ABAP Select data from SAP table /SAPWF/HCMT_BSP_PA_UN_R0962_00 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPWF/HCMT_BSP_PA_UN_R0962_00 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPWF/HCMT_BSP_PA_UN_R0962_00. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SAPWF/HCMT_BSP_PA_UN_R0962_00 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SAPWF/HCMT_BSP_PA_UN_R0962_00 TYPE STANDARD TABLE OF /SAPWF/HCMT_BSP_PA_UN_R0962_00,
      WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00 TYPE /SAPWF/HCMT_BSP_PA_UN_R0962_00,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SAPWF/HCMT_BSP_PA_UN_R0962_00> TYPE /SAPWF/HCMT_BSP_PA_UN_R0962_00.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SAPWF/HCMT_BSP_PA_UN_R0962_00.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SAPWF/HCMT_BSP_PA_UN_R0962_00
  INTO TABLE IT_/SAPWF/HCMT_BSP_PA_UN_R0962_00.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SAPWF/HCMT_BSP_PA_UN_R0962_00
*  INTO TABLE @DATA(IT_/SAPWF/HCMT_BSP_PA_UN_R0962_002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SAPWF/HCMT_BSP_PA_UN_R0962_00 INDEX 1 INTO DATA(WA_/SAPWF/HCMT_BSP_PA_UN_R0962_002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SAPWF/HCMT_BSP_PA_UN_R0962_00 ASSIGNING </SAPWF/HCMT_BSP_PA_UN_R0962_00>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPWF/HCMT_BSP_PA_UN_R0962_00>-OBJECT_KEY = 1.
</SAPWF/HCMT_BSP_PA_UN_R0962_00>-PERNR = 1.
</SAPWF/HCMT_BSP_PA_UN_R0962_00>-AEDTM = 1.
</SAPWF/HCMT_BSP_PA_UN_R0962_00>-UNAME = 1.
</SAPWF/HCMT_BSP_PA_UN_R0962_00>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_/SAPWF/HCMT_BSP_PA_UN_R0962_00 INTO WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00-SPRTX, sy-vline,
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00-ITBLD, sy-vline,
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00-ITXEX, sy-vline,
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00-BEGDA, sy-vline,
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00-ENDDA, sy-vline,
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00-PREAS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPWF/HCMT_BSP_PA_UN_R0962_00 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPWF/HCMT_BSP_PA_UN_R0962_00 INTO WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PREAS TYPE STRING,
RSDRT TYPE STRING,
RSREA TYPE STRING,
LGART TYPE STRING,
LGTXT TYPE STRING,
OPKEN TYPE STRING,
BETRG TYPE STRING,
WAERS TYPE STRING,
RSAMT TYPE STRING,
WAAMT TYPE STRING,
RSBFA TYPE STRING,
WABFA TYPE STRING,
RSFMD TYPE STRING,
DSTAT TYPE STRING,
DSTXT TYPE STRING,
RSADT TYPE STRING,
RSLBD TYPE STRING,
RSLED TYPE STRING,
RSDEP TYPE STRING,
RSDAS TYPE STRING,
RSEIC TYPE STRING,
RSNBR TYPE STRING,
RSPCN TYPE STRING,
RSWAI TYPE STRING,
RSLLN TYPE STRING,
RSHNO TYPE STRING,
RSSTR TYPE STRING,
RSAPT TYPE STRING,
RSCTY TYPE STRING,
RSSTA TYPE STRING,
RSSTA_TEXT TYPE STRING,
RSCRY TYPE STRING,
RSPST TYPE STRING,
RSTEL TYPE STRING,
RSSCR TYPE STRING,
RSCOR TYPE STRING,
RSDRX TYPE STRING,
EMAIL TYPE STRING,
TEXT01 TYPE STRING,
TEXT02 TYPE STRING,
RSRAF TYPE STRING,
RSEXD TYPE STRING,
RSDSA TYPE STRING,
RSODP TYPE STRING,
RSBFD TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-OBJECT_KEY sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-PERNR sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-AEDTM sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-UNAME sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-SPRPS sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-SPRTX sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-ITBLD sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-ITXEX sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-BEGDA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-ENDDA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-PREAS sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSDRT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSREA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-LGART sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-LGTXT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-OPKEN sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-BETRG sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-WAERS sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSAMT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-WAAMT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSBFA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-WABFA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSFMD sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-DSTAT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-DSTXT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSADT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSLBD sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSLED sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSDEP sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSDAS sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSEIC sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSNBR sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSPCN sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSWAI sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSLLN sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSHNO sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSSTR sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSAPT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSCTY sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSSTA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSSTA_TEXT sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSCRY sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSPST sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSTEL sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSSCR sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSCOR sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSDRX sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-EMAIL sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-TEXT01 sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-TEXT02 sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSRAF sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSEXD sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSDSA sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSODP sy-vline
WA_/SAPWF/HCMT_BSP_PA_UN_R0962_00_STR-RSBFD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.