ABAP Select data from SAP table /SCWM/S_EXCEP_INSP_OUT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_EXCEP_INSP_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_EXCEP_INSP_OUT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_EXCEP_INSP_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_EXCEP_INSP_OUT TYPE STANDARD TABLE OF /SCWM/S_EXCEP_INSP_OUT, WA_/SCWM/S_EXCEP_INSP_OUT TYPE /SCWM/S_EXCEP_INSP_OUT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_EXCEP_INSP_OUT> TYPE /SCWM/S_EXCEP_INSP_OUT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_EXCEP_INSP_OUT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_EXCEP_INSP_OUT INTO TABLE IT_/SCWM/S_EXCEP_INSP_OUT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_EXCEP_INSP_OUT * INTO TABLE @DATA(IT_/SCWM/S_EXCEP_INSP_OUT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_EXCEP_INSP_OUT INDEX 1 INTO DATA(WA_/SCWM/S_EXCEP_INSP_OUT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_EXCEP_INSP_OUT ASSIGNING </SCWM/S_EXCEP_INSP_OUT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_EXCEP_INSP_OUT>-INSP_DOC_NUMBER = 1.
</SCWM/S_EXCEP_INSP_OUT>-LOT_SIZE = 1.
</SCWM/S_EXCEP_INSP_OUT>-LOT_UNIT = 1.
</SCWM/S_EXCEP_INSP_OUT>-INSP_STAG_ID = 1.
</SCWM/S_EXCEP_INSP_OUT>-SKIP = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_EXCEP_INSP_OUT INTO WA_/SCWM/S_EXCEP_INSP_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_EXCEP_INSP_OUT-INSP_PROC, sy-vline,
WA_/SCWM/S_EXCEP_INSP_OUT-DMOD_RULE_ID, sy-vline,
WA_/SCWM/S_EXCEP_INSP_OUT-DCOD_BUND_ID, sy-vline,
WA_/SCWM/S_EXCEP_INSP_OUT-DMOD_CRIT_ID, sy-vline,
WA_/SCWM/S_EXCEP_INSP_OUT-AUTH_GROUP, sy-vline,
WA_/SCWM/S_EXCEP_INSP_OUT-SAMPLE_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_EXCEP_INSP_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_EXCEP_INSP_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_EXCEP_INSP_OUT INTO WA_/SCWM/S_EXCEP_INSP_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field INSP_DOC_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-INSP_DOC_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-INSP_DOC_NUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LOT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-LOT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-LOT_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field SAMPLE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-SAMPLE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-SAMPLE_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field DECIDED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-DECIDED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-DECIDED_ON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-CREATED_ON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EXTERNAL_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_EXCEP_INSP_OUT-EXTERNAL_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EXCEP_INSP_OUT-EXTERNAL_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_EXCEP_INSP_OUT_STR,
INSP_DOC_NUMBER TYPE STRING,
LOT_SIZE TYPE STRING,
LOT_UNIT TYPE STRING,
INSP_STAG_ID TYPE STRING,
SKIP TYPE STRING,
INSP_PROC TYPE STRING,
DMOD_RULE_ID TYPE STRING,
DCOD_BUND_ID TYPE STRING,
DMOD_CRIT_ID TYPE STRING,
AUTH_GROUP TYPE STRING,
SAMPLE_TYPE TYPE STRING,
SAMPLE_SIZE_FIX TYPE STRING,
SAMPLE_UNIT TYPE STRING,
NUMB_ACCEPT TYPE STRING,
SAMPLE_SIZE_PRC TYPE STRING,
NUMB_ACCEPT_PRC TYPE STRING,
SAMP_SCHM_ID TYPE STRING,
INSP_LEVEL TYPE STRING,
INSP_SEVERITY TYPE STRING,
AQL_VALUE TYPE STRING,
CRULE_SAMPSIZE TYPE STRING,
VALUATION_MODE TYPE STRING,
NR_RANGE_ID TYPE STRING,
ITEM_DCBD_ID TYPE STRING,
ELEMENT_TYPE TYPE STRING,
SAMP_DCBD_ID TYPE STRING,
FIND_TYPE_ID TYPE STRING,
CAT_FILTER_ID TYPE STRING,
DUMMY TYPE STRING,
DEFGRP TYPE STRING,
PROCS TYPE STRING,
RLGRP TYPE STRING,
CATLOCN TYPE STRING,
AUTO_DECIDED TYPE STRING,
DECI_CODE_ID TYPE STRING,
QUALITY_SCORE TYPE STRING,
DMOD_VALUATION TYPE STRING,
PROP_VALUATION TYPE STRING,
INSP_VALUATION TYPE STRING,
DECIDED_ON TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
EXTERNAL_ID TYPE STRING,
CATEGORY TYPE STRING,
SUB_CATEGORY TYPE STRING,
EXCCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_EXCEP_INSP_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-INSP_DOC_NUMBER sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-LOT_SIZE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-LOT_UNIT sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-INSP_STAG_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SKIP sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-INSP_PROC sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DMOD_RULE_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DCOD_BUND_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DMOD_CRIT_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-AUTH_GROUP sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SAMPLE_TYPE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SAMPLE_SIZE_FIX sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SAMPLE_UNIT sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-NUMB_ACCEPT sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SAMPLE_SIZE_PRC sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-NUMB_ACCEPT_PRC sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SAMP_SCHM_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-INSP_LEVEL sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-INSP_SEVERITY sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-AQL_VALUE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CRULE_SAMPSIZE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-VALUATION_MODE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-NR_RANGE_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-ITEM_DCBD_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-ELEMENT_TYPE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SAMP_DCBD_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-FIND_TYPE_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CAT_FILTER_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DUMMY sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DEFGRP sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-PROCS sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-RLGRP sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CATLOCN sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-AUTO_DECIDED sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DECI_CODE_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-QUALITY_SCORE sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DMOD_VALUATION sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-PROP_VALUATION sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-INSP_VALUATION sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-DECIDED_ON sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CREATED_BY sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CREATED_ON sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CHANGED_BY sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CHANGED_ON sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-EXTERNAL_ID sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-CATEGORY sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-SUB_CATEGORY sy-vline
WA_/SCWM/S_EXCEP_INSP_OUT_STR-EXCCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.