ABAP Select data from SAP table /SCMTMS/EXTR_STR_CFIR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/EXTR_STR_CFIR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/EXTR_STR_CFIR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/EXTR_STR_CFIR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/EXTR_STR_CFIR TYPE STANDARD TABLE OF /SCMTMS/EXTR_STR_CFIR,
      WA_/SCMTMS/EXTR_STR_CFIR TYPE /SCMTMS/EXTR_STR_CFIR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/EXTR_STR_CFIR> TYPE /SCMTMS/EXTR_STR_CFIR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/EXTR_STR_CFIR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/EXTR_STR_CFIR
  INTO TABLE IT_/SCMTMS/EXTR_STR_CFIR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/EXTR_STR_CFIR
*  INTO TABLE @DATA(IT_/SCMTMS/EXTR_STR_CFIR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/EXTR_STR_CFIR INDEX 1 INTO DATA(WA_/SCMTMS/EXTR_STR_CFIR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/EXTR_STR_CFIR ASSIGNING </SCMTMS/EXTR_STR_CFIR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/EXTR_STR_CFIR>-CFIR_DBK = 1.
</SCMTMS/EXTR_STR_CFIR>-CFIR_ID = 1.
</SCMTMS/EXTR_STR_CFIR>-CFIR_TYPE = 1.
</SCMTMS/EXTR_STR_CFIR>-CFIR_CAT = 1.
</SCMTMS/EXTR_STR_CFIR>-SALES_ORG_EXTID = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/EXTR_STR_CFIR INTO WA_/SCMTMS/EXTR_STR_CFIR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/EXTR_STR_CFIR-SALES_OFF_EXTID, sy-vline,
WA_/SCMTMS/EXTR_STR_CFIR-SALES_GRP_EXTID, sy-vline,
WA_/SCMTMS/EXTR_STR_CFIR-FWSD_CLASS, sy-vline,
WA_/SCMTMS/EXTR_STR_CFIR-CM_REASON, sy-vline,
WA_/SCMTMS/EXTR_STR_CFIR-GRO_WEI_VAL, sy-vline,
WA_/SCMTMS/EXTR_STR_CFIR-GRO_WEI_UNI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/EXTR_STR_CFIR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/EXTR_STR_CFIR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/EXTR_STR_CFIR INTO WA_/SCMTMS/EXTR_STR_CFIR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CFIR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CFIR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CFIR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NET_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-NET_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-NET_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-NET_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-NET_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field BASE_UOM_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-BASE_UOM_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-BASE_UOM_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-BASE_UOM_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-BASE_UOM_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field PKGUN_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-PKGUN_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-PKGUN_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-PKGUN_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-PKGUN_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field DG_ADR_PTS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-DG_ADR_PTS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-DG_ADR_PTS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DG_ADR_PTS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-DG_ADR_PTS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-DG_ADR_PTS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CNF_CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CNF_CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/EXTR_STR_CFIR-CNF_CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/EXTR_STR_CFIR-CNF_CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/EXTR_STR_CFIR_STR,
CFIR_DBK TYPE STRING,
CFIR_ID TYPE STRING,
CFIR_TYPE TYPE STRING,
CFIR_CAT TYPE STRING,
SALES_ORG_EXTID TYPE STRING,
SALES_OFF_EXTID TYPE STRING,
SALES_GRP_EXTID TYPE STRING,
FWSD_CLASS TYPE STRING,
CM_REASON TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
NET_WEI_VAL TYPE STRING,
NET_WEI_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
QUA_PCS2_VAL TYPE STRING,
QUA_PCS2_UNI TYPE STRING,
BASE_UOM_VAL TYPE STRING,
BASE_UOM_UNI TYPE STRING,
PKGUN_WEI_VAL TYPE STRING,
PKGUN_WEI_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DG_ADR_PTS_VAL TYPE STRING,
DG_ADR_PTS_UNI TYPE STRING,
CNF_GRO_WEI_VAL TYPE STRING,
CNF_GRO_WEI_UNI TYPE STRING,
CNF_GRO_VOL_VAL TYPE STRING,
CNF_GRO_VOL_UNI TYPE STRING,
CNF_QUA_PCS_VAL TYPE STRING,
CNF_QUA_PCS_UNI TYPE STRING,
CNF_QUA_PCS2_VAL TYPE STRING,
CNF_QUA_PCS2_UNI TYPE STRING,
CNF_CONT_CNT_VAL TYPE STRING,
CNF_CONT_CNT_UNI TYPE STRING,
AMT_GDSV_VAL TYPE STRING,
AMT_GDSV_CUR TYPE STRING,
AMT_INSV_VAL TYPE STRING,
AMT_INSV_CUR TYPE STRING,
AMT_GDSVC_VAL TYPE STRING,
AMT_GDSVC_CUR TYPE STRING,
AMT_HVAL_CAR_IND TYPE STRING,
AMT_GDSV_VAL_2 TYPE STRING,
AMT_INSV_VAL_2 TYPE STRING,
AMT_GDSVC_VAL_2 TYPE STRING,
CREATION_TSTMP TYPE STRING,
CREATION_DATE TYPE STRING,
CREATED_BY TYPE STRING,
CHANGE_TSTMP TYPE STRING,
CHANGE_DATE TYPE STRING,
CHANGED_BY TYPE STRING,
INVOICE_DATE TYPE STRING,
LIFECYCLE TYPE STRING,
ROCANCEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/EXTR_STR_CFIR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CFIR_DBK sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CFIR_ID sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CFIR_TYPE sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CFIR_CAT sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-SALES_ORG_EXTID sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-SALES_OFF_EXTID sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-SALES_GRP_EXTID sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-FWSD_CLASS sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CM_REASON sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-NET_WEI_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-NET_WEI_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-QUA_PCS2_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-QUA_PCS2_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-BASE_UOM_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-BASE_UOM_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-PKGUN_WEI_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-PKGUN_WEI_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-DG_ADR_PTS_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-DG_ADR_PTS_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_GRO_WEI_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_GRO_WEI_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_GRO_VOL_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_GRO_VOL_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_QUA_PCS_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_QUA_PCS_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_QUA_PCS2_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_QUA_PCS2_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_CONT_CNT_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CNF_CONT_CNT_UNI sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_GDSV_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_GDSV_CUR sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_INSV_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_INSV_CUR sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_GDSVC_VAL sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_GDSVC_CUR sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_HVAL_CAR_IND sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_GDSV_VAL_2 sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_INSV_VAL_2 sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-AMT_GDSVC_VAL_2 sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CREATION_TSTMP sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CREATION_DATE sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CREATED_BY sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CHANGE_TSTMP sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CHANGE_DATE sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-CHANGED_BY sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-INVOICE_DATE sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-LIFECYCLE sy-vline
WA_/SCMTMS/EXTR_STR_CFIR_STR-ROCANCEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.