ABAP Select data from SAP table /SCMTMS/S_PLN_EX_TOUR_UL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_PLN_EX_TOUR_UL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_PLN_EX_TOUR_UL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_PLN_EX_TOUR_UL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_PLN_EX_TOUR_UL TYPE STANDARD TABLE OF /SCMTMS/S_PLN_EX_TOUR_UL,
      WA_/SCMTMS/S_PLN_EX_TOUR_UL TYPE /SCMTMS/S_PLN_EX_TOUR_UL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_PLN_EX_TOUR_UL> TYPE /SCMTMS/S_PLN_EX_TOUR_UL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_PLN_EX_TOUR_UL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_PLN_EX_TOUR_UL
  INTO TABLE IT_/SCMTMS/S_PLN_EX_TOUR_UL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_PLN_EX_TOUR_UL
*  INTO TABLE @DATA(IT_/SCMTMS/S_PLN_EX_TOUR_UL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_PLN_EX_TOUR_UL INDEX 1 INTO DATA(WA_/SCMTMS/S_PLN_EX_TOUR_UL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_PLN_EX_TOUR_UL ASSIGNING </SCMTMS/S_PLN_EX_TOUR_UL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_PLN_EX_TOUR_UL>-SOL_ID = 1.
</SCMTMS/S_PLN_EX_TOUR_UL>-TOUR_GUID = 1.
</SCMTMS/S_PLN_EX_TOUR_UL>-DIM_GUID = 1.
</SCMTMS/S_PLN_EX_TOUR_UL>-CAPA = 1.
</SCMTMS/S_PLN_EX_TOUR_UL>-ADJUSTED_CAPA = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_PLN_EX_TOUR_UL INTO WA_/SCMTMS/S_PLN_EX_TOUR_UL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_PLN_EX_TOUR_UL-USED_CAPA, sy-vline,
WA_/SCMTMS/S_PLN_EX_TOUR_UL-UTILIZATION_ADJUSTED_CAPA, sy-vline,
WA_/SCMTMS/S_PLN_EX_TOUR_UL-UTILIZATION, sy-vline,
WA_/SCMTMS/S_PLN_EX_TOUR_UL-MIN_TARGET_CAPA_USAGE, sy-vline,
WA_/SCMTMS/S_PLN_EX_TOUR_UL-MIN_TARGET_UTILIZATION, sy-vline,
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_PLN_EX_TOUR_UL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_PLN_EX_TOUR_UL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_PLN_EX_TOUR_UL INTO WA_/SCMTMS/S_PLN_EX_TOUR_UL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXP01, internal->external for field TOUR_GUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-TOUR_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-TOUR_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field DIM_GUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-DIM_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-DIM_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field CAPA CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-CAPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-CAPA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field ADJUSTED_CAPA CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-ADJUSTED_CAPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-ADJUSTED_CAPA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field USED_CAPA CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-USED_CAPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-USED_CAPA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field UTILIZATION_ADJUSTED_CAPA CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-UTILIZATION_ADJUSTED_CAPA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-UTILIZATION_ADJUSTED_CAPA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field UTILIZATION CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-UTILIZATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-UTILIZATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field MIN_TARGET_CAPA_USAGE CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-MIN_TARGET_CAPA_USAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-MIN_TARGET_CAPA_USAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field MIN_TARGET_UTILIZATION CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_TOUR_UL-MIN_TARGET_UTILIZATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_TOUR_UL-MIN_TARGET_UTILIZATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_PLN_EX_TOUR_UL_STR,
SOL_ID TYPE STRING,
TOUR_GUID TYPE STRING,
DIM_GUID TYPE STRING,
CAPA TYPE STRING,
ADJUSTED_CAPA TYPE STRING,
USED_CAPA TYPE STRING,
UTILIZATION_ADJUSTED_CAPA TYPE STRING,
UTILIZATION TYPE STRING,
MIN_TARGET_CAPA_USAGE TYPE STRING,
MIN_TARGET_UTILIZATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-SOL_ID sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-TOUR_GUID sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-DIM_GUID sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-CAPA sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-ADJUSTED_CAPA sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-USED_CAPA sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-UTILIZATION_ADJUSTED_CAPA sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-UTILIZATION sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-MIN_TARGET_CAPA_USAGE sy-vline
WA_/SCMTMS/S_PLN_EX_TOUR_UL_STR-MIN_TARGET_UTILIZATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.