ABAP Select data from SAP table /SCMTMS/S_GW_EV_NOT_FO_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_GW_EV_NOT_FO_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_GW_EV_NOT_FO_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_GW_EV_NOT_FO_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_GW_EV_NOT_FO_DATA TYPE STANDARD TABLE OF /SCMTMS/S_GW_EV_NOT_FO_DATA,
      WA_/SCMTMS/S_GW_EV_NOT_FO_DATA TYPE /SCMTMS/S_GW_EV_NOT_FO_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_GW_EV_NOT_FO_DATA> TYPE /SCMTMS/S_GW_EV_NOT_FO_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_GW_EV_NOT_FO_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_GW_EV_NOT_FO_DATA
  INTO TABLE IT_/SCMTMS/S_GW_EV_NOT_FO_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_GW_EV_NOT_FO_DATA
*  INTO TABLE @DATA(IT_/SCMTMS/S_GW_EV_NOT_FO_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_GW_EV_NOT_FO_DATA INDEX 1 INTO DATA(WA_/SCMTMS/S_GW_EV_NOT_FO_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_GW_EV_NOT_FO_DATA ASSIGNING </SCMTMS/S_GW_EV_NOT_FO_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_GW_EV_NOT_FO_DATA>-FOR_STATUS_CODE = 1.
</SCMTMS/S_GW_EV_NOT_FO_DATA>-FOR_STATUS_DESCR = 1.
</SCMTMS/S_GW_EV_NOT_FO_DATA>-NEXT_OP_EV_CODE = 1.
</SCMTMS/S_GW_EV_NOT_FO_DATA>-NEXT_OP_EV_DESCR = 1.
</SCMTMS/S_GW_EV_NOT_FO_DATA>-NEXT_OP_EV_LOC_DESCR = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_GW_EV_NOT_FO_DATA INTO WA_/SCMTMS/S_GW_EV_NOT_FO_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-NEXT_OP_EV_DT, sy-vline,
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-NEXT_OP_EV_TZ, sy-vline,
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-NEXT_OP_EV_STOP_UUID, sy-vline,
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-NEXT_OP_EV_STATUS_CODE, sy-vline,
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-LAST_EXP_EV_CD, sy-vline,
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-START_DT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_GW_EV_NOT_FO_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_GW_EV_NOT_FO_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_GW_EV_NOT_FO_DATA INTO WA_/SCMTMS/S_GW_EV_NOT_FO_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTRN, internal->external for field TOTAL_DURATION CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-TOTAL_DURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-TOTAL_DURATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NR_ALL_LOC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-NR_ALL_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-NR_ALL_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TOR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-TOR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-TOR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TOTAL_DISTANCE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-TOTAL_DISTANCE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_GW_EV_NOT_FO_DATA-TOTAL_DISTANCE_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR,
FOR_STATUS_CODE TYPE STRING,
FOR_STATUS_DESCR TYPE STRING,
NEXT_OP_EV_CODE TYPE STRING,
NEXT_OP_EV_DESCR TYPE STRING,
NEXT_OP_EV_LOC_DESCR TYPE STRING,
NEXT_OP_EV_DT TYPE STRING,
NEXT_OP_EV_TZ TYPE STRING,
NEXT_OP_EV_STOP_UUID TYPE STRING,
NEXT_OP_EV_STATUS_CODE TYPE STRING,
LAST_EXP_EV_CD TYPE STRING,
START_DT TYPE STRING,
START_DT_UTC TYPE STRING,
MTR TYPE STRING,
DANGEROUS_GOODS_IND TYPE STRING,
TOTAL_DURATION TYPE STRING,
NR_ALL_LOC TYPE STRING,
SERVICE_LEVEL_CODE TYPE STRING,
SERVICE_LEVEL_CODE_DESC TYPE STRING,
FOR_TYPE_CODE TYPE STRING,
TOR_ID TYPE STRING,
USER_LOCAL_TIME_ZONE TYPE STRING,
SOURCE_LOC_DESCR TYPE STRING,
SOURCE_LOC_COUNTRY_CODE TYPE STRING,
SOURCE_LOC_REGION TYPE STRING,
SOURCE_LOC_CITY_NAME TYPE STRING,
SOURCE_LOC_STREET_POSTAL_CODE TYPE STRING,
SOURCE_LOC_STREET_NAME TYPE STRING,
SOURCE_LOC_FORMATTED TYPE STRING,
SOURCE_LOC_TIME_ZONE TYPE STRING,
DEST_LOC_DESCR TYPE STRING,
DEST_LOC_COUNTRY_CODE TYPE STRING,
DEST_LOC_REGION TYPE STRING,
DEST_LOC_CITY_NAME TYPE STRING,
DEST_LOC_STREET_POSTAL_CODE TYPE STRING,
DEST_LOC_STREET_NAME TYPE STRING,
DEST_LOC_FORMATTED TYPE STRING,
DEST_LOC_TIME_ZONE TYPE STRING,
TOTAL_DISTANCE TYPE STRING,
TOTAL_DISTANCE_UOM TYPE STRING,
SHIPPER_NAME TYPE STRING,
CONSIGNEE_PTY_TITLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-FOR_STATUS_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-FOR_STATUS_DESCR sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_DESCR sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_LOC_DESCR sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_DT sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_TZ sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_STOP_UUID sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NEXT_OP_EV_STATUS_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-LAST_EXP_EV_CD sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-START_DT sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-START_DT_UTC sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-MTR sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DANGEROUS_GOODS_IND sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-TOTAL_DURATION sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-NR_ALL_LOC sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SERVICE_LEVEL_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SERVICE_LEVEL_CODE_DESC sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-FOR_TYPE_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-TOR_ID sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-USER_LOCAL_TIME_ZONE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_DESCR sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_COUNTRY_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_REGION sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_CITY_NAME sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_STREET_POSTAL_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_STREET_NAME sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_FORMATTED sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SOURCE_LOC_TIME_ZONE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_DESCR sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_COUNTRY_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_REGION sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_CITY_NAME sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_STREET_POSTAL_CODE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_STREET_NAME sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_FORMATTED sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-DEST_LOC_TIME_ZONE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-TOTAL_DISTANCE sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-TOTAL_DISTANCE_UOM sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-SHIPPER_NAME sy-vline
WA_/SCMTMS/S_GW_EV_NOT_FO_DATA_STR-CONSIGNEE_PTY_TITLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.