ABAP Select data from SAP table /SCMTMS/S_PLN_EX_RES_FOR_ST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_PLN_EX_RES_FOR_ST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_PLN_EX_RES_FOR_ST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCMTMS/S_PLN_EX_RES_FOR_ST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCMTMS/S_PLN_EX_RES_FOR_ST TYPE STANDARD TABLE OF /SCMTMS/S_PLN_EX_RES_FOR_ST, WA_/SCMTMS/S_PLN_EX_RES_FOR_ST TYPE /SCMTMS/S_PLN_EX_RES_FOR_ST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCMTMS/S_PLN_EX_RES_FOR_ST> TYPE /SCMTMS/S_PLN_EX_RES_FOR_ST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_PLN_EX_RES_FOR_ST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCMTMS/S_PLN_EX_RES_FOR_ST INTO TABLE IT_/SCMTMS/S_PLN_EX_RES_FOR_ST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCMTMS/S_PLN_EX_RES_FOR_ST * INTO TABLE @DATA(IT_/SCMTMS/S_PLN_EX_RES_FOR_ST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCMTMS/S_PLN_EX_RES_FOR_ST INDEX 1 INTO DATA(WA_/SCMTMS/S_PLN_EX_RES_FOR_ST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCMTMS/S_PLN_EX_RES_FOR_ST ASSIGNING </SCMTMS/S_PLN_EX_RES_FOR_ST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_PLN_EX_RES_FOR_ST>-SOL_ID = 1.
</SCMTMS/S_PLN_EX_RES_FOR_ST>-FOR_UUID = 1.
</SCMTMS/S_PLN_EX_RES_FOR_ST>-FOR_ID = 1.
</SCMTMS/S_PLN_EX_RES_FOR_ST>-CAT = 1.
</SCMTMS/S_PLN_EX_RES_FOR_ST>-TU_CAT = 1.
ENDLOOP. LOOP AT IT_/SCMTMS/S_PLN_EX_RES_FOR_ST INTO WA_/SCMTMS/S_PLN_EX_RES_FOR_ST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-STAGE_ID, sy-vline,
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-SOURCE_LOC, sy-vline,
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-TARGET_LOC, sy-vline,
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-STAGE_WITH_SUB_STOP, sy-vline,
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DISTANCE, sy-vline,
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DURATION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_PLN_EX_RES_FOR_ST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_PLN_EX_RES_FOR_ST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_PLN_EX_RES_FOR_ST INTO WA_/SCMTMS/S_PLN_EX_RES_FOR_ST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit EXP01, internal->external for field FOR_UUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-FOR_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-FOR_UUID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FOR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-FOR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-FOR_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STAGE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-STAGE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-STAGE_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXP01, internal->external for field SOURCE_LOC CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-SOURCE_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-SOURCE_LOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXP01, internal->external for field TARGET_LOC CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-TARGET_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-TARGET_LOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTRN, internal->external for field DURATION CALL FUNCTION 'CONVERSION_EXIT_TSTRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DURATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DURATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit EXP01, internal->external for field DEF_ROUTE_UUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DEF_ROUTE_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DEF_ROUTE_UUID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DEF_ROUTE_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DEF_ROUTE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_RES_FOR_ST-DEF_ROUTE_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR,
SOL_ID TYPE STRING,
FOR_UUID TYPE STRING,
FOR_ID TYPE STRING,
CAT TYPE STRING,
TU_CAT TYPE STRING,
STAGE_ID TYPE STRING,
SOURCE_LOC TYPE STRING,
TARGET_LOC TYPE STRING,
STAGE_WITH_SUB_STOP TYPE STRING,
DISTANCE TYPE STRING,
DURATION TYPE STRING,
LOAD_START TYPE STRING,
LOAD_END TYPE STRING,
TRANSP_START TYPE STRING,
TRANSP_END TYPE STRING,
SOURCE_STOP TYPE STRING,
TARGET_STOP TYPE STRING,
MOT TYPE STRING,
DEF_ROUTE_UUID TYPE STRING,
DEF_ROUTE_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-SOL_ID sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-FOR_UUID sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-FOR_ID sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-CAT sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-TU_CAT sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-STAGE_ID sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-SOURCE_LOC sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-TARGET_LOC sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-STAGE_WITH_SUB_STOP sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-DISTANCE sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-DURATION sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-LOAD_START sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-LOAD_END sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-TRANSP_START sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-TRANSP_END sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-SOURCE_STOP sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-TARGET_STOP sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-MOT sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-DEF_ROUTE_UUID sy-vline
WA_/SCMTMS/S_PLN_EX_RES_FOR_ST_STR-DEF_ROUTE_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.