ABAP Select data from SAP table /SCWM/S_DLV_SCO_ITEM_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_DLV_SCO_ITEM_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_DLV_SCO_ITEM_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_DLV_SCO_ITEM_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_DLV_SCO_ITEM_DATA TYPE STANDARD TABLE OF /SCWM/S_DLV_SCO_ITEM_DATA, WA_/SCWM/S_DLV_SCO_ITEM_DATA TYPE /SCWM/S_DLV_SCO_ITEM_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_DLV_SCO_ITEM_DATA> TYPE /SCWM/S_DLV_SCO_ITEM_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_DLV_SCO_ITEM_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_DLV_SCO_ITEM_DATA INTO TABLE IT_/SCWM/S_DLV_SCO_ITEM_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_DLV_SCO_ITEM_DATA * INTO TABLE @DATA(IT_/SCWM/S_DLV_SCO_ITEM_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_DLV_SCO_ITEM_DATA INDEX 1 INTO DATA(WA_/SCWM/S_DLV_SCO_ITEM_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_DLV_SCO_ITEM_DATA ASSIGNING </SCWM/S_DLV_SCO_ITEM_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_DLV_SCO_ITEM_DATA>-DOCID = 1.
</SCWM/S_DLV_SCO_ITEM_DATA>-PRIORITY = 1.
</SCWM/S_DLV_SCO_ITEM_DATA>-REFDOCNO_SO = 1.
</SCWM/S_DLV_SCO_ITEM_DATA>-REFDOCNO_PO = 1.
</SCWM/S_DLV_SCO_ITEM_DATA>-GI_DATE = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_DLV_SCO_ITEM_DATA INTO WA_/SCWM/S_DLV_SCO_ITEM_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_DLV_SCO_ITEM_DATA-GI_TIME, sy-vline,
WA_/SCWM/S_DLV_SCO_ITEM_DATA-/SCWM/DOOR, sy-vline,
WA_/SCWM/S_DLV_SCO_ITEM_DATA-/SCWM/STAGARBIN, sy-vline,
WA_/SCWM/S_DLV_SCO_ITEM_DATA-/SCWM/STAGAREA, sy-vline,
WA_/SCWM/S_DLV_SCO_ITEM_DATA-/SCWM/STAGAREAGR, sy-vline,
WA_/SCWM/S_DLV_SCO_ITEM_DATA-/SCWM/DGIND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_DLV_SCO_ITEM_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_DLV_SCO_ITEM_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_DLV_SCO_ITEM_DATA INTO WA_/SCWM/S_DLV_SCO_ITEM_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field REFDOCNO_SO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_DLV_SCO_ITEM_DATA-REFDOCNO_SO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DLV_SCO_ITEM_DATA-REFDOCNO_SO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REFDOCNO_PO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_DLV_SCO_ITEM_DATA-REFDOCNO_PO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DLV_SCO_ITEM_DATA-REFDOCNO_PO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field WEIGHT_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_DLV_SCO_ITEM_DATA-WEIGHT_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DLV_SCO_ITEM_DATA-WEIGHT_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOLUME_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_DLV_SCO_ITEM_DATA-VOLUME_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DLV_SCO_ITEM_DATA-VOLUME_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_DLV_SCO_ITEM_DATA_STR,
DOCID TYPE STRING,
PRIORITY TYPE STRING,
REFDOCNO_SO TYPE STRING,
REFDOCNO_PO TYPE STRING,
GI_DATE TYPE STRING,
GI_TIME TYPE STRING,
/SCWM/DOOR TYPE STRING,
/SCWM/STAGARBIN TYPE STRING,
/SCWM/STAGAREA TYPE STRING,
/SCWM/STAGAREAGR TYPE STRING,
/SCWM/DGIND TYPE STRING,
SERVICE_LEVEL TYPE STRING,
WEIGHT_INT TYPE STRING,
WEIGHT_UOM TYPE STRING,
VOLUME_INT TYPE STRING,
VOLUME_UOM TYPE STRING,
NUMBER_OF_PRDO_ITEMS TYPE STRING,
NUMBER_OF_ITEMS_WO_WAVE TYPE STRING,
NUMBER_OF_WAVE_REL_ITEMS TYPE STRING,
NUMBER_OF_WT_REL_ITEMS TYPE STRING,
STATUS_STAGR_PLAN TYPE STRING,
STATUS_WAVE_PLAN TYPE STRING,
STATUS_PICK_PLAN TYPE STRING,
STATUS_PICK TYPE STRING,
STATUS_PICK_ACT_DATE TYPE STRING,
STATUS_PICK_ACT_TIME TYPE STRING,
STATUS_LOAD TYPE STRING,
STATUS_LOAD_ACT_DATE TYPE STRING,
STATUS_LOAD_ACT_TIME TYPE STRING,
STATUS_GI TYPE STRING,
STATUS_GI_ACT_DATE TYPE STRING,
STATUS_GI_ACT_TIME TYPE STRING,
STATUS_DISTRIBUTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-DOCID sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-PRIORITY sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-REFDOCNO_SO sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-REFDOCNO_PO sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-GI_DATE sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-GI_TIME sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-/SCWM/DOOR sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-/SCWM/STAGARBIN sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-/SCWM/STAGAREA sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-/SCWM/STAGAREAGR sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-/SCWM/DGIND sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-SERVICE_LEVEL sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-WEIGHT_INT sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-WEIGHT_UOM sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-VOLUME_INT sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-VOLUME_UOM sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-NUMBER_OF_PRDO_ITEMS sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-NUMBER_OF_ITEMS_WO_WAVE sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-NUMBER_OF_WAVE_REL_ITEMS sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-NUMBER_OF_WT_REL_ITEMS sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_STAGR_PLAN sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_WAVE_PLAN sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_PICK_PLAN sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_PICK sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_PICK_ACT_DATE sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_PICK_ACT_TIME sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_LOAD sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_LOAD_ACT_DATE sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_LOAD_ACT_TIME sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_GI sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_GI_ACT_DATE sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_GI_ACT_TIME sy-vline
WA_/SCWM/S_DLV_SCO_ITEM_DATA_STR-STATUS_DISTRIBUTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.