ABAP Select data from SAP table /SCF/QP_LOCPRODPRT_STR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCF/QP_LOCPRODPRT_STR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCF/QP_LOCPRODPRT_STR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCF/QP_LOCPRODPRT_STR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCF/QP_LOCPRODPRT_STR TYPE STANDARD TABLE OF /SCF/QP_LOCPRODPRT_STR,
      WA_/SCF/QP_LOCPRODPRT_STR TYPE /SCF/QP_LOCPRODPRT_STR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCF/QP_LOCPRODPRT_STR> TYPE /SCF/QP_LOCPRODPRT_STR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCF/QP_LOCPRODPRT_STR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCF/QP_LOCPRODPRT_STR
  INTO TABLE IT_/SCF/QP_LOCPRODPRT_STR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCF/QP_LOCPRODPRT_STR
*  INTO TABLE @DATA(IT_/SCF/QP_LOCPRODPRT_STR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCF/QP_LOCPRODPRT_STR INDEX 1 INTO DATA(WA_/SCF/QP_LOCPRODPRT_STR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCF/QP_LOCPRODPRT_STR ASSIGNING </SCF/QP_LOCPRODPRT_STR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCF/QP_LOCPRODPRT_STR>-OBJ_GUID = 1.
</SCF/QP_LOCPRODPRT_STR>-LOCID = 1.
</SCF/QP_LOCPRODPRT_STR>-MATID = 1.
</SCF/QP_LOCPRODPRT_STR>-PARTNER_GUID = 1.
</SCF/QP_LOCPRODPRT_STR>-LOCNOTO = 1.
ENDLOOP.

LOOP AT IT_/SCF/QP_LOCPRODPRT_STR INTO WA_/SCF/QP_LOCPRODPRT_STR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCF/QP_LOCPRODPRT_STR-PRTLOCNO, sy-vline,
WA_/SCF/QP_LOCPRODPRT_STR-MATNR, sy-vline,
WA_/SCF/QP_LOCPRODPRT_STR-PRTMATNR, sy-vline,
WA_/SCF/QP_LOCPRODPRT_STR-PARTNERNO_FROM, sy-vline,
WA_/SCF/QP_LOCPRODPRT_STR-MINSTOCK, sy-vline,
WA_/SCF/QP_LOCPRODPRT_STR-REORDERPOINT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCF/QP_LOCPRODPRT_STR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCF/QP_LOCPRODPRT_STR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCF/QP_LOCPRODPRT_STR INTO WA_/SCF/QP_LOCPRODPRT_STR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PARTNERNO_FROM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCF/QP_LOCPRODPRT_STR-PARTNERNO_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCF/QP_LOCPRODPRT_STR-PARTNERNO_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field MINDURATION CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_/SCF/QP_LOCPRODPRT_STR-MINDURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCF/QP_LOCPRODPRT_STR-MINDURATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field MAXDURATION CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_/SCF/QP_LOCPRODPRT_STR-MAXDURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCF/QP_LOCPRODPRT_STR-MAXDURATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCF/QP_LOCPRODPRT_STR-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCF/QP_LOCPRODPRT_STR-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LSUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCF/QP_LOCPRODPRT_STR-LSUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCF/QP_LOCPRODPRT_STR-LSUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCF/QP_LOCPRODPRT_STR_STR,
OBJ_GUID TYPE STRING,
LOCID TYPE STRING,
MATID TYPE STRING,
PARTNER_GUID TYPE STRING,
LOCNOTO TYPE STRING,
PRTLOCNO TYPE STRING,
MATNR TYPE STRING,
PRTMATNR TYPE STRING,
PARTNERNO_FROM TYPE STRING,
MINSTOCK TYPE STRING,
REORDERPOINT TYPE STRING,
MAXSTOCK TYPE STRING,
USEDURATION TYPE STRING,
MINDURATION TYPE STRING,
MAXDURATION TYPE STRING,
LOCPRODROUNDING TYPE STRING,
CSCC TYPE STRING,
UNIT TYPE STRING,
LSUOM TYPE STRING,
ASPECTREF_KEY TYPE STRING,
ASPECTREF_DATA TYPE STRING,
OBJCHG TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCF/QP_LOCPRODPRT_STR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-OBJ_GUID sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-LOCID sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-MATID sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-PARTNER_GUID sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-LOCNOTO sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-PRTLOCNO sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-MATNR sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-PRTMATNR sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-PARTNERNO_FROM sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-MINSTOCK sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-REORDERPOINT sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-MAXSTOCK sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-USEDURATION sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-MINDURATION sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-MAXDURATION sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-LOCPRODROUNDING sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-CSCC sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-UNIT sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-LSUOM sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-ASPECTREF_KEY sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-ASPECTREF_DATA sy-vline
WA_/SCF/QP_LOCPRODPRT_STR_STR-OBJCHG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.