ABAP Select data from SAP table /SAPWF/SWF_TST_EXPSTR_______00 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SAPWF/SWF_TST_EXPSTR_______00 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SAPWF/SWF_TST_EXPSTR_______00. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SAPWF/SWF_TST_EXPSTR_______00 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SAPWF/SWF_TST_EXPSTR_______00 TYPE STANDARD TABLE OF /SAPWF/SWF_TST_EXPSTR_______00, WA_/SAPWF/SWF_TST_EXPSTR_______00 TYPE /SAPWF/SWF_TST_EXPSTR_______00, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SAPWF/SWF_TST_EXPSTR_______00> TYPE /SAPWF/SWF_TST_EXPSTR_______00. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SAPWF/SWF_TST_EXPSTR_______00. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SAPWF/SWF_TST_EXPSTR_______00 INTO TABLE IT_/SAPWF/SWF_TST_EXPSTR_______00. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SAPWF/SWF_TST_EXPSTR_______00 * INTO TABLE @DATA(IT_/SAPWF/SWF_TST_EXPSTR_______002). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SAPWF/SWF_TST_EXPSTR_______00 INDEX 1 INTO DATA(WA_/SAPWF/SWF_TST_EXPSTR_______002). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SAPWF/SWF_TST_EXPSTR_______00 ASSIGNING </SAPWF/SWF_TST_EXPSTR_______00>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SAPWF/SWF_TST_EXPSTR_______00>-ACCP = 1.
</SAPWF/SWF_TST_EXPSTR_______00>-CHAR10 = 1.
</SAPWF/SWF_TST_EXPSTR_______00>-CHAR50 = 1.
</SAPWF/SWF_TST_EXPSTR_______00>-DATS = 1.
</SAPWF/SWF_TST_EXPSTR_______00>-DEC = 1.
ENDLOOP. LOOP AT IT_/SAPWF/SWF_TST_EXPSTR_______00 INTO WA_/SAPWF/SWF_TST_EXPSTR_______00. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SAPWF/SWF_TST_EXPSTR_______00-FLTP, sy-vline,
WA_/SAPWF/SWF_TST_EXPSTR_______00-INT1, sy-vline,
WA_/SAPWF/SWF_TST_EXPSTR_______00-INT2, sy-vline,
WA_/SAPWF/SWF_TST_EXPSTR_______00-INT4, sy-vline,
WA_/SAPWF/SWF_TST_EXPSTR_______00-NUMC1, sy-vline,
WA_/SAPWF/SWF_TST_EXPSTR_______00-NUMC10, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SAPWF/SWF_TST_EXPSTR_______00 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SAPWF/SWF_TST_EXPSTR_______00 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SAPWF/SWF_TST_EXPSTR_______00 INTO WA_/SAPWF/SWF_TST_EXPSTR_______00. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SAPWF/SWF_TST_EXPSTR_______00_STR,
ACCP TYPE STRING,
CHAR10 TYPE STRING,
CHAR50 TYPE STRING,
DATS TYPE STRING,
DEC TYPE STRING,
FLTP TYPE STRING,
INT1 TYPE STRING,
INT2 TYPE STRING,
INT4 TYPE STRING,
NUMC1 TYPE STRING,
NUMC10 TYPE STRING,
STRING TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SAPWF/SWF_TST_EXPSTR_______00_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-ACCP sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-CHAR10 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-CHAR50 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-DATS sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-DEC sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-FLTP sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-INT1 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-INT2 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-INT4 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-NUMC1 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-NUMC10 sy-vline
WA_/SAPWF/SWF_TST_EXPSTR_______00_STR-STRING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.