ABAP Select data from SAP table /SCWM/S_HUMAT_INT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_HUMAT_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_HUMAT_INT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_HUMAT_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_HUMAT_INT TYPE STANDARD TABLE OF /SCWM/S_HUMAT_INT, WA_/SCWM/S_HUMAT_INT TYPE /SCWM/S_HUMAT_INT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_HUMAT_INT> TYPE /SCWM/S_HUMAT_INT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_HUMAT_INT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_HUMAT_INT INTO TABLE IT_/SCWM/S_HUMAT_INT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_HUMAT_INT * INTO TABLE @DATA(IT_/SCWM/S_HUMAT_INT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_HUMAT_INT INDEX 1 INTO DATA(WA_/SCWM/S_HUMAT_INT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_HUMAT_INT ASSIGNING </SCWM/S_HUMAT_INT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_HUMAT_INT>-SELKZ = 1.
</SCWM/S_HUMAT_INT>-GUID_STOCK0 = 1.
</SCWM/S_HUMAT_INT>-IDX = 1.
</SCWM/S_HUMAT_INT>-MATNR = 1.
</SCWM/S_HUMAT_INT>-LGNUM = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_HUMAT_INT INTO WA_/SCWM/S_HUMAT_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_HUMAT_INT-MATID, sy-vline,
WA_/SCWM/S_HUMAT_INT-BATCHID, sy-vline,
WA_/SCWM/S_HUMAT_INT-CAT, sy-vline,
WA_/SCWM/S_HUMAT_INT-STOCK_DOCCAT, sy-vline,
WA_/SCWM/S_HUMAT_INT-STOCK_DOCNO, sy-vline,
WA_/SCWM/S_HUMAT_INT-STOCK_ITMNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_HUMAT_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_HUMAT_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_HUMAT_INT INTO WA_/SCWM/S_HUMAT_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-MATID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-OWNER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-ENTITLED.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-ALTME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LOGME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-LOGME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-LOGME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field CWUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-CWUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-CWUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-UNIT_W.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-UNIT_V.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field DIMEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-DIMEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-DIMEH.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MDLPD, internal->external for field RMATP CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_HUMAT_INT-RMATP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_HUMAT_INT-RMATP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_HUMAT_INT_STR,
SELKZ TYPE STRING,
GUID_STOCK0 TYPE STRING,
IDX TYPE STRING,
MATNR TYPE STRING,
LGNUM TYPE STRING,
MATID TYPE STRING,
BATCHID TYPE STRING,
CAT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_ITMNO TYPE STRING,
DOCCAT TYPE STRING,
STOCK_USAGE TYPE STRING,
OWNER TYPE STRING,
OWNER_ROLE TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_ROLE TYPE STRING,
STOCK_CNT TYPE STRING,
VSI TYPE STRING,
MAKTX TYPE STRING,
ALTME TYPE STRING,
TY2QT TYPE STRING,
MEINS TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
UMREF TYPE STRING,
LOGME TYPE STRING,
CWUNIT TYPE STRING,
CWUMREF TYPE STRING,
CWCAPA TYPE STRING,
T_WEIGHT TYPE STRING,
WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
VOLUME TYPE STRING,
UNIT_V TYPE STRING,
MAX_STACK TYPE STRING,
NEST_FTR TYPE STRING,
MKAPV TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
DIMEH TYPE STRING,
PACKGR TYPE STRING,
XCHAR TYPE STRING,
WDATU TYPE STRING,
VFDAT TYPE STRING,
COO TYPE STRING,
BRESTR TYPE STRING,
RMATP TYPE STRING,
BATCH_REQ TYPE STRING,
SN_STOCK TYPE STRING,
HZMT TYPE STRING,
PMTYP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_HUMAT_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_HUMAT_INT_STR-SELKZ sy-vline
WA_/SCWM/S_HUMAT_INT_STR-GUID_STOCK0 sy-vline
WA_/SCWM/S_HUMAT_INT_STR-IDX sy-vline
WA_/SCWM/S_HUMAT_INT_STR-MATNR sy-vline
WA_/SCWM/S_HUMAT_INT_STR-LGNUM sy-vline
WA_/SCWM/S_HUMAT_INT_STR-MATID sy-vline
WA_/SCWM/S_HUMAT_INT_STR-BATCHID sy-vline
WA_/SCWM/S_HUMAT_INT_STR-CAT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-STOCK_DOCNO sy-vline
WA_/SCWM/S_HUMAT_INT_STR-STOCK_ITMNO sy-vline
WA_/SCWM/S_HUMAT_INT_STR-DOCCAT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-STOCK_USAGE sy-vline
WA_/SCWM/S_HUMAT_INT_STR-OWNER sy-vline
WA_/SCWM/S_HUMAT_INT_STR-OWNER_ROLE sy-vline
WA_/SCWM/S_HUMAT_INT_STR-ENTITLED sy-vline
WA_/SCWM/S_HUMAT_INT_STR-ENTITLED_ROLE sy-vline
WA_/SCWM/S_HUMAT_INT_STR-STOCK_CNT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-VSI sy-vline
WA_/SCWM/S_HUMAT_INT_STR-MAKTX sy-vline
WA_/SCWM/S_HUMAT_INT_STR-ALTME sy-vline
WA_/SCWM/S_HUMAT_INT_STR-TY2QT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-MEINS sy-vline
WA_/SCWM/S_HUMAT_INT_STR-UMREZ sy-vline
WA_/SCWM/S_HUMAT_INT_STR-UMREN sy-vline
WA_/SCWM/S_HUMAT_INT_STR-UMREF sy-vline
WA_/SCWM/S_HUMAT_INT_STR-LOGME sy-vline
WA_/SCWM/S_HUMAT_INT_STR-CWUNIT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-CWUMREF sy-vline
WA_/SCWM/S_HUMAT_INT_STR-CWCAPA sy-vline
WA_/SCWM/S_HUMAT_INT_STR-T_WEIGHT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-WEIGHT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-UNIT_W sy-vline
WA_/SCWM/S_HUMAT_INT_STR-VOLUME sy-vline
WA_/SCWM/S_HUMAT_INT_STR-UNIT_V sy-vline
WA_/SCWM/S_HUMAT_INT_STR-MAX_STACK sy-vline
WA_/SCWM/S_HUMAT_INT_STR-NEST_FTR sy-vline
WA_/SCWM/S_HUMAT_INT_STR-MKAPV sy-vline
WA_/SCWM/S_HUMAT_INT_STR-LENGTH sy-vline
WA_/SCWM/S_HUMAT_INT_STR-WIDTH sy-vline
WA_/SCWM/S_HUMAT_INT_STR-HEIGHT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-DIMEH sy-vline
WA_/SCWM/S_HUMAT_INT_STR-PACKGR sy-vline
WA_/SCWM/S_HUMAT_INT_STR-XCHAR sy-vline
WA_/SCWM/S_HUMAT_INT_STR-WDATU sy-vline
WA_/SCWM/S_HUMAT_INT_STR-VFDAT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-COO sy-vline
WA_/SCWM/S_HUMAT_INT_STR-BRESTR sy-vline
WA_/SCWM/S_HUMAT_INT_STR-RMATP sy-vline
WA_/SCWM/S_HUMAT_INT_STR-BATCH_REQ sy-vline
WA_/SCWM/S_HUMAT_INT_STR-SN_STOCK sy-vline
WA_/SCWM/S_HUMAT_INT_STR-HZMT sy-vline
WA_/SCWM/S_HUMAT_INT_STR-PMTYP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.