ABAP Select data from SAP table /SCWM/PS_WVC_LOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/PS_WVC_LOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/PS_WVC_LOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/PS_WVC_LOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/PS_WVC_LOG TYPE STANDARD TABLE OF /SCWM/PS_WVC_LOG,
      WA_/SCWM/PS_WVC_LOG TYPE /SCWM/PS_WVC_LOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/PS_WVC_LOG> TYPE /SCWM/PS_WVC_LOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/PS_WVC_LOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/PS_WVC_LOG
  INTO TABLE IT_/SCWM/PS_WVC_LOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/PS_WVC_LOG
*  INTO TABLE @DATA(IT_/SCWM/PS_WVC_LOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/PS_WVC_LOG INDEX 1 INTO DATA(WA_/SCWM/PS_WVC_LOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/PS_WVC_LOG ASSIGNING </SCWM/PS_WVC_LOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/PS_WVC_LOG>-PS_ID = 1.
</SCWM/PS_WVC_LOG>-LEVEL_SEQ = 1.
</SCWM/PS_WVC_LOG>-PRODUCT = 1.
</SCWM/PS_WVC_LOG>-G_WEIGHT = 1.
</SCWM/PS_WVC_LOG>-UNIT_GW = 1.
ENDLOOP.

LOOP AT IT_/SCWM/PS_WVC_LOG INTO WA_/SCWM/PS_WVC_LOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/PS_WVC_LOG-T_WEIGHT, sy-vline,
WA_/SCWM/PS_WVC_LOG-UNIT_TW, sy-vline,
WA_/SCWM/PS_WVC_LOG-G_VOLUME, sy-vline,
WA_/SCWM/PS_WVC_LOG-UNIT_GV, sy-vline,
WA_/SCWM/PS_WVC_LOG-T_VOLUME, sy-vline,
WA_/SCWM/PS_WVC_LOG-UNIT_TV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/PS_WVC_LOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/PS_WVC_LOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/PS_WVC_LOG INTO WA_/SCWM/PS_WVC_LOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PS_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-PS_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-PS_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LEVEL_SEQ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-LEVEL_SEQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-LEVEL_SEQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_GW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_GW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_TW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_TW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_GV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_GV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_TV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_TV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GW2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_GW2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_GW2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TW2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_TW2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_TW2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GV2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_GV2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_GV2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TV2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/PS_WVC_LOG-UNIT_TV2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/PS_WVC_LOG-UNIT_TV2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/PS_WVC_LOG_STR,
PS_ID TYPE STRING,
LEVEL_SEQ TYPE STRING,
PRODUCT TYPE STRING,
G_WEIGHT TYPE STRING,
UNIT_GW TYPE STRING,
T_WEIGHT TYPE STRING,
UNIT_TW TYPE STRING,
G_VOLUME TYPE STRING,
UNIT_GV TYPE STRING,
T_VOLUME TYPE STRING,
UNIT_TV TYPE STRING,
G_CAPA TYPE STRING,
T_CAPA TYPE STRING,
CAL_VAL_TXT TYPE STRING,
G_WEIGHT2 TYPE STRING,
UNIT_GW2 TYPE STRING,
T_WEIGHT2 TYPE STRING,
UNIT_TW2 TYPE STRING,
G_VOLUME2 TYPE STRING,
UNIT_GV2 TYPE STRING,
T_VOLUME2 TYPE STRING,
UNIT_TV2 TYPE STRING,
G_CAPA2 TYPE STRING,
T_CAPA2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/PS_WVC_LOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/PS_WVC_LOG_STR-PS_ID sy-vline
WA_/SCWM/PS_WVC_LOG_STR-LEVEL_SEQ sy-vline
WA_/SCWM/PS_WVC_LOG_STR-PRODUCT sy-vline
WA_/SCWM/PS_WVC_LOG_STR-G_WEIGHT sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_GW sy-vline
WA_/SCWM/PS_WVC_LOG_STR-T_WEIGHT sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_TW sy-vline
WA_/SCWM/PS_WVC_LOG_STR-G_VOLUME sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_GV sy-vline
WA_/SCWM/PS_WVC_LOG_STR-T_VOLUME sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_TV sy-vline
WA_/SCWM/PS_WVC_LOG_STR-G_CAPA sy-vline
WA_/SCWM/PS_WVC_LOG_STR-T_CAPA sy-vline
WA_/SCWM/PS_WVC_LOG_STR-CAL_VAL_TXT sy-vline
WA_/SCWM/PS_WVC_LOG_STR-G_WEIGHT2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_GW2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-T_WEIGHT2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_TW2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-G_VOLUME2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_GV2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-T_VOLUME2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-UNIT_TV2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-G_CAPA2 sy-vline
WA_/SCWM/PS_WVC_LOG_STR-T_CAPA2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.