ABAP Select data from SAP table /SCWM/S_DSLP_ROOT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_DSLP_ROOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_DSLP_ROOT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_DSLP_ROOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_DSLP_ROOT TYPE STANDARD TABLE OF /SCWM/S_DSLP_ROOT, WA_/SCWM/S_DSLP_ROOT TYPE /SCWM/S_DSLP_ROOT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_DSLP_ROOT> TYPE /SCWM/S_DSLP_ROOT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_DSLP_ROOT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_DSLP_ROOT INTO TABLE IT_/SCWM/S_DSLP_ROOT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_DSLP_ROOT * INTO TABLE @DATA(IT_/SCWM/S_DSLP_ROOT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_DSLP_ROOT INDEX 1 INTO DATA(WA_/SCWM/S_DSLP_ROOT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_DSLP_ROOT ASSIGNING </SCWM/S_DSLP_ROOT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_DSLP_ROOT>-LOADPOINT = 1.
</SCWM/S_DSLP_ROOT>-CAL = 1.
</SCWM/S_DSLP_ROOT>-SLOTDURA = 1.
</SCWM/S_DSLP_ROOT>-SLOTMIN = 1.
</SCWM/S_DSLP_ROOT>-SLOTMAX = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_DSLP_ROOT INTO WA_/SCWM/S_DSLP_ROOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_DSLP_ROOT-NUMRIN, sy-vline,
WA_/SCWM/S_DSLP_ROOT-LPTYPE, sy-vline,
WA_/SCWM/S_DSLP_ROOT-LP_PARENT, sy-vline,
WA_/SCWM/S_DSLP_ROOT-LPLOCA, sy-vline,
WA_/SCWM/S_DSLP_ROOT-EWMINT, sy-vline,
WA_/SCWM/S_DSLP_ROOT-PLHOR_IND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_DSLP_ROOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_DSLP_ROOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_DSLP_ROOT INTO WA_/SCWM/S_DSLP_ROOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit DSTST, internal->external for field SLOTMIN CALL FUNCTION 'CONVERSION_EXIT_DSTST_OUTPUT' EXPORTING input = WA_/SCWM/S_DSLP_ROOT-SLOTMIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DSLP_ROOT-SLOTMIN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit DSTST, internal->external for field SLOTMAX CALL FUNCTION 'CONVERSION_EXIT_DSTST_OUTPUT' EXPORTING input = WA_/SCWM/S_DSLP_ROOT-SLOTMAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DSLP_ROOT-SLOTMAX.
WRITE:/ 'New Value:', ld_input.
*Conversion exit DSDUR, internal->external for field APP_LEAD_TIME CALL FUNCTION 'CONVERSION_EXIT_DSDUR_OUTPUT' EXPORTING input = WA_/SCWM/S_DSLP_ROOT-APP_LEAD_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DSLP_ROOT-APP_LEAD_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_DSLP_ROOT-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DSLP_ROOT-CREATED_ON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_DSLP_ROOT-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_DSLP_ROOT-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_DSLP_ROOT_STR,
LOADPOINT TYPE STRING,
CAL TYPE STRING,
SLOTDURA TYPE STRING,
SLOTMIN TYPE STRING,
SLOTMAX TYPE STRING,
NUMRIN TYPE STRING,
LPTYPE TYPE STRING,
LP_PARENT TYPE STRING,
LPLOCA TYPE STRING,
EWMINT TYPE STRING,
PLHOR_IND TYPE STRING,
PLHOR_REL_HOURS TYPE STRING,
PLHOR_ABS_DAYS TYPE STRING,
PLHOR_ABS_TIME TYPE STRING,
APP_LEAD_TIME TYPE STRING,
VAR_LENGTH_IND TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
EEW_DSLP_ROOT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_DSLP_ROOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-LOADPOINT sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-CAL sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-SLOTDURA sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-SLOTMIN sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-SLOTMAX sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-NUMRIN sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-LPTYPE sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-LP_PARENT sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-LPLOCA sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-EWMINT sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-PLHOR_IND sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-PLHOR_REL_HOURS sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-PLHOR_ABS_DAYS sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-PLHOR_ABS_TIME sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-APP_LEAD_TIME sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-VAR_LENGTH_IND sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-CREATED_BY sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-CREATED_ON sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-CHANGED_BY sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-CHANGED_ON sy-vline
WA_/SCWM/S_DSLP_ROOT_STR-EEW_DSLP_ROOT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.