ABAP Select data from SAP table /SCMTMS/S_TOR_STOP_SUCC_UTIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_TOR_STOP_SUCC_UTIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_TOR_STOP_SUCC_UTIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_TOR_STOP_SUCC_UTIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL TYPE STANDARD TABLE OF /SCMTMS/S_TOR_STOP_SUCC_UTIL,
      WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL TYPE /SCMTMS/S_TOR_STOP_SUCC_UTIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_TOR_STOP_SUCC_UTIL> TYPE /SCMTMS/S_TOR_STOP_SUCC_UTIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_TOR_STOP_SUCC_UTIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_TOR_STOP_SUCC_UTIL
  INTO TABLE IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_TOR_STOP_SUCC_UTIL
*  INTO TABLE @DATA(IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL INDEX 1 INTO DATA(WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL ASSIGNING </SCMTMS/S_TOR_STOP_SUCC_UTIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_TOR_STOP_SUCC_UTIL>-ITEM_KEY = 1.
</SCMTMS/S_TOR_STOP_SUCC_UTIL>-USED_WEI_VAL = 1.
</SCMTMS/S_TOR_STOP_SUCC_UTIL>-USED_WEI_UNI = 1.
</SCMTMS/S_TOR_STOP_SUCC_UTIL>-USED_VOL_VAL = 1.
</SCMTMS/S_TOR_STOP_SUCC_UTIL>-USED_VOL_UNI = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL INTO WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_NLQ_VAL, sy-vline,
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_NLQ_UNI, sy-vline,
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_WEI_VAL, sy-vline,
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_WEI_UNI, sy-vline,
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_VOL_VAL, sy-vline,
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_VOL_UNI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_TOR_STOP_SUCC_UTIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_TOR_STOP_SUCC_UTIL INTO WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit QTYRN, internal->external for field USED_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USED_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field USED_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USED_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field USED_NLQ_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_NLQ_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_NLQ_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USED_NLQ_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_NLQ_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-USED_NLQ_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field OPEN_CAP_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OPEN_CAP_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field OPEN_CAP_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OPEN_CAP_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field OPEN_CAP_NLQ_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_NLQ_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_NLQ_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OPEN_CAP_NLQ_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_NLQ_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL-OPEN_CAP_NLQ_UNI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR,
ITEM_KEY TYPE STRING,
USED_WEI_VAL TYPE STRING,
USED_WEI_UNI TYPE STRING,
USED_VOL_VAL TYPE STRING,
USED_VOL_UNI TYPE STRING,
USED_NLQ_VAL TYPE STRING,
USED_NLQ_UNI TYPE STRING,
OPEN_CAP_WEI_VAL TYPE STRING,
OPEN_CAP_WEI_UNI TYPE STRING,
OPEN_CAP_VOL_VAL TYPE STRING,
OPEN_CAP_VOL_UNI TYPE STRING,
OPEN_CAP_NLQ_VAL TYPE STRING,
OPEN_CAP_NLQ_UNI TYPE STRING,
UTIL_MASS TYPE STRING,
UTIL_VOLUME TYPE STRING,
UTIL_LENGTH TYPE STRING,
UTIL_DIMLESS TYPE STRING,
UTIL_NLQ TYPE STRING,
UTIL_MAX TYPE STRING,
CRITICAL TYPE STRING,
STGLEAD TYPE STRING,
DOCLEAD TYPE STRING,
EEW_TOR_STSUTIL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-ITEM_KEY sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-USED_WEI_VAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-USED_WEI_UNI sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-USED_VOL_VAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-USED_VOL_UNI sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-USED_NLQ_VAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-USED_NLQ_UNI sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-OPEN_CAP_WEI_VAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-OPEN_CAP_WEI_UNI sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-OPEN_CAP_VOL_VAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-OPEN_CAP_VOL_UNI sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-OPEN_CAP_NLQ_VAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-OPEN_CAP_NLQ_UNI sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-UTIL_MASS sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-UTIL_VOLUME sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-UTIL_LENGTH sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-UTIL_DIMLESS sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-UTIL_NLQ sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-UTIL_MAX sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-CRITICAL sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-STGLEAD sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-DOCLEAD sy-vline
WA_/SCMTMS/S_TOR_STOP_SUCC_UTIL_STR-EEW_TOR_STSUTIL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.