ABAP Select data from SAP table /SCMTMS/S_QUERY_ENHANCE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_QUERY_ENHANCE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_QUERY_ENHANCE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCMTMS/S_QUERY_ENHANCE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCMTMS/S_QUERY_ENHANCE TYPE STANDARD TABLE OF /SCMTMS/S_QUERY_ENHANCE, WA_/SCMTMS/S_QUERY_ENHANCE TYPE /SCMTMS/S_QUERY_ENHANCE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCMTMS/S_QUERY_ENHANCE> TYPE /SCMTMS/S_QUERY_ENHANCE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_QUERY_ENHANCE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCMTMS/S_QUERY_ENHANCE INTO TABLE IT_/SCMTMS/S_QUERY_ENHANCE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCMTMS/S_QUERY_ENHANCE * INTO TABLE @DATA(IT_/SCMTMS/S_QUERY_ENHANCE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCMTMS/S_QUERY_ENHANCE INDEX 1 INTO DATA(WA_/SCMTMS/S_QUERY_ENHANCE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCMTMS/S_QUERY_ENHANCE ASSIGNING </SCMTMS/S_QUERY_ENHANCE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_QUERY_ENHANCE>-QUERY_CAT = 1.
</SCMTMS/S_QUERY_ENHANCE>-QUERY_KEY = 1.
</SCMTMS/S_QUERY_ENHANCE>-ATTR_NODE_KEY = 1.
</SCMTMS/S_QUERY_ENHANCE>-SRC_DB_NAME = 1.
</SCMTMS/S_QUERY_ENHANCE>-DB_COUNTER = 1.
ENDLOOP. LOOP AT IT_/SCMTMS/S_QUERY_ENHANCE INTO WA_/SCMTMS/S_QUERY_ENHANCE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCMTMS/S_QUERY_ENHANCE-NODE_ATTR, sy-vline,
WA_/SCMTMS/S_QUERY_ENHANCE-EXT_BO_KEY, sy-vline,
WA_/SCMTMS/S_QUERY_ENHANCE-EXT_NODE_KEY, sy-vline,
WA_/SCMTMS/S_QUERY_ENHANCE-TRGT_DB_NAME, sy-vline,
WA_/SCMTMS/S_QUERY_ENHANCE-TRGT_DB_COUNTER, sy-vline,
WA_/SCMTMS/S_QUERY_ENHANCE-NODE_JOIN_ATTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_QUERY_ENHANCE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_QUERY_ENHANCE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_QUERY_ENHANCE INTO WA_/SCMTMS/S_QUERY_ENHANCE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_QUERY_ENHANCE_STR,
QUERY_CAT TYPE STRING,
QUERY_KEY TYPE STRING,
ATTR_NODE_KEY TYPE STRING,
SRC_DB_NAME TYPE STRING,
DB_COUNTER TYPE STRING,
NODE_ATTR TYPE STRING,
EXT_BO_KEY TYPE STRING,
EXT_NODE_KEY TYPE STRING,
TRGT_DB_NAME TYPE STRING,
TRGT_DB_COUNTER TYPE STRING,
NODE_JOIN_ATTR TYPE STRING,
TRGT_JOIN_ATTR TYPE STRING,
NODE_JOIN_ATTR2 TYPE STRING,
TRGT_JOIN_ATTR2 TYPE STRING,
ND_JN_ATTR2_VAL TYPE STRING,
ND_JN_ATTR2_C TYPE STRING,
NODE_JOIN_ATTR3 TYPE STRING,
ND_JN_ATTR3_VAL TYPE STRING,
ND_JN_ATTR3_C TYPE STRING,
QUERY_ATTR TYPE STRING,
QUERY_ATTR_GRPID TYPE STRING,
FILTER_AFTER_SELECTION TYPE STRING,
NO_ALPHA_CONV TYPE STRING,
S_SUBQUERY_EXISTS TYPE STRING,
SRC_DB_COUNTER TYPE STRING,
SRC_DB_NAME TYPE STRING,
NODE_JOIN_ATTR TYPE STRING,
TRGT_JOIN_ATTR TYPE STRING,
NEGATIVE_SUBQUERY TYPE STRING,
T_ENHANCE_DEF TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_QUERY_ENHANCE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-QUERY_CAT sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-QUERY_KEY sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-ATTR_NODE_KEY sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-SRC_DB_NAME sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-DB_COUNTER sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NODE_ATTR sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-EXT_BO_KEY sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-EXT_NODE_KEY sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-TRGT_DB_NAME sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-TRGT_DB_COUNTER sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NODE_JOIN_ATTR sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-TRGT_JOIN_ATTR sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NODE_JOIN_ATTR2 sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-TRGT_JOIN_ATTR2 sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-ND_JN_ATTR2_VAL sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-ND_JN_ATTR2_C sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NODE_JOIN_ATTR3 sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-ND_JN_ATTR3_VAL sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-ND_JN_ATTR3_C sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-QUERY_ATTR sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-QUERY_ATTR_GRPID sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-FILTER_AFTER_SELECTION sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NO_ALPHA_CONV sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-S_SUBQUERY_EXISTS sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-SRC_DB_COUNTER sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-SRC_DB_NAME sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NODE_JOIN_ATTR sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-TRGT_JOIN_ATTR sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-NEGATIVE_SUBQUERY sy-vline
WA_/SCMTMS/S_QUERY_ENHANCE_STR-T_ENHANCE_DEF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.