ABAP Select data from SAP table /SCMTMS/D_PLNXLA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/D_PLNXLA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/D_PLNXLA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/D_PLNXLA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/D_PLNXLA TYPE STANDARD TABLE OF /SCMTMS/D_PLNXLA,
      WA_/SCMTMS/D_PLNXLA TYPE /SCMTMS/D_PLNXLA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/D_PLNXLA> TYPE /SCMTMS/D_PLNXLA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/D_PLNXLA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/D_PLNXLA
  INTO TABLE IT_/SCMTMS/D_PLNXLA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/D_PLNXLA
*  INTO TABLE @DATA(IT_/SCMTMS/D_PLNXLA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/D_PLNXLA INDEX 1 INTO DATA(WA_/SCMTMS/D_PLNXLA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/D_PLNXLA ASSIGNING </SCMTMS/D_PLNXLA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/D_PLNXLA>-MANDT = 1.
</SCMTMS/D_PLNXLA>-DB_KEY = 1.
</SCMTMS/D_PLNXLA>-PARENT_KEY = 1.
</SCMTMS/D_PLNXLA>-LANE_ID = 1.
</SCMTMS/D_PLNXLA>-MTR = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/D_PLNXLA INTO WA_/SCMTMS/D_PLNXLA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/D_PLNXLA-LOC_FROM, sy-vline,
WA_/SCMTMS/D_PLNXLA-LOC_TO, sy-vline,
WA_/SCMTMS/D_PLNXLA-LANE_GUID, sy-vline,
WA_/SCMTMS/D_PLNXLA-DIST_ID, sy-vline,
WA_/SCMTMS/D_PLNXLA-DURATION, sy-vline,
WA_/SCMTMS/D_PLNXLA-DISTANCE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/D_PLNXLA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/D_PLNXLA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/D_PLNXLA INTO WA_/SCMTMS/D_PLNXLA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXP01, internal->external for field LOC_FROM CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-LOC_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-LOC_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field LOC_TO CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-LOC_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-LOC_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field LANE_GUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-LANE_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-LANE_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field DISTANCE CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-DISTANCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-DISTANCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field LANECOST_FIX CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-LANECOST_FIX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-LANECOST_FIX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field LANECOST_P_DIST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-LANECOST_P_DIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-LANECOST_P_DIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field LANECOST_P_DUR CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-LANECOST_P_DUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-LANECOST_P_DUR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field UNITCOST_FIX CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-UNITCOST_FIX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-UNITCOST_FIX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field UNITCOST_P_DIST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-UNITCOST_P_DIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-UNITCOST_P_DIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field UNITCOST_P_DUR CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-UNITCOST_P_DUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-UNITCOST_P_DUR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field DEST_BASED_DISTCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-DEST_BASED_DISTCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-DEST_BASED_DISTCOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field MIN_DEST_BASED_DISTCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/D_PLNXLA-MIN_DEST_BASED_DISTCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_PLNXLA-MIN_DEST_BASED_DISTCOST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/D_PLNXLA_STR,
MANDT TYPE STRING,
DB_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
LANE_ID TYPE STRING,
MTR TYPE STRING,
LOC_FROM TYPE STRING,
LOC_TO TYPE STRING,
LANE_GUID TYPE STRING,
DIST_ID TYPE STRING,
DURATION TYPE STRING,
DISTANCE TYPE STRING,
LANECOST_FIX TYPE STRING,
LANECOST_P_DIST TYPE STRING,
LANECOST_P_DUR TYPE STRING,
UNITCOST_FIX TYPE STRING,
UNITCOST_P_DIST TYPE STRING,
UNITCOST_P_DUR TYPE STRING,
DETERM_PRIO TYPE STRING,
DEST_BASED_DISTCOST TYPE STRING,
MIN_DEST_BASED_DISTCOST TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/D_PLNXLA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/D_PLNXLA_STR-MANDT sy-vline
WA_/SCMTMS/D_PLNXLA_STR-DB_KEY sy-vline
WA_/SCMTMS/D_PLNXLA_STR-PARENT_KEY sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LANE_ID sy-vline
WA_/SCMTMS/D_PLNXLA_STR-MTR sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LOC_FROM sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LOC_TO sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LANE_GUID sy-vline
WA_/SCMTMS/D_PLNXLA_STR-DIST_ID sy-vline
WA_/SCMTMS/D_PLNXLA_STR-DURATION sy-vline
WA_/SCMTMS/D_PLNXLA_STR-DISTANCE sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LANECOST_FIX sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LANECOST_P_DIST sy-vline
WA_/SCMTMS/D_PLNXLA_STR-LANECOST_P_DUR sy-vline
WA_/SCMTMS/D_PLNXLA_STR-UNITCOST_FIX sy-vline
WA_/SCMTMS/D_PLNXLA_STR-UNITCOST_P_DIST sy-vline
WA_/SCMTMS/D_PLNXLA_STR-UNITCOST_P_DUR sy-vline
WA_/SCMTMS/D_PLNXLA_STR-DETERM_PRIO sy-vline
WA_/SCMTMS/D_PLNXLA_STR-DEST_BASED_DISTCOST sy-vline
WA_/SCMTMS/D_PLNXLA_STR-MIN_DEST_BASED_DISTCOST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.