ABAP Select data from SAP table /SCWM/S_PACK_CONTROLE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_PACK_CONTROLE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_PACK_CONTROLE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the /SCWM/S_PACK_CONTROLE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_/SCWM/S_PACK_CONTROLE TYPE STANDARD TABLE OF /SCWM/S_PACK_CONTROLE, WA_/SCWM/S_PACK_CONTROLE TYPE /SCWM/S_PACK_CONTROLE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: </SCWM/S_PACK_CONTROLE> TYPE /SCWM/S_PACK_CONTROLE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_PACK_CONTROLE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM /SCWM/S_PACK_CONTROLE INTO TABLE IT_/SCWM/S_PACK_CONTROLE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM /SCWM/S_PACK_CONTROLE * INTO TABLE @DATA(IT_/SCWM/S_PACK_CONTROLE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_/SCWM/S_PACK_CONTROLE INDEX 1 INTO DATA(WA_/SCWM/S_PACK_CONTROLE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_/SCWM/S_PACK_CONTROLE ASSIGNING </SCWM/S_PACK_CONTROLE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_PACK_CONTROLE>-RCODE_REQ = 1.
</SCWM/S_PACK_CONTROLE>-DEF_RCODE = 1.
</SCWM/S_PACK_CONTROLE>-NO_PACK_ON_BIN = 1.
</SCWM/S_PACK_CONTROLE>-BUSCON = 1.
</SCWM/S_PACK_CONTROLE>-PRMODE = 1.
ENDLOOP. LOOP AT IT_/SCWM/S_PACK_CONTROLE INTO WA_/SCWM/S_PACK_CONTROLE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_/SCWM/S_PACK_CONTROLE-CDSTGRP_MAT, sy-vline,
WA_/SCWM/S_PACK_CONTROLE-CDSTGRP_HU, sy-vline,
WA_/SCWM/S_PACK_CONTROLE-CHKPACK_DSTGRP, sy-vline,
WA_/SCWM/S_PACK_CONTROLE-CHKPACK_STOPROUT, sy-vline,
WA_/SCWM/S_PACK_CONTROLE-PROCESSOR_DET, sy-vline,
WA_/SCWM/S_PACK_CONTROLE-UNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_PACK_CONTROLE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_PACK_CONTROLE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_PACK_CONTROLE INTO WA_/SCWM/S_PACK_CONTROLE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_PACK_CONTROLE_STR,
RCODE_REQ TYPE STRING,
DEF_RCODE TYPE STRING,
NO_PACK_ON_BIN TYPE STRING,
BUSCON TYPE STRING,
PRMODE TYPE STRING,
CDSTGRP_MAT TYPE STRING,
CDSTGRP_HU TYPE STRING,
CHKPACK_DSTGRP TYPE STRING,
CHKPACK_STOPROUT TYPE STRING,
PROCESSOR_DET TYPE STRING,
UNAME TYPE STRING,
WEIGHT_TOL TYPE STRING,
LOCK_SOURCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_PACK_CONTROLE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-RCODE_REQ sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-DEF_RCODE sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-NO_PACK_ON_BIN sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-BUSCON sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-PRMODE sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-CDSTGRP_MAT sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-CDSTGRP_HU sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-CHKPACK_DSTGRP sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-CHKPACK_STOPROUT sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-PROCESSOR_DET sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-UNAME sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-WEIGHT_TOL sy-vline
WA_/SCWM/S_PACK_CONTROLE_STR-LOCK_SOURCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.