ABAP Select data from SAP table /SCMTMS/S_DG_INFO_CORE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_DG_INFO_CORE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_DG_INFO_CORE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_DG_INFO_CORE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_DG_INFO_CORE TYPE STANDARD TABLE OF /SCMTMS/S_DG_INFO_CORE,
      WA_/SCMTMS/S_DG_INFO_CORE TYPE /SCMTMS/S_DG_INFO_CORE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_DG_INFO_CORE> TYPE /SCMTMS/S_DG_INFO_CORE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_DG_INFO_CORE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_DG_INFO_CORE
  INTO TABLE IT_/SCMTMS/S_DG_INFO_CORE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_DG_INFO_CORE
*  INTO TABLE @DATA(IT_/SCMTMS/S_DG_INFO_CORE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_DG_INFO_CORE INDEX 1 INTO DATA(WA_/SCMTMS/S_DG_INFO_CORE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_DG_INFO_CORE ASSIGNING </SCMTMS/S_DG_INFO_CORE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_DG_INFO_CORE>-LWDG_ORD = 1.
</SCMTMS/S_DG_INFO_CORE>-LWDG = 1.
</SCMTMS/S_DG_INFO_CORE>-EMSN1 = 1.
</SCMTMS/S_DG_INFO_CORE>-EMSN2 = 1.
</SCMTMS/S_DG_INFO_CORE>-FLG_EMSN1_U = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_DG_INFO_CORE INTO WA_/SCMTMS/S_DG_INFO_CORE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_DG_INFO_CORE-FLG_EMSN2_U, sy-vline,
WA_/SCMTMS/S_DG_INFO_CORE-PRES1, sy-vline,
WA_/SCMTMS/S_DG_INFO_CORE-PRES2, sy-vline,
WA_/SCMTMS/S_DG_INFO_CORE-PRES3, sy-vline,
WA_/SCMTMS/S_DG_INFO_CORE-DGTNA, sy-vline,
WA_/SCMTMS/S_DG_INFO_CORE-PASI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_DG_INFO_CORE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_DG_INFO_CORE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_DG_INFO_CORE INTO WA_/SCMTMS/S_DG_INFO_CORE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UPASI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_DG_INFO_CORE-UPASI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_DG_INFO_CORE-UPASI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FLASHPOINT_TEMP_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_DG_INFO_CORE-FLASHPOINT_TEMP_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_DG_INFO_CORE-FLASHPOINT_TEMP_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_DG_INFO_CORE_STR,
LWDG_ORD TYPE STRING,
LWDG TYPE STRING,
EMSN1 TYPE STRING,
EMSN2 TYPE STRING,
FLG_EMSN1_U TYPE STRING,
FLG_EMSN2_U TYPE STRING,
PRES1 TYPE STRING,
PRES2 TYPE STRING,
PRES3 TYPE STRING,
DGTNA TYPE STRING,
PASI TYPE STRING,
UPASI TYPE STRING,
DGMOT TYPE STRING,
CLASS TYPE STRING,
ID_NUMBER_TYPE TYPE STRING,
ID_NUMBER TYPE STRING,
SUBCLASS TYPE STRING,
HAZARD_CODE TYPE STRING,
PACK_GROUP TYPE STRING,
FLASHPOINT_TEMP TYPE STRING,
FLASHPOINT_TEMP_UNIT TYPE STRING,
TREMCARD_NUMBER TYPE STRING,
PROPER_SHIPPING_NAME TYPE STRING,
TRANSP_MEANS_CAT_CODE TYPE STRING,
PACKAGING_INST_CODE TYPE STRING,
DG_LABEL_CODE_01 TYPE STRING,
DG_LABEL_CODE_02 TYPE STRING,
DG_LABEL_CODE_03 TYPE STRING,
DG_LABEL_CODE_04 TYPE STRING,
DG_LABEL_CODE_05 TYPE STRING,
DG_LABEL_CODE_06 TYPE STRING,
DG_LABEL_CODE_07 TYPE STRING,
TUNNEL_CODE TYPE STRING,
AIR_CARGO_ONLY TYPE STRING,
HAZARD_IND_SUBST_1 TYPE STRING,
HAZARD_IND_SUBST_2 TYPE STRING,
DG_DESCRIPTION TYPE STRING,
WATER_POLL_CLASS TYPE STRING,
TRANSPORT_CATEGORY TYPE STRING,
VARIANT_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_DG_INFO_CORE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-LWDG_ORD sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-LWDG sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-EMSN1 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-EMSN2 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-FLG_EMSN1_U sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-FLG_EMSN2_U sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PRES1 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PRES2 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PRES3 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DGTNA sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PASI sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-UPASI sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DGMOT sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-CLASS sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-ID_NUMBER_TYPE sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-ID_NUMBER sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-SUBCLASS sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-HAZARD_CODE sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PACK_GROUP sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-FLASHPOINT_TEMP sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-FLASHPOINT_TEMP_UNIT sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-TREMCARD_NUMBER sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PROPER_SHIPPING_NAME sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-TRANSP_MEANS_CAT_CODE sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-PACKAGING_INST_CODE sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_01 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_02 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_03 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_04 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_05 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_06 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_LABEL_CODE_07 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-TUNNEL_CODE sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-AIR_CARGO_ONLY sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-HAZARD_IND_SUBST_1 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-HAZARD_IND_SUBST_2 sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-DG_DESCRIPTION sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-WATER_POLL_CLASS sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-TRANSPORT_CATEGORY sy-vline
WA_/SCMTMS/S_DG_INFO_CORE_STR-VARIANT_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.