TYPE STRING,
STATUS TYPE STRING,
ERSDA TYPE STRING,
ERZET TYPE STRING,
ERNAM TYPE STRING,
USER_STATUS TYPE STRING,
USER_INFO TYPE STRING,
LOESCHKENNZEICHEN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPF15/ELKOHKR5_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPF15/ELKOHKR5_STR-MANDT sy-vline
WA_/SAPF15/ELKOHKR5_STR-BUKRS sy-vline
WA_/SAPF15/ELKOHKR5_STR-GJAHR sy-vline
WA_/SAPF15/ELKOHKR5_STR-F03_N_BEWIRT sy-vline
WA_/SAPF15/ELKOHKR5_STR-F05_N_HHST sy-vline
WA_/SAPF15/ELKOHKR5_STR-F07_N_OBJNR sy-vline
WA_/SAPF15/ELKOHKR5_STR-F15_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F09_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F11_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F13_X sy-vline
WA_/SAPF15/ELKOHKR5_STR-F17_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F19_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F21_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F23_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F25_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F27_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F29_N_BETRAG sy-vline
WA_/SAPF15/ELKOHKR5_STR-F31_X sy-vline
WA_/SAPF15/ELKOHKR5_STR-F33_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F35_X sy-vline
WA_/SAPF15/ELKOHKR5_STR-F37_X_TEXT sy-vline
WA_/SAPF15/ELKOHKR5_STR-F39_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F41_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F43_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F45_X sy-vline
WA_/SAPF15/ELKOHKR5_STR-F47_N_GJAHR sy-vline
WA_/SAPF15/ELKOHKR5_STR-F49_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-F51_N sy-vline
WA_/SAPF15/ELKOHKR5_STR-STATUS sy-vline
WA_/SAPF15/ELKOHKR5_STR-ERSDA sy-vline
WA_/SAPF15/ELKOHKR5_STR-ERZET sy-vline
WA_/SAPF15/ELKOHKR5_STR-ERNAM sy-vline
WA_/SAPF15/ELKOHKR5_STR-USER_STATUS sy-vline
WA_/SAPF15/ELKOHKR5_STR-USER_INFO sy-vline
WA_/SAPF15/ELKOHKR5_STR-LOESCHKENNZEICHEN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.