ABAP Select data from SAP table /SCWM/S_ILT_INT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_ILT_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_ILT_INT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_ILT_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_ILT_INT TYPE STANDARD TABLE OF /SCWM/S_ILT_INT,
      WA_/SCWM/S_ILT_INT TYPE /SCWM/S_ILT_INT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_ILT_INT> TYPE /SCWM/S_ILT_INT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_ILT_INT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_ILT_INT
  INTO TABLE IT_/SCWM/S_ILT_INT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_ILT_INT
*  INTO TABLE @DATA(IT_/SCWM/S_ILT_INT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_ILT_INT INDEX 1 INTO DATA(WA_/SCWM/S_ILT_INT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_ILT_INT ASSIGNING </SCWM/S_ILT_INT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_ILT_INT>-INDLID = 1.
</SCWM/S_ILT_INT>-LGNUM = 1.
</SCWM/S_ILT_INT>-INDLNO = 1.
</SCWM/S_ILT_INT>-PROCS = 1.
</SCWM/S_ILT_INT>-PROCESSOR = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_ILT_INT INTO WA_/SCWM/S_ILT_INT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_ILT_INT-ENTITLED, sy-vline,
WA_/SCWM/S_ILT_INT-AAREA, sy-vline,
WA_/SCWM/S_ILT_INT-STATUS, sy-vline,
WA_/SCWM/S_ILT_INT-PLANDURA, sy-vline,
WA_/SCWM/S_ILT_INT-UNIT_T, sy-vline,
WA_/SCWM/S_ILT_INT-START_TSTAMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_ILT_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_ILT_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_ILT_INT INTO WA_/SCWM/S_ILT_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPH0, internal->external for field INDLNO CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-INDLNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-INDLNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PROCESSOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-PROCESSOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-PROCESSOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_T CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-UNIT_T IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-UNIT_T.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field START_TSTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-START_TSTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-START_TSTAMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field END_TSTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-END_TSTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-END_TSTAMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CRETST CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-CRETST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-CRETST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CHGTST CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_ILT_INT-CHGTST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ILT_INT-CHGTST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_ILT_INT_STR,
INDLID TYPE STRING,
LGNUM TYPE STRING,
INDLNO TYPE STRING,
PROCS TYPE STRING,
PROCESSOR TYPE STRING,
ENTITLED TYPE STRING,
AAREA TYPE STRING,
STATUS TYPE STRING,
PLANDURA TYPE STRING,
UNIT_T TYPE STRING,
START_TSTAMP TYPE STRING,
END_TSTAMP TYPE STRING,
EXCCODE TYPE STRING,
BUSCON TYPE STRING,
EXEC_STEP TYPE STRING,
NOTE TYPE STRING,
ALLOCTERM TYPE STRING,
CREUSR TYPE STRING,
CRETST TYPE STRING,
CHGUSR TYPE STRING,
CHGTST TYPE STRING,
CHGMODE TYPE STRING,
DUMMY_ILT_DB TYPE STRING,
PROCS_TEXT TYPE STRING,
PROCESSOR_TEXT TYPE STRING,
START_DATE_ILT TYPE STRING,
START_TIME_ILT TYPE STRING,
END_DATE TYPE STRING,
END_TIME TYPE STRING,
TZONE TYPE STRING,
CRE_DATE TYPE STRING,
CRE_TIME TYPE STRING,
CHG_DATE TYPE STRING,
CHG_TIME TYPE STRING,
MODUS TYPE STRING,
NOTE_CREATED TYPE STRING,
ARCHIVED TYPE STRING,
DUMMY_ILT_DYN TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_ILT_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_ILT_INT_STR-INDLID sy-vline
WA_/SCWM/S_ILT_INT_STR-LGNUM sy-vline
WA_/SCWM/S_ILT_INT_STR-INDLNO sy-vline
WA_/SCWM/S_ILT_INT_STR-PROCS sy-vline
WA_/SCWM/S_ILT_INT_STR-PROCESSOR sy-vline
WA_/SCWM/S_ILT_INT_STR-ENTITLED sy-vline
WA_/SCWM/S_ILT_INT_STR-AAREA sy-vline
WA_/SCWM/S_ILT_INT_STR-STATUS sy-vline
WA_/SCWM/S_ILT_INT_STR-PLANDURA sy-vline
WA_/SCWM/S_ILT_INT_STR-UNIT_T sy-vline
WA_/SCWM/S_ILT_INT_STR-START_TSTAMP sy-vline
WA_/SCWM/S_ILT_INT_STR-END_TSTAMP sy-vline
WA_/SCWM/S_ILT_INT_STR-EXCCODE sy-vline
WA_/SCWM/S_ILT_INT_STR-BUSCON sy-vline
WA_/SCWM/S_ILT_INT_STR-EXEC_STEP sy-vline
WA_/SCWM/S_ILT_INT_STR-NOTE sy-vline
WA_/SCWM/S_ILT_INT_STR-ALLOCTERM sy-vline
WA_/SCWM/S_ILT_INT_STR-CREUSR sy-vline
WA_/SCWM/S_ILT_INT_STR-CRETST sy-vline
WA_/SCWM/S_ILT_INT_STR-CHGUSR sy-vline
WA_/SCWM/S_ILT_INT_STR-CHGTST sy-vline
WA_/SCWM/S_ILT_INT_STR-CHGMODE sy-vline
WA_/SCWM/S_ILT_INT_STR-DUMMY_ILT_DB sy-vline
WA_/SCWM/S_ILT_INT_STR-PROCS_TEXT sy-vline
WA_/SCWM/S_ILT_INT_STR-PROCESSOR_TEXT sy-vline
WA_/SCWM/S_ILT_INT_STR-START_DATE_ILT sy-vline
WA_/SCWM/S_ILT_INT_STR-START_TIME_ILT sy-vline
WA_/SCWM/S_ILT_INT_STR-END_DATE sy-vline
WA_/SCWM/S_ILT_INT_STR-END_TIME sy-vline
WA_/SCWM/S_ILT_INT_STR-TZONE sy-vline
WA_/SCWM/S_ILT_INT_STR-CRE_DATE sy-vline
WA_/SCWM/S_ILT_INT_STR-CRE_TIME sy-vline
WA_/SCWM/S_ILT_INT_STR-CHG_DATE sy-vline
WA_/SCWM/S_ILT_INT_STR-CHG_TIME sy-vline
WA_/SCWM/S_ILT_INT_STR-MODUS sy-vline
WA_/SCWM/S_ILT_INT_STR-NOTE_CREATED sy-vline
WA_/SCWM/S_ILT_INT_STR-ARCHIVED sy-vline
WA_/SCWM/S_ILT_INT_STR-DUMMY_ILT_DYN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.