ABAP Select data from SAP table /SCMTMS/D_TCRT1D into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/D_TCRT1D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/D_TCRT1D. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCMTMS/D_TCRT1D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCMTMS/D_TCRT1D TYPE STANDARD TABLE OF /SCMTMS/D_TCRT1D, WA_/SCMTMS/D_TCRT1D TYPE /SCMTMS/D_TCRT1D, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCMTMS/D_TCRT1D> TYPE /SCMTMS/D_TCRT1D. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/D_TCRT1D. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCMTMS/D_TCRT1D INTO TABLE IT_/SCMTMS/D_TCRT1D. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCMTMS/D_TCRT1D * INTO TABLE @DATA(IT_/SCMTMS/D_TCRT1D2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCMTMS/D_TCRT1D INDEX 1 INTO DATA(WA_/SCMTMS/D_TCRT1D2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCMTMS/D_TCRT1D ASSIGNING </SCMTMS/D_TCRT1D>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/D_TCRT1D>-MANDT = 1.
</SCMTMS/D_TCRT1D>-DB_KEY = 1.
</SCMTMS/D_TCRT1D>-PARENT_KEY = 1.
</SCMTMS/D_TCRT1D>-ROOT_KEY = 1.
</SCMTMS/D_TCRT1D>-SCALE_ITEM_KEY01 = 1.
ENDLOOP. LOOP AT IT_/SCMTMS/D_TCRT1D INTO WA_/SCMTMS/D_TCRT1D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCMTMS/D_TCRT1D-RATE, sy-vline,
WA_/SCMTMS/D_TCRT1D-RATE_CURR, sy-vline,
WA_/SCMTMS/D_TCRT1D-TARGET_RATE, sy-vline,
WA_/SCMTMS/D_TCRT1D-TOLERANCE, sy-vline,
WA_/SCMTMS/D_TCRT1D-ZERO_RATE, sy-vline,
WA_/SCMTMS/D_TCRT1D-SOL_SPEND_AMOUNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/D_TCRT1D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/D_TCRT1D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/D_TCRT1D INTO WA_/SCMTMS/D_TCRT1D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_TCRT1D-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_TCRT1D-CREATED_ON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/D_TCRT1D-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/D_TCRT1D-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/D_TCRT1D_STR,
MANDT TYPE STRING,
DB_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
SCALE_ITEM_KEY01 TYPE STRING,
RATE TYPE STRING,
RATE_CURR TYPE STRING,
TARGET_RATE TYPE STRING,
TOLERANCE TYPE STRING,
ZERO_RATE TYPE STRING,
SOL_SPEND_AMOUNT TYPE STRING,
SOL_SPEND_CURR TYPE STRING,
RATE_REQUESTED TYPE STRING,
VALID_START_DT TYPE STRING,
VALID_END_DT TYPE STRING,
RATE_DATE_FROM_TS TYPE STRING,
RATE_DATE_TO_TS TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
EEW_TCRATE_1DMRT TYPE STRING,
_DATAAGING TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/D_TCRT1D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/D_TCRT1D_STR-MANDT sy-vline
WA_/SCMTMS/D_TCRT1D_STR-DB_KEY sy-vline
WA_/SCMTMS/D_TCRT1D_STR-PARENT_KEY sy-vline
WA_/SCMTMS/D_TCRT1D_STR-ROOT_KEY sy-vline
WA_/SCMTMS/D_TCRT1D_STR-SCALE_ITEM_KEY01 sy-vline
WA_/SCMTMS/D_TCRT1D_STR-RATE sy-vline
WA_/SCMTMS/D_TCRT1D_STR-RATE_CURR sy-vline
WA_/SCMTMS/D_TCRT1D_STR-TARGET_RATE sy-vline
WA_/SCMTMS/D_TCRT1D_STR-TOLERANCE sy-vline
WA_/SCMTMS/D_TCRT1D_STR-ZERO_RATE sy-vline
WA_/SCMTMS/D_TCRT1D_STR-SOL_SPEND_AMOUNT sy-vline
WA_/SCMTMS/D_TCRT1D_STR-SOL_SPEND_CURR sy-vline
WA_/SCMTMS/D_TCRT1D_STR-RATE_REQUESTED sy-vline
WA_/SCMTMS/D_TCRT1D_STR-VALID_START_DT sy-vline
WA_/SCMTMS/D_TCRT1D_STR-VALID_END_DT sy-vline
WA_/SCMTMS/D_TCRT1D_STR-RATE_DATE_FROM_TS sy-vline
WA_/SCMTMS/D_TCRT1D_STR-RATE_DATE_TO_TS sy-vline
WA_/SCMTMS/D_TCRT1D_STR-CREATED_BY sy-vline
WA_/SCMTMS/D_TCRT1D_STR-CREATED_ON sy-vline
WA_/SCMTMS/D_TCRT1D_STR-CHANGED_BY sy-vline
WA_/SCMTMS/D_TCRT1D_STR-CHANGED_ON sy-vline
WA_/SCMTMS/D_TCRT1D_STR-EEW_TCRATE_1DMRT sy-vline
WA_/SCMTMS/D_TCRT1D_STR-_DATAAGING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.